Powered analog input 0
–
10V
Input signal between input and ground. +3V present at B+ pin.
Select “Analog input” in
the application
“Sensor Settings”. Select “Eternal startup time”
and configure ON-time for sensor. External startup time is how long the sensor will be
powered before sampling value. ELT input is internally pulled down and the input
impedance is 7.4 k
Ω
Pulse count (Pull up)
Input signal between input and ground.
Select “Pulse input
(pull up)” in
the
application “Sensor Settings”. ELT input is internally
pulled up by ~50 k
Ω
*.