Installation
4
Page 20 of 38
Safety Instructions
UFM Series 6
4.3.1 DSL / Network Connections (TB2 & J4)
DSL Network / Ethernet connections
Power over Ethernet
Maximum cable core 1.5 mm
2
4.3.2 Outputs / Communication (TB3)
Two configurable opto-coupler outputs, max 30VDC @ 12mA.
Two isolated passive/active 4...20mA analogue outputs, 16 bit
resolution.
Two opto-coupler outputs, max 30VDC @ 12mA (shared with
analogue outputs.)
Two RS232/RS485 (software configurable) ports:
o
Cable: 3 x 2 wire (min 0.5 mm
2
), shielded max. 15m,
max. 2,5 Ohm/wire
o
Programmable up to 38400 bps.
Maximum cable core 1.5 mm2
IS Inputs (optional) (TB4/TB5). For electrical parameters, refer to
Chapter
(p.21)
Two isolated passive/active 4...20mA analogue inputs, 16 bit
resolution.
Maximum cable core 1.5 mm
2
Содержание 6 Series
Страница 1: ...73023465_A_EN i 2016 02 09 Doc 10000050186 ...
Страница 28: ...Page 28 of 38 Safety Instructions UFM Series 6 ...
Страница 30: ...Annex A Control Drawing FM Page 30 of 38 Safety Instructions UFM Series 6 ...
Страница 32: ...Annex B Control Drawing CSA Page 32 of 38 Safety Instructions UFM Series 6 5 ...