Maintenance
Press the key combination ENTER
+
One digit of the value flashes.
Move the cursor with the arrow buttons
or
to the digits and change these with the
arrow buttons
or
.
After the value has been entered, press the key combination ENTER
+
in order to
confirm the input. It is possible to abort the entry by pressing the key combination ESC
+
.
To enter the battery capacity, move the cursor to the Serv. tab and via the following path to
the Bat.C value (battery capacity):
Serv.
Batteries
Bat.C
Press the key combination ENTER
+
One digit of the value flashes.
Move the cursor with the arrow buttons
or
to the digits and change these with the
arrow buttons
or
.
When using a battery of the D value, set the Bat.C value to 13.0 Ah.
After the value has been entered, press the key combination ENTER
+
in order to
confirm the input. It is possible to abort the entry by pressing the key combination ESC
+
.
To close the administrator lock, move the cursor to the Admin tab and via the following
path to the St.AL value (administrator lock status):
Admin.
Device settings
Access
St.AL
Press the key combination ENTER
+
"open" flashes.
Move the cursor with the arrow keys
or
to change the value to "closed".
After the value has been entered, press the key combination ENTER
+
in order to
confirm the input. It is possible to abort the entry by pressing the key combination ESC
+
.
7.2.3 Display remaining operating duration of the battery
The calculation of the remaining operating duration is carried out depending on
the consumed capacity (which is measured) and the consumption expected for
the future (which results in the theoretical remaining operation duration). For
that reason, for applications with strong power consumption may result in the
remaining operating duration falling faster than the indication of the remaining
operating duration promises.
A fresh calculation of the remaining operating duration is automatically carried
out after entering a new battery capacity Bat.C (see above). It is not possible to
edit the value.
Move the cursor to the "Serv." tab and via the following path to the value "Bat.R"
(remaining battery operating duration):
Serv.
Batteries
Bat.R
After entering a new battery capacity, in the standard operating case (see
chapter 3.2.1) a value of at least 62 months must be displayed for "Bat.R".
Содержание EK205
Страница 1: ...Operating manual Volume conversion device EK205 ...
Страница 6: ......
Страница 64: ...64 Appendix 9 2 Conformity declarations19 19 IECEx is not available for all device types ...
Страница 65: ...Appendix 65 9 3 Design test certifications 9 3 1 ATEX EC Type Examination Certificat ...
Страница 66: ...66 Appendix ...
Страница 67: ...Appendix 67 ...
Страница 68: ...68 Appendix 9 3 2 IECEx Certificate of Conformity20 20 Not available for all device types ...
Страница 69: ...Appendix 69 ...
Страница 70: ...70 Appendix ...
Страница 71: ...Appendix 71 ...