background image

P03/3 Weather Station

2

P03/3 Weather Station

 • Version: 07.06.2021 • Technical changes and errors excepted. • Elsner Elektronik GmbH • Sohlengrund 16 • 75395 Ostelsheim • Germany • www.elsner-elektronik.de • 

Technical Service: +49 (0) 7033 / 30945-250

so as 

not to pull off the wire

 connecting the PCB in the bottom part with the rain

sensor in the cover (wire with push-connector). 

Push the connecting cable through the rubber seal on the bottom of the weather
station and connect the power and data cables to the terminals provided for this
purpose. The supply cable to the weather station should be a maximum of 30 m
long. The connection is by typical telephone cable (J-Y(ST)Y 2 × 2 × 0.8).

The connection cable must be plugged in between the cover and circuit board.

2.2.4. PCB Layout

Set jumper:

Please reboot the system after the setting of the jumper!

2.2.5. Mounting the sensor

Close the housing by putting the cover back over the bottom part. The cover must
snap in on the left and right with a definite “click”.

To remove it, the sensor can be simply pulled upwards out of the mount, against
the resistance of the fastening.

2.3. Notes on mounting and commissioning

Do not open   weather station if water (rain) might ingress: even some drops might
damage the electronic system. 

Observe the correct connections. Incorrect connections may destroy the weather
station or connected electronic devices. 

Please take care not to damage the temperature sensor (small blank at the bottom
part of the housing.) when mounting the weather station. Please also take care not
to break away or bend the cable connection between the blank and the rain sensor
when connecting the weather station.

Remove all existing protection labels after installation.

The correct wind value may only be supplied about 30 seconds after the supply
voltage has been connected.

2.4. Maintenance of the weather station

WARNING!
Risk of injury caused by components moved automatically!

The automatic control can start system components and place people
in danger.

Always isolate the device from the mains for servicing and 
cleaning.

The device must regularly be checked for dirt twice a year and cleaned if necessary.
In case of severe dirt, the sensor may not work properly anymore.

ATTENTION

The device can be damaged if water penetrates the housing.

Do not clean with high pressure cleaners or steam jets.

3.

Disposal

After use, the device must be disposed of or recycled in accordance with the legal
regulations. Do not dispose of it with the household waste!

Control model

Jumper position

WS1000 Touch

no jumper

All other models up to production year 2001

jumper at position (a)

All other models from production year 2002 on

jumper at position (b)

Fig. 12: Overview PCB
1 Socket for connect-

ing cables to 
rain sensor in hous-
ing cover

2 Connection plug

1: +24 V DC | 2: GND | 
3: Data (massive ca-
ble up to 0.8 mm²) 

3 Control LED GPS re-

ceiver

4 Socket for jumper

1

2

3

4

a

b

Fig. 13 

Make sure the cover and bottom part 
are properly snapped together! This 
picture is looking at the closed sensor 
from underneath.

Fastening

Fig. 14

Push the housing from above into the 
fastened mount. The bumps on the 
mount must snap into the rails in the 
housing.

Fig. 15
After installation, remove the "distan-
ce" sticker on the top of the cover.

Отзывы: