background image

 

 

 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 

 

Quick Reference Guide 

 

Issue 1.1  
August 2010 

Cat. #: SMR-3011-0110

 

©2010 Elspec Ltd, All rights reserved. 

All product names are trademarks of their respective companies. 

Shop for Elspec products online at:

1.877.766.5412

www.

PowerMeterStore

.com

Содержание G3500 Series

Страница 1: ...Guide Issue 1 1 August 2010 Cat SMR 3011 0110 2010 Elspec Ltd All rights reserved All product names are trademarks of their respective companies Shop for Elspec products online at 1 877 766 5412 www PowerMeterStore com ...

Страница 2: ...Shop for Elspec products online at 1 877 766 5412 www PowerMeterStore com ...

Страница 3: ...r repair in another country Elspec s warranty obligation is limited at Elspec s option to refund of the purchase price free of charge repair or replacement of a defective product which is returned to Elspec within the warranty period To obtain warranty service contact Elspec directly to obtain return authorization information and then send the product to Elspec with a description of the problem po...

Страница 4: ...on of this Warranty is held invalid or unenforceable by a court or other decision maker of competent jurisdiction such holding will not affect the validity or enforceability of any other provision Notice regarding Proprietary rights This publication contains information proprietary to Elspec Ltd By accepting and using this manual you agree that the information contained herein will be used solely ...

Страница 5: ...eference II 5 III ON SITE SETUP III 1 Step 1 Connect the AC Power Supply III 2 Step 2 Establish a Connection with the Unit III 3 Wired or Wireless Single PC Connection III 3 Integrated Router III 3 Wi Fi Access Point III 4 Step 3 Wire the Voltage and Current Measurement Inputs III 5 Connect Voltage Cords III 5 Attach Current Clamps III 6 Step 4 Configure the Unit III 7 Login to the Internal Websit...

Страница 6: ...ure IV 2 Adding a Node IV 3 Verifying System Time Settings IV 4 Enabling the Node IV 4 Data Export and Reporting IV 5 Templates IV 5 Viewing Downloaded Data with Investigator IV 6 Adding a Node IV 6 Views IV 7 Multi View IV 7 Trend View IV 8 Trend Grid View IV 8 Spectrum View IV 9 Viewing Minimum Maximum and Average Values of a Voltage Harmonics IV 10 CBEMA View IV 10 Zooming In Out IV 11 Tools IV...

Страница 7: ...e Phase with Neutral Single LN V 2 Single Phase without Neutral Single LL V 2 Single Split Phase 2Phase TR V 2 Three Wire Delta Delta 3 Wire V 3 Grounded Delta Delta 3 Wire V 3 Four Wire WYE WYE 4 Wire V 4 Three Wire WYE Delta 3 Wire V 4 Delta High Leg Delta 3 Wire V 5 Delta Open Leg Delta 3 Wire V 5 Shop for Elspec products online at 1 877 766 5412 www PowerMeterStore com ...

Страница 8: ...Shop for Elspec products online at 1 877 766 5412 www PowerMeterStore com ...

Страница 9: ...e of the Art PQSCADA Investigator application helps to explore power quality events zooming in and out on any parameter at High Definition resolution from months to microseconds in mouse click speed and simplicity The Embedded Website is the user interface to the unit Real time parameters can be viewed and the unit configuration can be performed using the website The optional dedicated Tablet PC e...

Страница 10: ...he condition s that lead to the failure Post Processing Elspec s Power Quality Investigator software allows for powerful but simple to use Post processing and report generation Highest Sampling Rate The G4500 3500 SERIES Portable samples all channels simultaneously at the highest sampling rate of 1024 512 samples per cycle for voltage and 256 for Current without the need to set any thresholds or t...

Страница 11: ...rs Type of Analog to Digital converter 16 20 bit 16 20 bit Data and Waveforms Logs Cycle by cycle PQZIP logging Event logs Waveform logs Min max logs for any parameter Timestamps resolution in micro seconds Time SYNC accuracy via LAN Fast Ethernet Link or via GPS PPS 50 100 μs 50 100 μs Storage Capacity Internal Memory 2 GB 32 GB Recording Time depending on selected resolution 3 Months Unlimited P...

Страница 12: ...eter Uncertainty Measuring Range Frequency 10 mHz 42 5 Hz 69 Hz Magnitude of Supply Voltage 0 1 of Udin 10 150 of Udin Flicker 5 of reading 0 2 10 Pst Supply Voltage Dips and Swells Magnitude 0 2 of Udin Duration 1 cycle N A Voltage Interruptions Duration 1 cycle N A Unbalance 0 15 0 5 5 u2 0 5 5 u0 Harmonics IEC 61000 4 7 Class I 10 200 of Class 3 of IEC 61000 2 4 Interharmonics IEC 61000 4 7 Cla...

Страница 13: ...ulation surrounding the connectors and plugs Remove all probes test leads and accessories that are not in use Make sure the instrument is properly grounded through the power cord to protective earth ground Do not apply input voltages above the rating of the instrument as shown on the name plate Do not insert metal objects into connectors and openings Never open instrument s enclosure during operat...

Страница 14: ...ence Guide EAH 4303 5100 Black AC Voltage Cord with Crocodile Clip Fuse 3M EAH 4303 5200 Red AC Voltage Cord with Crocodile Clip Fuse 3M EAH 4303 5300 Blue AC Voltage Cord with Crocodile Clip Fuse 3M EAH 4303 5400 Yellow AC Voltage Cord with Crocodile Clip Fuse 3M EAH 4303 9500 Green AC Voltage Cord with Crocodile Clip 3M EAH 4303 5100 Black DC Voltage Cord with Crocodile Clip Fuse 3M EAH 4303 520...

Страница 15: ...Relay terminal block connector RoHS Compliant TOE 0010 0013 LAN communication cord length 2M EPC 2012 2190 Power Cable for Cont Europe 10A 125V straight 1 8M Black EPC 7012 2190 Power Cable for North America 10A 125V straight 1 8M Black SOA 9045 3001 3000 Amp Flexible Current Clamp Set of 4 Only one power cord is included and will depend on the region to which the shipment is made Other Measuremen...

Страница 16: ...ly 2010 BLACKBOX PORTABLE QUICK REFERENCE GUIDE II 4 Before Getting Started Elspec Controls and Indicators Front Panel Rear Panel Shop for Elspec products online at 1 877 766 5412 www PowerMeterStore com ...

Страница 17: ...0Mb RJ45 Ethernet socket Available only in the G4500 10 LAN2 LCD 10 100Mb RJ45 Ethernet socket 11 PCMCIA Extension slot Available only in the G4500 12 Battery status indicator 13 Operational status indicator 14 External temperature sensor socket 15 Reset to factory defaults button 16 Operation ON OFF switch with indicator 17 L1 voltage presence indicator 18 L2 voltage presence indicator 19 L3 volt...

Страница 18: ...ensor socket 29 Earth Ground reference socket 30 L3 voltage sensor socket 31 I1 L1 current probe socket 32 I2 L2 current probe socket 33 I3 L3 current probe socket 34 I4 Neutral current probe socket 35 IDC Earth current probe socket Available only in the G4500 36 VDC minus probe socket Available only in the G4500 37 VDC plus probe socket Available only in the G4500 38 Main Power supply ON OFF Swit...

Страница 19: ...tion the Downloading and Analyzing Recorded Data on page IV 1 provides detailed explanations of how to work with the powerful yet simple PQSCADA and Investigator software applications Connect the AC Power Supply Establish a Connection with the Unit Wire the Voltage and Current Measurement Inputs Configure the Unit Verify the Measurement Readings Start Stop PQZip Recording Shop for Elspec products ...

Страница 20: ...dicator lights as below Status State Flashing blue Main or auxiliary power applied Battery charging Solid blue Main or auxiliary power applied Battery fully charged Red No main or auxiliary power available Powered by internal battery The unit can run on battery power for up to two hours Also the device can be powered using the Auxiliary DC Voltage Supply please refer to the BLACKBOX User Guide for...

Страница 21: ... connection However the most recommended is a LAN1 option as shown above because of the integrated DHCP server available thru that port When connected a PC will automatically obtain an IP address configuration which allows a seamless connection to the BLACKBOX Portable s internal WEB FTP servers as well as to a router management WEB server Integrated Router The G4500 BLACKBOX Portable not availabl...

Страница 22: ...evice serial number The device serial number is located on the name plate as shown below The Wi Fi link is active when a Wi Fi activity indicator light is flash ing or solid blue There are alternative connection options available For more details please refer to the G4500 BLACKBOX User Guide Shop for Elspec products online at 1 877 766 5412 www PowerMeterStore com ...

Страница 23: ...n the device according to the color codes 2 Attach Crocodile clips from the voltage cords to the measured power source 3 Verify connection with the Presence Indication LEDs as above The LED light illuminates in blue for voltage levels above 10 of the nominal value Make sure that the voltage measurement ground is connected first then neutral and finally the phases Refer Circuit Topologies on page V...

Страница 24: ...l if applicable to its corresponding Current Probe Socket 2 Connect the measurement end of current clamp to the measured power source The current clamps are calibrated from the factory for a specific phase Please make sure that you pay attention to the phase connections The current clamps convert current to low voltage Refer to Circuit Topologies on page V 1 to interface the device with your circu...

Страница 25: ...ult factory IP 169 254 249 247 When the device IP address is unknown use the Elspec Search utility to discover it Please refer to the G4500 BLACKBOX User Guide for details on using Elspec Search to locate the unit Login as Administrator Password 12345 in order to set configuration options The Website is optimized to work with Microsoft Explorer 7 Other web browser applications can limit some funct...

Страница 26: ...tion Operator and Company however it is not required at this time A confirmation window appears Voltage and Frequency From Configuration Voltages Frequency enter the correct nominal values for Voltage and Frequency then click Apply Changes If measuring to PTs then enable the PT ratio and set Primary and Secondary values Shop for Elspec products online at 1 877 766 5412 www PowerMeterStore com ...

Страница 27: ... the correct current nominals then click Apply Changes If measuring using CT s then verify set the CT Primary and Secondary ratios If measuring with mini clamps please verify the Primary and Secondary ratios as well as the Clamp info for accuracy Shop for Elspec products online at 1 877 766 5412 www PowerMeterStore com ...

Страница 28: ...orrect measurement readings of the device we strongly recommend that you verify the voltage and current measurements as well as the phase direction of the current clamps Summary From the Monitoring Summary Verify the DSP Synchronization is On and the Phase order is 123 Shop for Elspec products online at 1 877 766 5412 www PowerMeterStore com ...

Страница 29: ...the device and the power source Monitoring Power From Monitoring Power verify the Active power readings are positive integers If the active power reading in any phase is negative yellow highlight then change the relevant phase from Normal to Reverse in Configuration Currents or reverse the polarity of the current clamp at the power source by changing the direction Generators commonly display a neg...

Страница 30: ...hanges 2 It is recommended to record the starting ending time and date of each measurement set This helps to locate individual measurement sets at a later date 3 After all data measurements have been taken then you need to stop the PQZIP recording Disable PQZIP To Disable PQZIP Recording From Configuration PQZIP Recording select Disable then click Apply Changes We strongly recommend that you verif...

Страница 31: ...sible notification possibilities email SMS and Pop Ups The notification is triggered by events by pre defined or user defined electrical events Analyze the data Using a series of views to see different aspects of it including summaries trends spectral of Volt Amps Hz events harmonics THD Flicker power and energy Multiple device synchronization Elspec s Investigator allows you to view multiple devi...

Страница 32: ...r PC Building a Site Structure The purpose of a Site is to organize the Nodes by a common set of characteristics i e location To add a Site 1 Double click the PQSCADA icon on your desktop to start 2 From the Nodes Sites tab right click Local Computer or selected site then select Add Site 3 Enter configuration values in the Add Site window in our example we assigned PQS Site as the new site name Fo...

Страница 33: ...the PQZip files Parses and stores the data into the correct database Calculates queries in real time For each monitored device a Node must be created To add a Node to the Site 1 Right click PQS Site then select Add Node 2 From the Add Node window Add a Node names Test Node to PQS Site 3 Attach the device to the node using the default assigned IP address 192 168 1 1 for this device Shop for Elspec ...

Страница 34: ...tive therefore we strongly recommend that you verify that all time settings between your system the PQSCADA and Investigator are synchronized To verify system time settings Verify the system time settings Enabling the Node To enable the Node in PQSCADA Right click the Node then click Enable The PQSCADA is now downloading data from the device Shop for Elspec products online at 1 877 766 5412 www Po...

Страница 35: ...mponents you may access the Tasks through either the View or Administrative console The default is View mode 1 From the Tasks Tab right click the Site then select Add Task 2 Follow the Job Selection Wizard to define the Task Configuration Templates Templates are used to define the Events Parameters and Configurations for utilization by different tasks By using templates you can save the time of re...

Страница 36: ...lity Investigator is an innovative tool which helps analyze electrical network anomalies while investigating power quality issues and eventually generate reports according to different PQ Standards such EN50160 Adding a Node From the main menu select File Scan Local Sites then view with Investigator Sometimes the application will take a few minutes to find the Site and Node and for PQSCADA to star...

Страница 37: ...mber of views of any type simultaneously Trend 2 and Events 2 in our example You may also view multiple devices simultaneously synchronized in time This unique feature is useful to identify a common fault between multiple devices at different locations Icon View Type Trend View Events View Spectrum View Summary View Trend Grid View CBEMA View Shop for Elspec products online at 1 877 766 5412 www P...

Страница 38: ...A Trend view is a continuous trend graph of data parameters over time Trend Grid View A trend grid view is simply a tabular representation of the trend view Each measurement point in the table is plotted in graphical format in the Trend View Shop for Elspec products online at 1 877 766 5412 www PowerMeterStore com ...

Страница 39: ...e the Harmonic Min Max values for the given time period one day This is a unique feature because we are measuring harmonics for a given period of time and the display shows the Min Max values measured during the time period As you pass the mouse over a specific harmonic on the graph a message box appears as above displaying all relevant information Shop for Elspec products online at 1 877 766 5412...

Страница 40: ... to view both the Average and the MinMax views of the voltage under investigation CBEMA View The CBEMA Computer and Business Equipment Manufacturers Association is a power quality graph that plots the depth or deviation of voltage dips and overvoltage on the x axis and the duration on the y axix Each event is plotted according to severity as defined by the CBEMA standard Shop for Elspec products o...

Страница 41: ...he resolution the more precise the graph you receive To Zoom In Out From the graph left click the mouse at the beginning of the desired zoom in period drag the mouse across dotted line region then release at the end In the graph below we are examining a voltage dip event that occurred around January 30 2009 The zoom in feature allows us to zoom in to take a closer look at this event from a span of...

Страница 42: ...oltage drop event and the corresponding waveforms during the same time period Tools Once a view is established it is possible to change the view with the tool buttons at the top of the Main Viewing area Icon Tool Toolbar Append Back Back Forward Append Forward Expand Time Previous Time Next Time Frame Favorites Shop for Elspec products online at 1 877 766 5412 www PowerMeterStore com ...

Страница 43: ...e following screens will show how to change the views easily using these tools Each view can be changed according to a pre set time period Append Back Appending back means that you leave the end time intact and move the start time back by a selected amount five minutes in our example Shop for Elspec products online at 1 877 766 5412 www PowerMeterStore com ...

Страница 44: ...ack to shift the current time duration back a specified amount of time five minutes in our example Append Forward Appending forward means that you leave the start time intact and move the end time forward by a selected amount ten minutes in our example Shop for Elspec products online at 1 877 766 5412 www PowerMeterStore com ...

Страница 45: ...ed Data IV 15 Forward You may select Forward to shift the current time duration forward a specified amount of time three minutes in our example Expand Time To expand or zoom out from a view use the Expand Time button Shop for Elspec products online at 1 877 766 5412 www PowerMeterStore com ...

Страница 46: ...yields the three time larger interval as below Previous Time Next Time In order to move back to the previous time selection use the Previous Time button To move in the opposite direction use the Next Time frame button Trend Data Exporting It is possible to export the graphic files in the following formats Shop for Elspec products online at 1 877 766 5412 www PowerMeterStore com ...

Страница 47: ...s option allows you to more clearly identify an area of interest Multiple Panes A graph can contain multiple parameters In order to separate each in order to investigate further it is sometimes easier to separate each parameter into its own pane Shop for Elspec products online at 1 877 766 5412 www PowerMeterStore com ...

Страница 48: ... QUICK REFERENCE GUIDE IV 18 Downloading and Analyzing Recorded Data Elspec A new window is created splitting each parameter L1 L2 and L3 into its own pane Shop for Elspec products online at 1 877 766 5412 www PowerMeterStore com ...

Страница 49: ...kets actually measure Voltage at a low range therefore the risk of electrical shock is minimized The device is designed to serve in virtually any circuit topology configuration The pages to follow will show some of the most popular power topologies with suggested connection diagrams The correct Power Configuration settings appear in parenthesis next to each configuration The available choices from...

Страница 50: ...QUICK REFERENCE GUIDE V 2 Circuit Topologies Elspec Single Phase with Neutral Single LN Single Phase without Neutral Single LL Single Split Phase 2Phase TR Shop for Elspec products online at 1 877 766 5412 www PowerMeterStore com ...

Страница 51: ...BOX PORTABLE QUICK REFERENCE GUIDE July 2010 Elspec Circuit Topologies V 3 Three Wire Delta Delta 3 Wire Grounded Delta Delta 3 Wire Shop for Elspec products online at 1 877 766 5412 www PowerMeterStore com ...

Страница 52: ...ly 2010 BLACKBOX PORTABLE QUICK REFERENCE GUIDE V 4 Circuit Topologies Elspec Four Wire WYE WYE 4 Wire Three Wire WYE Delta 3 Wire Shop for Elspec products online at 1 877 766 5412 www PowerMeterStore com ...

Страница 53: ...KBOX PORTABLE QUICK REFERENCE GUIDE July 2010 Elspec Circuit Topologies V 5 Delta High Leg Delta 3 Wire Delta Open Leg Delta 3 Wire Shop for Elspec products online at 1 877 766 5412 www PowerMeterStore com ...

Страница 54: ...Shop for Elspec products online at 1 877 766 5412 www PowerMeterStore com ...

Страница 55: ...Shop for Elspec products online at 1 877 766 5412 www PowerMeterStore com ...

Страница 56: ...outh Street Freeport IL 61032 U S A Zona Industrial Fase 1 4900 231 Chafe Viana do Castelo Portugal Tel 972 4 6272 470 Tel 1 815 266 4210 Tel 351 258 351 920 Fax 972 4 6272 465 Fax 1 815 266 8910 Fax 351 258 351 607 e mail info elspec ltd com e mail info elspecna com e mail info elspecportugal com Shop for Elspec products online at 1 877 766 5412 www PowerMeterStore com ...

Отзывы: