To display the measured values relating to the daily limit, move the cursor to
"Serv."
>
"Volume conversion"
> "per day".
Display
Description
K.Dyc Ø
Mean value K of current day
K.DyØ
Mean value K of last day
C.Dyc Ø
Mean value C of current day
C.Dy Ø
Mean value C of last day
DayB
Day boundary, indicates the begin of the gas day
To display the measured values relating to the daily limit, move the cursor to
"Serv."
>
"Measured values"
> "per day".
Display
Description
T.Dyc Ø
Mean value Temperature of current day
T.Dy Ø
Mean value Temperature of last day
p.Dyc Ø
Mean value p of current day
p.Dy Ø
Mean value p of last day
DayB
Day boundary, indicates the begin of the gas day
9.2.5
Time elapsed since the daily limit
The time elapsed since the daily limit was last exceeded is displayed on the device. In this case, move the
cursor to
"Serv."
>
"Archives" > "TmDBy"
.
9.2.6
Deleting the daily archive
See Chapter 2.4.2 Clear volumes and archives ("Clr.V") or. 2.4.3 Clear archives ("Clr.A").