System XS 

XS MSG2-AP Motor Control Unit

XS 1B-D Control Unit

XS 2B Double Control Unit

Installation and Operation

Содержание XS 1B-D

Страница 1: ...System XS XS MSG2 AP Motor Control Unit XS 1B D Control Unit XS 2B Double Control Unit Installation and Operation...

Страница 2: ...e batteries 19 Initial start up 20 Procedure 20 Configuring and deleting wireless connections 20 Wireless connection between motor control unit and weather station 21 Wireless connection between motor...

Страница 3: ...control unit 52 The XS 1B D control unit with display 53 Assigning buttons and weather data screen display icons 53 Brightness and wind speed displays 54 Using the buttons 55 Querying service data 55...

Страница 4: ...3 The XS system Connectivity installation commissioning and basic settings...

Страница 5: ...automatic parameters for all individual drives The wireless based XS system is easy to install without any dirt or waste of time as there is no need to lay cables in the building The control units wo...

Страница 6: ...inds only or for windows only The motors receive your automatic commands centrally from the weather station and can be individually and manually actuated using the XS 2B double control unit Required e...

Страница 7: ...t on the motor control unit Setting the automatic functions for all drives using the Solexa Arexa controls see Solexa Arexa manual The described situation only allows the setting of a shade and or win...

Страница 8: ...onfigured to the motor control unit in order to be able to actuate the drives M2 M3 from elsewhere in the room Required equipment Solexa or Arexa control set from software version 3 2 XS MSG2 AP motor...

Страница 9: ...to the motor control unit Configuring the control units to the motor control unit Basic set up of the drives to the motor control unit using the respective XS 1B D control unit with display Setting th...

Страница 10: ...oper alteration or non observance of the operating instructions will void any warranty or guarantee claim After unpacking the devices shall be checked immediately for any possible mechanical damage Th...

Страница 11: ...supply an emergency generator with appropriate switching from the mains network shall also be installed on site for emergency use Settings saved in the software motor control unit and control units wi...

Страница 12: ...he weather station depending on the rain amount and outdoor temperature Please also bear in mind that in the event of a power failure and rainfall external awnings will not be automatically retracted...

Страница 13: ...on XS control unit battery operated Wireless communication Weather station XS MSG2 AP motor control unit Mains Motor Mains Left motor Right motor 230V AC mains power supply Motor Motor Motor Control u...

Страница 14: ...for drives Left and Right connections Parallel switching of further drives from a single connection point is possible Check whether a group control relay is required by the motor manufacturer Group co...

Страница 15: ...if available the technical specifications Run the power supply and drive connection cable through the grommets and connect the voltage L1 N PE and Left and Right drives PE N Up Down to the terminals d...

Страница 16: ...ntrol relay for 2 drives max 1000 Drive group with a total output of less than 1000 Watt Motors with or with no integrated group control relay Drive group with a total output of less than 1000 Watt Mo...

Страница 17: ...lled and used in dry interior spaces Relative air humidity must not exceed 80 Avoid condensation Rear view and drill sketch All values in mm may vary due to technical requirements Inserting the batter...

Страница 18: ...ntrol unit is battery powered and communicates wirelessly with the motor control unit Avoid selecting an installation position in direct sunlight as this will result in incorrect indoor temperature me...

Страница 19: ...18 Rear view and drill sketch All values in mm may vary due to technical requirements Dimensions in mm...

Страница 20: ...a screwdriver directly into the slot Check that the polarity of the batteries is correct Two commercially available AA type Mignon LR6 batteries 1 5 V or rechargeable batteries 1 2 V are required Clo...

Страница 21: ...ons Wireless connections may only be configured by a professional electrician as the button for configuring and deleting these is located inside the housing The wireless connections between the indivi...

Страница 22: ...al operating commands every 5 seconds This transmission is indicated by a brief flash of the LED within the weather station Activate the motor control unit configure delete mode for the weather statio...

Страница 23: ...r control unit stop flashing and the control unit is then configured XS MSG2 AP configure delete button Press for longer than 6 secs The LEDs on the motor control unit stop flashing All wireless conne...

Страница 24: ...e delete button Press briefly three times The left hand LED is now on and the mode for configuring deleting an XS 1B D control unit on the left channel is activated Configuring a control unit with dis...

Страница 25: ...Control unit set up button Press briefly once The control unit is now configured for the left channel and the LED on the motor control unit is off After configuring the wireless connection you can pro...

Страница 26: ...d Down cables in the motor control unit Wireless connection between right hand channel of motor control unit and control unit with display XS MSG2 AP XS 1B D It is possible to configure an XS 1B D con...

Страница 27: ...s been configured Control unit set up button Press for min 3 secs You are in Automatic settings when the screen indicates Control unit set up button Press for min 3 secs You are in Basic settings when...

Страница 28: ...ally to Step 2 of the basic settings Select drive type Please refer to the following chapter Basic settings from 2 Drive types onwards Should you want to complete the basic settings at a later time pr...

Страница 29: ...less connection between motor control unit and control unit with display 2 Type of drive to be controlled shades or window 3 Single or parallel operation of the drives 4 Operating position 5 Save Acce...

Страница 30: ...pressing the button The changes which have been made will not then be saved If no button is pressed in Basic settings for 5 minutes the screen will automatically switch to display the temperature Any...

Страница 31: ...ol unit with display To implement the basic settings or make changes skip the configuration step by pressing to confirm the displayed The display screen jumps automatically to the next step 2 Drive ty...

Страница 32: ...p when these are drives of the same type The motors then actuate in parallel and only one XS 1B D control unit is required The question regarding the parallel actuation of the drives only appears when...

Страница 33: ...Automatic mode For venetian blinds the opening angle of the slats can also be set reversing For windows Arexa individual positions can be set up to which the automation opens them Press the button un...

Страница 34: ...no shade is provided First fully close the window using the button Then press the button to go to the next step 4 2 Setting a desired position The prompt Close will appear for a shade and Open for a...

Страница 35: ...d Then press the button to complete the setting of the operating position 5 Saving the basic settings At the end of the basic settings Save will prompt you whether you want to save the settings you ha...

Страница 36: ...no weather station is configured in the system no outdoor temperature wind or brightness values are displayed The control unit cannot be switched to Automatic mode Manual operation is still however po...

Страница 37: ...36...

Страница 38: ...37 Setting the automatic XS 1B D control unit and manual operation of the drives...

Страница 39: ...r failure Once the power supply is restored the control system will be set to automatic mode The control unit and the motor control unit may no longer be manually accessed in the event of any disconne...

Страница 40: ...se also bear in mind that in the event of a power failure and rainfall external awnings will not be automatically retracted if no emergency generator is installed Note that sun protection equipment ra...

Страница 41: ...t parameter to be set brightness can then be seen When no weather station is configured on the system Error is displayed instead of the first parameters and no automatic settings can be applied You ca...

Страница 42: ...yed in Kilolux kLux The value 1 kLux is reached already with an overcast sky at 20 kLux the sun starts being visible and 100 kLux is reached during a cloudless sky at midday The default setting for br...

Страница 43: ...es can thus react rapidly to the sun Adjust the value by pressing higher and lower Then press to proceed to set the next parameter C Retraction delay After completing the setting for extension delay y...

Страница 44: ...or temperature guard You can reach the settings by pressing once again when 5 C is displayed Then press to proceed to set the next parameter E Outdoor temperature guard After setting the indoor temper...

Страница 45: ...n function The wind alarm protects shades which are mounted outdoors from damage If the set wind value is exceeded the awnings or blinds are retracted and manual operation is disabled Wind speed is en...

Страница 46: ...shades are automatically retracted and manual operation is disabled The rain alarm remains active for 5 minutes If further rainfall is detected within these 5 minutes the alarm time will be restarted...

Страница 47: ...eter to be set indoor temperature can then be seen When no weather station is configured on the system Error is displayed instead of the first parameter and no automatic settings can be applied You ca...

Страница 48: ...this value is exceeded the Automatic function opens the window unless the outdoor temperature guard value drops below limit see the next parameter The default setting is 25 C Adjust the value by pres...

Страница 49: ...h off the outdoor temperature guard You can reach the settings by pressing once again when 20 C is displayed Then press to proceed to set the next parameter C Wind alarm After setting the outdoor temp...

Страница 50: ...you now need to select whether to switch the rain alarm on or off The rain alarm protects the fixtures from damage When it rains the window is automatically retracted and manual operation is disabled...

Страница 51: ...50 Press the button to save your entries and return to the weather data screen Press to exit without saving any of your automatic settings...

Страница 52: ...s No Shade B Shading when brightness exceeds kLux Extension time delay Min Retraction time delay Min Shade when indoor temperature exceeds C Outdoor temperature guard below C Wind alarm from m s Rain...

Страница 53: ...second allows the drive to be precisely positioned When the button is pressed for longer than 1 second the drive will independently move to its end position Further pressing of either of the arrow but...

Страница 54: ...row as well as the function mode automatic or manual battery status and current alarm messages for rain or wind Weather data is updated once per minute as well as upon any button press Outdoor temper...

Страница 55: ...disabled The wind protection function can be configured and switched off in the automatic function settings for example for indoor awnings Brightness and wind speed displays When the temperature is d...

Страница 56: ...nual operation using the or buttons the control system is in manual mode The automatic functions are then switched off although the rain and wind alarms are still active Press the button to once again...

Страница 57: ...en a drive can be manually actuated using multiple control units it is the last received command that is always being performed This means that the operating command of a control unit is interrupted w...

Страница 58: ...57 Service...

Страница 59: ...wind 5 5 7 9 19 5 28 4 4 11 16 Fresh wind 8 0 10 7 28 5 38 5 5 17 21 Very fresh wind 10 8 13 8 38 6 49 7 6 22 27 Strong wind 13 9 17 1 49 8 61 5 7 28 33 Very strong wind 17 2 20 7 61 6 74 5 8 34 40 St...

Страница 60: ...ess and wind speed values error messages can be displayed onscreen in the weather data display BATTERY fault Only the battery is displayed no other icons or values Manual operation is possible Cause T...

Страница 61: ...ion between the weather station and the control unit is described in chapter Basic settings 1 Wireless connection motor control unit control unit Troubleshooting should only be performed by trained sp...

Страница 62: ...ing should only be performed by trained specialist personnel You shall therefore please contact your installer Technical specifications The wireless frequency used is 868 2 MHz The following standards...

Страница 63: ...x 1 2 V 2 AA Mignon LR6 rechargeable batteries Dimensions approx W 103 mm H 48 mm D 33 mm Ambient temperature 10 50 C Air humidity max 80 rH avoid condensation XS 1B D technical specifications Operati...

Страница 64: ...lsner Elektronik GmbH Steuerungs und Automatisierungstechnik Herdweg 7 D 75391 Gechingen Germany Phone 49 0 70 56 93 97 0 Fax 49 0 70 56 93 97 20 info elsner elektronik de http www elsner elektronik d...