background image

The Kent Range of Metering Products

T-Probe

For retro-fitting to V100 and V110 meters

I N S T A L L A T I O N   I N S T R U C T I O N S

The brass bodied V100 (Kent PSM) and some versions of the

thermoplastic V110, can be specified with the facility for a magnetically

operated (reed switch) pulsed output, by the retrofitting of a dedicated

probe assembly.

The probe is fitted with a 100

series resistor to protect the reed switch

from power surges and is usually provided with a 5 metre length of

cable, terminating in a sealed flying lead.

Most V100 and V110 meters have the probe location hole

in the body and a driving magnet fitted. V100 or V110

meters without this facility cannot be retro-fitted with 

a T-probe.

Содержание T-Probe

Страница 1: ...gnetically operated reed switch pulsed output by the retrofitting of a dedicated probe assembly The probe is fitted with a 100Ω series resistor to protect the reed switch from power surges and is usually provided with a 5 metre length of cable terminating in a sealed flying lead Most V100 and V110 meters have the probe location hole in the body and a driving magnet fitted V100 or V110 meters witho...

Страница 2: ...his will generate 1 Pulse 0 5 Litre Where there are 3 red rollers 25mm 30mm and 40mm size this will generate 1 Pulse 5 0 Litre Probe Fitting Instructions Remove and discard the plastic protective plug Insert the probe into the socket and align with screw hole Fit the retaining screw through the hole in the probe The reed switch within the probe is self positioning with the screw firmly in place Se...

Страница 3: ...Blue Black and Yellow as the core colours contained within a white outer sheath There are 2 wiring variants available identified as follows Common Loop Back TL1 Product Code RR1LRBX005X Separate Loop Back TL2 Product Code RR1LRTX005X Standard Version For TL1 variant the BLACK and YELLOW cores are the volt free pair The loop back is across RED and YELLOW cores The Blue core can be cut back and disc...

Страница 4: ...ions Personal Protective Equipment Regulations British Standards and other applicable ISO and European Specifications and Codes of Practice as applicable to the intended application of the products Regulations for electrical equipment of buildings published by the Institution of Electrical Engineers Catalogues and product leaflets of this Company or literature which may be obtained by specific req...

Страница 5: ...ments Any instructions specifically advised by the Company and where appropriate with particular reference to information marked on the product The product must only be used in the condition supplied or specified by the Company without modification and for the purpose for which it was designed 3 In accordance with your statutory duties to employees and other persons you are therefore requested to ...