Please read and understand these instructions before starting work. 

Please leave this leaflet with the user following installation.

PACK CONTENTS

Heater, fixing screws and plugs, 

installation and user instructions.

   

WARNING

This Instantaneous Hand Wash must only 

be installed by qualified persons.

36006228  Issue 4.

 

Elson 3kW Manual Handwash

Installation and User Instructions
Model: EHW3

Содержание EHW3

Страница 1: ...is leaflet with the user following installation PACK CONTENTS Heater fixing screws and plugs installation and user instructions WARNING This Instantaneous Hand Wash must only be installed by qualified persons 36006228 Issue 4 Elson 3kW Manual Handwash Installation and User Instructions Model EHW3 ...

Страница 2: ...ater heater Particular attention should be paid to the section headed SAFETY Section 2 0 p 3 Following installation and commissioning the operation of the heater should be explained to the user Section 7 0 p 14 and these instructions left with them for future reference This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilitie...

Страница 3: ...lies with the requirement of EN 60335 2 35 Complies with European Community Directives CE Supplier s name or trade mark Elson Supplier s model identifier EHW3 The declared load profile XXS The water heating energy efficiency class of the model A The water heating energy efficiency in 38 6 The annual electricity consumption in kWh 478 Daily fuel consumption Qlec in kWh 2 200 Specific precautions th...

Страница 4: ...are safe and without risk provided they are installed used and maintained in good working order in accordance with our instructions and recommendations 2 2 Please read and understand these instructions before starting work and retain them for later use 2 3 DO NOT operate the appliance if it is frozen or suspected of being frozen See fault finding table p 15 2 0 SAFETY 1 0 INTERNAL COMPONENTS Therm...

Страница 5: ...levant requirements of The appropriate Building Regulations either The Building Regulations The Building Regulations Scotland or Building Regulations Northern Ireland The Water Fittings Regulations or Water Byelaws in Scotland CAUTION 2 12 It is recommended that persons who may have difficulty understanding or operating the controls should not be left unattended whilst washing hands Special consid...

Страница 6: ... appliance must be earthed 2 23 Fuses do not give personal protection against electric shock To enhance electrical safety a 30mA residual current device RCD should be installed in all electric handwash circuits This may be part of the consumer unit or a separate unit 2 24 Ensure that all terminal block connections are sufficiently tight 2 25 Switch off appliance immediately and isolate if water ce...

Страница 7: ... avoid damaging the appliance If in doubt the pressure should be checked taking account of other services from the same water supply which could cause the pressure to fall below the minimum The water supply can also be taken from a cold water storage cistern provided there is a minimum head of 10m above the appliance 3 3 If the handwash is operated outside of the stated pressure parameters it may ...

Страница 8: ...re sufficient for the rated input of your appliance Please refer to the rating label within the appliance 3 10 A minimum heat resistant cable size of 1 5mm should be used The handwash can be connected in two different ways 1 Via a fused and switched connection unit taken as a spur from a 13amp ring main 2 As a separate circuit taken directly from a spare way in a consumer unit In each case a doubl...

Страница 9: ...umer unit A qualified electrician should install the new consumer unit It may be necessary to contact your electrical supplier to upgrade your supply CAUTION 3 13 To enhance electrical safety a 30mA residual current device RCD should be installed in all electric handwash circuits This may be part of the consumer unit or a separate unit DO NOT use a rewireable fuse instead use a suitably rated mini...

Страница 10: ...ace This allows removal for servicing 4 5 The control knob is an integral part of the cover do not attempt to remove it 4 0 CONSIDERATIONS BEFORE FITTING 4 6 Position the unit above the basin so that the spray will be contained within the basin and at a convenient height for hand washing see Figure 4 opposite 4 7 A clearance of at least 130mm above and below the unit should be allowed for access t...

Страница 11: ... 3 Unscrew the retaining screws and lift the cover from the back plate see Figure 7 below 5 0 FITTING INSTRUCTIONS 5 4 Fit the outlet spout DO NOT over tighten finger tight will be sufficient see Figure 8 above 5 5 After choosing the correct site for the handwash use the backplate as a template and mark the two fixing holes see p 9 BEWARE OF CABLES AND PIPES WHICH MAY BE BURIED IN THE WALL 5 6 Dri...

Страница 12: ...p 12 5 10 Decide where to connect the cold water mains feed to the handwash Ensure that the pipe you have selected is not a gas pipe or a hot water pipe Chrome and stainless steel pipe is not recomended 19 5 74 29 86 196 5 151 235 Cable Clamp Inlet water connection Terminal Block Rear entry access area for electricity and inlet water supply Figure 9 Unit layout Dimensions mm ...

Страница 13: ...ntial to flush the pipe in order to clear debris particles of solder and swarf see Figure 12 opposite 5 16 Turn the water off after flushing using the isolating stop valve 5 17 Connect the cold water supply pipe to the inlet of the handwash this is a push fit see Figure 11 above 5 18 Fit top and bottom screws and secure the backplate to the wall ensuring that it is level 5 19 Close the handwash fl...

Страница 14: ...6 7 Strip the outer sheath of the cable to a point about 5mm above the clamp thus ensuring that the cable is clamped across its outer sheath 6 8 Strip the insulation from the cores and make connections see Figure 13 below 6 0 ELECTRICAL CONNECTIONS 6 9 Make sure that all the terminal block screws are sufficiently tight 6 10 Refit the clamp bar FITTING COVER 6 11 Fit outlet spout if required see 5 ...

Страница 15: ...ds for a smoth flow of water to be obtained whilst any air is being dispersed from the handwash 7 3 Stop the water flow by rotating the control knob clockwise 7 4 Turn on the electrical supply at the isolating switch 7 5 Rotate the control knob half a turn anti clockwise After approximately 15 seconds the water will start to heat 7 6 To obtain warmer water turn the control knob clockwise and for c...

Страница 16: ...THE HANDWASH C Spout blocked Clean sprayplate see 9 2 p 16 D Filter blocked Clean filter A Water control knob at Turn knob clockwise until temperature is wrong setting comfortable B Water flow too high Turn knob clockwise until temperature is comfortable C Electricity off Turn on electricity at isolating switch D Poor flow Check inlet pressure A Temperature control knob Turn knob fully anticlockwi...

Страница 17: ...the handwash IMPORTANT 9 2 IT IS MOST IMPORTANT TO KEEP THE SPRAYPLATE CLEAN IN ORDER TO MAINTAIN THE PERFORMANCE OF THE HANDWASH The hardness of the water will determine the frequency of cleaning 9 0 MAINTENANCE Figure 14 Cleaning sprayplate Sprayplate To remove sprayplate unscrew anticlockwise using a coin Ensure all holes in sprayplate are clear It is recomended to soak the sprayplate overnight...

Страница 18: ...btained DO NOT REPLACE WITH PARTS NOT RECOMMENDED BY ELSON AS THIS WILL INVALIDATE YOUR GUARANTEE AND MAY RENDER THE INSTALLATION DANGEROUS DESCRIPTION CODE NO 1 Heat Exchanger Assembly 3 1kW 95 608 003 2 Spout 3 95 604 002 3 Cut out 3 1kW 95 612 029 4 Cut out 3 1kW one shot 95 612 031 5 Valve Pressure Switch Assembly 3 1kW 95 605 052 6 Control Knob 95 605 055 7 Neon Assembly 95 615 023 8 Micro sw...

Страница 19: ...has been regularly maintained as detailed in the Installation and User Instructions 4 The appliance has been used only for heating potable water The appliance is not guaranteed against damage by frost and the inner container with integral heating element is not guaranteed against excessive scale build up This guarantee in no way affects the statutory rights of the consumer The policy of Elson is o...

Страница 20: ...rlow Essex CM19 5BT Tel 0845 0553811 E mail sales ewh co uk SPD Special Product Division Units 9 10 Hexagon Business Centre Springfield Road Hayes Middlesex UB4 0TY Tel 020 8606 3567 Parts Center Tel 0344 292 7057 www partscenter co uk Newey Eyre Unit 3 5 Wassage Way Hampton Lovett Ind Estate Droitwich Worcestershire WR9 0NX Tel 01905 791500 Fax 01905 791501 UK Spares Ltd Unit 1155 Aztec West Almo...