background image

EN

CasaConnect KNX

Building Control Center

Article number 71200

Installation, setting, operation

Содержание 71200

Страница 1: ...EN CasaConnect KNX Building Control Center Article number 71200 Installation setting operation...

Страница 2: ......

Страница 3: ...3 1 The manual menu 20 Examples of manual pages 21 Key functions and display fields 22 Info icons 23 2 3 2 Group keys 26 2 3 3 CasaConnect KNX App 26 2 3 4 Navigate in the system menu 27 2 4 Internet...

Страница 4: ...data 50 4 3 8 Function blocks 52 Block A 52 Block B 55 Block C 62 4 4 Symbol overview 65 5 Basic settings in the Control Center 75 5 1 Procedure 76 5 2 The Set screen menu 76 5 2 1 KNX settings 77 5...

Страница 5: ...interface KNX interface 102 License 102 6 Automatic 103 6 1 Procedure 104 6 2 Set automatic mode 104 6 2 1 Safety information about automatic and alarm functions 105 Power outage maintenance work etc...

Страница 6: ...on settings 126 Set automatic mode 126 6 4 4 Set temperature regulator 130 6 4 5 Set light automatic mode 130 7 Tables maintenance 133 7 1 Maintenance and care 134 7 2 Units for sun and wind 134 7 3 D...

Страница 7: ...ous situation which will lead to death or severe injuries if it is not avoided WARNING indicates a potentially hazardous situation which may lead to death or severe injuries if it is not avoided CAUTI...

Страница 8: ...6 Clarification of signs...

Страница 9: ...7 Description CasaConnect KNX Control Center Version 13 09 2021 Technical changes and errors excepted 1 Description...

Страница 10: ...on SD card backup of the settings Integrated loudspeaker 4 tweeters 1 broadband loudspeaker 24 Scenes for calling up individually set actuation positions and switching conditions With a scene multipl...

Страница 11: ...ness for sun protection Location Optional for sun protection manual input possible on the device Wind direction Optional for facade control if there is a wind alarm Indoor room temperature Optional fo...

Страница 12: ...arm messages such as water leaks Temperature floating point Automatic functions of the motors and devices Automatic functions for windows sliding roofs Open from a selectable indoor temperature Open f...

Страница 13: ...below a selectable outdoor temperature Wind alarm Retract if a selectable wind speed is exceeded Rain alarm Retract for precipitation Automatic functions for blinds Close according to brightness and...

Страница 14: ...to the CO2 content of the room only with CO2 sensor Ventilation according to the VOC content of the room only with VOC sensor Winter switching Supply air is closed below a selectable outdoor temperatu...

Страница 15: ...witch sockets or a dou ble socket Protection class IP20 Size Display front approx 279 185 W H mm Installation depth approx 30 mm Display resolution 1280 800 pixels Weight approx 1 2 kg Ambient tempera...

Страница 16: ...14 Description CasaConnect KNX Control Center Version 13 09 2021 Technical changes and errors excepted...

Страница 17: ...15 Operation CasaConnect KNX Control Center Version 13 09 2021 Technical changes and errors excepted 2 Operation...

Страница 18: ...e last active alarm messages In addition the start button for the slide show appears here as soon as an SD card with pictures is loaded Menu left links start menu In the menu on the left hand side you...

Страница 19: ...licable the display pages can be scrolled through using the arrow in the lower area When navigating in the settings submenus the functions parameters are displayed and set here Bottom navigation menu...

Страница 20: ...nges Snow With a precipitation message and temperatures under 3 C it snows Night Light intensity Brightness in lux lx or kilolux klx Direction Compass direction azimuth in degrees Height Elevation abo...

Страница 21: ...limit windows Indoor data You can set which room data should be displayed e g if multiple sensors are connect ed System Set screen Weather display 5 2 6 Weather display Page 86 Outside air data second...

Страница 22: ...anual menu button So that a motor device is displayed in as a favourite the display has to be activated in the setting Manual menu in the installation settings You can change the display sequence in t...

Страница 23: ...play sequence in the manual menu here System Set screen Manual page 5 2 5 Manual page Page 85 As soon as a subject group has been activated motors and devices are no longer displayed in the manual men...

Страница 24: ...ors excepted Blind after manual movement Dim lights to automatic mode Key functions and display fields Up down keys The keys Up and Down have a timer automatic Position Info Sliding bar position Selec...

Страница 25: ...n automatic Page 85 In addition an automatic reset can be activated in the automatic settings of each motor group and each device both at a fixed time and after a manual operation You can access these...

Страница 26: ...ns for different functions Icons for shades Wind alarm Manual operation locked Rain alarm Manual operation locked Frost alarm Manual operation locked Block active E g ventilation prevented because of...

Страница 27: ...and extension delay has not yet expired CO2 VOC value too high Ventilation active Humidity too high Ventilation active Outside temperature too high No ventilation Outside temperature too low No ventil...

Страница 28: ...CasaConnect KNX App is available for Android and for iOS free of charge in the respective App stores Install the App on the mobile device As soon as the mobile device and CasaConnect KNX are in the s...

Страница 29: ...If two CasaConnect KNX control centers are installed in the building they must be connected to different WLAN networks so that App control is possible 2 3 4 Navigate in the system menu All settings f...

Страница 30: ...circle which takes you back directly to the start page 2 4 Internet browser The CasaConnect KNX Control Center has a browser for accessing internet pages on the WorldWideWeb Music and video streaming...

Страница 31: ...on of 1280 800 pixels Colour intensity 24 bit or 16 bit If picture data is saved on the card the Slide show button is displayed on the right of the upper menu bar with which you can directly start it...

Страница 32: ...30 Operation CasaConnect KNX Control Center Version 13 09 2021 Technical changes and errors excepted...

Страница 33: ...31 Installation and commissioning CasaConnect KNX Control Center Version 13 09 2021 Technical changes and errors excepted 3 Installation and commissioning...

Страница 34: ...n saver network connection access code updates etc can be made at any time in the System System settings menu See chapter 5 3 System setting on page 91 5 The Automatic functions have to be adjusted in...

Страница 35: ...ng components System parts may start automatically as a result of the automatic controls and can put people in danger People must not enter the movement range of motorised moving parts If staying outs...

Страница 36: ...n location The device may only be installed and operated in dry indoor rooms Avoid condensation 3 1 7 Preparing the control unit The CasaConnect KNX can be installed in 2 standard sockets however a do...

Страница 37: ...unit take care with the loudspeaker 3 This is magnetic and connected with sensitive cables Step 3 Support plate as drill template Display from above Detail view Notices and mounts of the dis play uni...

Страница 38: ...r maintenance the covers can be carefully levered out in order to gain access to the screws Pass all connection cables through the top socket and the top opening of the support plate Step 4 Support pa...

Страница 39: ...result If applicable allow to dry before commissioning After installation cabling of the system and checking all connections switch on the bus and auxiliary power The control center start and the disp...

Страница 40: ...ally when the time date are re ceived otherwise the time can be set manually The time zone and location must also be set System System setting Settings Time and date 5 3 1 Settings Enter time and date...

Страница 41: ...39 Basic settings in the ETS CasaConnect KNX Control Center Version 13 09 2021 Technical changes and errors excepted 4 Basic settings in the ETS...

Страница 42: ...Service Reset 4 2 KNX transmission protocol Abbreviations Flags C Communication R Read W Write T Transmit U Update 4 2 1 List of all communication objects 1 69 General objects sensor data display sett...

Страница 43: ...nput Out put SK 1 17 DPT_Trigger 1 Bit 21 Central 4 Input Out put SK 1 17 DPT_Trigger 1 Bit 22 Call up scene Input Out put SK 18 1 DPT_SceneControl 1 Byte 30 Outside air temperature C Input SK 9 1 DPT...

Страница 44: ...t SK 1 1 DPT_Switch 1 Bit 51 Precipitation Input SK 1 5 DPT_Alarm 1 Bit 52 Precipitation malfunction Input SK 1 1 DPT_Switch 1 Bit 53 Precipitation volume l h Input SK 9 26 DPT_Rain_Amount 2 Bytes 54...

Страница 45: ...ay brightness Input Out put SK 5 1 DPT_Scaling 1 Byte Block channel Object no Block channel Object no A 1 70 82 A 11 200 212 A 2 83 95 A 12 213 225 A 3 96 108 A 13 226 238 A 4 109 121 A 14 239 251 A 5...

Страница 46: ...93 A 58 811 813 A 49 694 706 A 59 824 836 A 50 707 719 A 60 837 849 Block channel Object no Block channel Object no A 61 850 862 A 71 980 992 A 62 863 875 A 72 993 1005 A 63 876 888 A 73 1006 1018 A 6...

Страница 47: ...bject no Block channel Object no B 41 1270 1273 B 51 1310 1313 B 42 1274 1277 B 52 1314 1317 B 43 1278 1281 B 53 1318 1321 B 44 1282 1285 B 54 1322 1325 B 45 1286 1289 B 55 1326 1329 B 46 1290 1293 B...

Страница 48: ...97 1494 1497 B 88 1458 1461 B 98 1498 1501 B 89 1462 1465 B 99 1502 1505 B 70 1466 1469 B 100 1506 1509 Block channel Object no Block channel Object no B 101 1510 1513 B 111 1550 1553 B 102 1514 1517...

Страница 49: ...ng read triggered alarm up down Input SK 1 7 DPT_Step 1 Bit 1985 Alarm monitoring trig gered alarm name Output L K 16 0 DPT_String_ASCII 14 Bytes 1986 Intern ready to switch live Output L K 1 1 DPT_Sw...

Страница 50: ...ons A time signal can therefore either be provided by the KNX system for example this can come from a weather station with GPS receiver or can be entered manually in the CasaConnect KNX Control Center...

Страница 51: ...view on page 65 The icon can also be selected subsequently at the control center System Set screen Alarm Alarm obj 1 3 Channel icon Alarm Page 77 Central functions Here you can set whether you want to...

Страница 52: ...wind or rain protection then receive the command via the bus to move to the safe position No data time CasaConnect KNX does not receive any time information from the bus after starting resetting Use...

Страница 53: ...wind and rain protection receive the command via the bus to move to the safe position The normal automatic operation is only started again when the following weather data has been received Wind value...

Страница 54: ...nels serve to connect control and display elements sensors and alarms Type C channels serve as temperature regulator extension Block A The menu item only appears if it is selected for function blocks...

Страница 55: ...d be sent The minimum and maximum colour temperature should correspond to the colour tem perature range of the lights The HCL controls are set on the CasaConnect KNX display 6 4 5 Set light automatic...

Страница 56: ...ol is used 1 50 5 or Colour temperature change larger in Kel vin only if HCL control is used 1 500 50 Object type for RGB separate for red green blue together for red green blue Use separate brightnes...

Страница 57: ...he screen e g in order to change the limit values set in the ETS 4 Sensors The sensors set here can be selected on the screen important for auto matic functions Enter a name for the channel and select...

Страница 58: ...er with mathematical sign Display 16bit floating point Display 32bit counter without mathemati cal sign Display 32bit counter with mathematical sign Display 32bit floating point Display text Input 1 0...

Страница 59: ...con displays on the screen Type of output Display 1 0 Type of output Display icon Value range 1 has the highest priority If value ranges overlap the one with the highest priority is used Use actuation...

Страница 60: ...Type of output Display 16bit floating point Display value Value of bus a b Type of output Display 32bit counter without mathematical sign Type of output Display 32bit counter with mathematical sign Ty...

Страница 61: ...priority is displayed Type of output Input scene Type of output Input 8bit value 0 255 Transmission behaviour press 1 release 0 press 1 release nothing press 0 release 1 press 0 release nothing press...

Страница 62: ...alue only if value can be set via display 0 100 Maximum value only if value can be set via display 0 100 Unit Free text Value can be adjusted via display No Yes Start value 0 360 Minimum value only if...

Страница 63: ...an be set via display 2147483648 2147483647 Unit Free text Value can be adjusted via display No Yes Start value 0 4294967295 Minimum value only if value can be set via display 0 4294967295 Maximum val...

Страница 64: ...data for each connected temperature regulator can be transmitted with these 15 channels I e the setpoints for an independent temperature regulator connected via the KNX bus can be specified with the C...

Страница 65: ...switching between eco and standby mode and the two others are used to activate comfort mode or frost heat pro tection mode The comfort object then blocks the eco standby object and frost heat protecti...

Страница 66: ...eople are absent If setpoints are set separately Type of control Single stage heating Dual stage heating Single stage cooling Single stage heating single stage cool ing Dual stage heating single stage...

Страница 67: ...whether the first fan step should also be switched on if the second and third steps are running and whether the second fan should also be switched of if the third step is running 4 4 Symbol overview...

Страница 68: ...Floor lights on 0012 Floor lights off 0013 Standard lamp on 0014 Standard lamp off 0015 Table lamp o 0016 Table lamp off 0017 Light bulb on 0018 Light bulb off 0019 Indirect lights on 0020 Indirect l...

Страница 69: ...open 0044 Door closed 0045 Lock unlocked 0046 Lock locked 0047 Roof window open 0048 Roof window closed 0049 Light dome open 0050 Light dome closed 0081 Display black 0082 Display Green 0083 Display B...

Страница 70: ...ar row 0098 Operating ar row 0099 Skip back 0100 Skip forward 0101 plus 0102 minus 0103 Tool 0104 Switch on 0105 Switch off 0106 On off 0107 Standby 0108 Time 0109 Manual 0110 Automatic 0111 OK 0112 R...

Страница 71: ...0123 Scene 0126 Heater on 0127 Heater off 0128 Underfloor heating 0129 Wall heating 0130 Ceiling heating 0131 Underfloor cooling 0132 Wall cooling 0133 Ceiling cooling 0134 Night cooling 0135 Absent...

Страница 72: ...resent Heating 0262 Present Cooling 0267 Absent Heating 0268 Absent Cooling 0273 Night Heating 0274 Night Cooling 0279 Building pro tection 0280 Building pro tection 0281 Building protec tion 0286 Pre...

Страница 73: ...amp 0162 Outdoor temperature 0163 Indoor temperature 0164 Well 0165 Pond 0166 Wet 0167 Snow fall 0168 Frost 0169 Wind direction 0170 Wind intensit strong 0171 Wind intensity weak 0172 CO2 0173 Cloudy...

Страница 74: ...dspeaker 0199 Volume louder 0200 Volume quieter 0216 Motion detector 0217 Siren 0218 Caution 0219 Key 0220 Intruder in the house 0221 Intruder outside the 0222 Intruder 0223 Siren in the house 0224 Si...

Страница 75: ...73 Basic settings in the ETS CasaConnect KNX Control Center Version 13 09 2021 Technical changes and errors excepted 0246 Garden 0247 Utility room 0248 Storage room 0249 Laundry room...

Страница 76: ...74 Basic settings in the ETS CasaConnect KNX Control Center Version 13 09 2021 Technical changes and errors excepted...

Страница 77: ...75 Basic settings in the Control Center CasaConnect KNX Control Center Version 13 09 2021 Technical changes and errors excepted 5 Basic settings in the Control Center...

Страница 78: ...screen menu System Set screen In the System Set screen menu you can make the following settings KNX settings including naming the functions display in the manual and start menu Create group keys and s...

Страница 79: ...gured the function or name is displayed instead Configure the alarm functions in the ETS first Alarm functions Page 49 Name Displays the name of the alarm object Touch the field and enter the desired...

Страница 80: ...field and select a symbol from the lists Manual menu Shows whether the central function is displayed in the manual menu and in the start menu Touch the field and make your selection The display on th...

Страница 81: ...in order to change the type of output awning windows blinds or shutters Manual direction motors Shows the direction of the motor s movement Touch the field to change the direction of movement Manual m...

Страница 82: ...name using the keyboard that appears The name of the channel can also be entered in the ETS The most recent change in the ETS or the control center applies Block B Page 55 Symbol Displays the selecte...

Страница 83: ...s not yet been acknowledged If Yes is selected the alarm does not disappear until the message has been acknowledged AND the detector returns to Off Touch the field and make your selection Flashing bac...

Страница 84: ...The display on the start page is below the menu items System and Manual menu The display sequence can be set in the menus System Set screen Start page or manual menu 5 2 4 Start page Page 84 5 2 5 Man...

Страница 85: ...ious motors and devices so that they can then be accessed with just one push of a button You can also specify for example that the light should be dimmed and the shutters closed at the same time and s...

Страница 86: ...ted with the web browser open Use the Create bookmark button at the bottom right Favourites and bookmarks are displayed on the left side of the start page You can set different display options here Sy...

Страница 87: ...uch the field to specify the display sequence in the manual menu All entries are shown in a list Hold an entry by the list symbol on the right and move it to the desired position Subject groups Touch...

Страница 88: ...sted If multiple temperature sensors are in stalled select the sensor here the data from which should be displayed on the start page System Set screen Weather data Outdoor temperature Touch the field...

Страница 89: ...the house during the delay before the detectors in the en trance area are live This delay time only applies to external live switching e g via an absence button or the door lock not if you set the al...

Страница 90: ...tuses are described above Intruder alarm Vandalism alarm Attack irrespective of the live status Malfunction Technical alarm 1 2 Recipient for notifications Assign email recipients for the various alar...

Страница 91: ...ult setting Ext live Internal live Enter the text here for the status Internal live Default setting Int live Delay time active Enter the text here for the status Delay time active Default setting Dela...

Страница 92: ...give the appearance that people are in the building A settable delay for the start time makes the simulation more realistic System Set screen Presence simulation Name Shows the name of the presence s...

Страница 93: ...a light is switched on or off Time Event starts at specific time Time and brightness Event starts if a set brightness is undercut in a defined period Event X Event starts as soon as Event X has start...

Страница 94: ...e control center 5 3 1 Settings In the System System settings Settings menu you can make the following set tings Time and date Language Screen Key tone Time zone Location Enter time and date manually...

Страница 95: ...r directory File format Bitmap BMP without RLE compression Jpeg JPG GIF or PNG without transparency For pictures with a page ratio other than 16 10 black bars are added to the top and bottom or left a...

Страница 96: ...d for around 1 min ute the screen brightness is reduced again Switch off on key tone The key tone which is emitted as feedback when a button is touched can be switched off and on again Key tone Shows...

Страница 97: ...tart Reset starts the central control system software again The automatic mode settings are retained After starting the motors and devices for which an automatic reset is set are in automatic mode Tap...

Страница 98: ...evice This is not a remote control option If you want to operate the control center and your building technology when on the go then use the CasaConnect KNX App and set up a secure VPN connection to y...

Страница 99: ...rol center will ask for this new code before displaying the menus Delete code Touch the field and enter the existing code Confirm it and the control center no longer have an access code If you forget...

Страница 100: ...ard supplied 5 minutes after each change memory requirement approx 5 MB When resetting to factory settings the backup file is also overwritten after 5 minutes If you insert the SD card with the backup...

Страница 101: ...on an SD card Information about possible picture information can be found in chapter Set up screen Page 92 The sequence of the catalogue of individual images and of the slide show corresponds to the...

Страница 102: ...ote the information regarding assembly Protect your network with the latest encryption technology and change passwords regularly Connection status Shows the current status disconnected or connected Co...

Страница 103: ...dress Enter your email address Password Enter your password to access the email server provider Sent test email Tap the field to send a test email to your email address Email recipient address Enter u...

Страница 104: ...nect KNX continue Version history Shows the status of the version history of the Control Center Tap the field to display the version history of the CasaConnect KNX Control Center Manual Shows the stat...

Страница 105: ...103 Automatic CasaConnect KNX Control Center Version 13 09 2021 Technical changes and errors excepted 6 Automatic...

Страница 106: ...Set automatic mode System Set automatic mode In the System Set automatic menu you can make the following settings Specify automatic functions of the individual motors and devices Adjust general autom...

Страница 107: ...ntrolled by the system If the full extent of functions is also to be guaranteed if the mains power fails an emer gency generator with corresponding switching from mains to emergency operation should b...

Страница 108: ...hout interruption before the shade is retracted again By selecting the de lay smartly passing clouds are ignored and the shade still responds quickly to the sun Movement delays Displays the extension...

Страница 109: ...er period Night back cooling is then displayed on the start page 7 4 Alarm and error messages Night back cooling Page 137 The window s and ventilator s which are used for the night back cooling as wel...

Страница 110: ...temperature falls below the set frost alarm temperature within the set readiness period after the end of the precipitation The frost alarm ends in the following situation The outdoor temperature rema...

Страница 111: ...ch the movement range of the win dows should be limited Default setting 2 0 C Then set how many hours the outdoor temperature must be above the set outdoor temperature so that the movement limit is ra...

Страница 112: ...ately Automatic reset Shows the time of the automatic reset and the period to reset after manual operation Tap the field to adjust the two settings Set the Time for the daily automatic reset Default s...

Страница 113: ...rity followed by timed closing extend night closing extend and indoor temperature lock keep retracted The Automatic shading according to light intensity is performed only when the direction and height...

Страница 114: ...is not considered Sun height Shows the area height above the horizon where the sun must be so that the shade is opened Touch the field to set the angle using a slider The setting is only active if sha...

Страница 115: ...ect OFF if the shading should depend on the indoor temperature default setting Change to ON to set the desired temperature Default setting 25 0 C By using the indoor temperature block the sun s energy...

Страница 116: ...nec essary Default setting No The rain automatic is used to clean the curtains by rain and or to protect the window panes from wetness by moving the shade to a selectable position The rain automatic c...

Страница 117: ...alarm rain alarm and manual movement commands if the outside temperature block is active Note that the running rails of the shades or other mechanical parts may still be frozen even if the outdoor tem...

Страница 118: ...on of the shade is initially blocked You can re move the manual block by hand however To do this select the corresponding shade in the Manual menu and hold down the button with the frost alarm icon fo...

Страница 119: ...retracting the shades The rain alarm can only be activated if the rain automatic is deactivated Automatic reset Shows which automatic resets apply to these shades Touch the field in order to acti vat...

Страница 120: ...ion a closing time for electric windows or sliding roofs has to be included in the calculation Mois ture sensitive objects should therefore not be placed in areas where thy could be dam aged by enteri...

Страница 121: ...temperature default Change to ON to set the desired temperature Default setting 21 0 C The window is opened as soon as the temperature lies above the pre set value How ever it is only closed again whe...

Страница 122: ...ck is however only deactivated again when the supply air temperature sinks more than 3 0 C below the room temperature hysteresis Number of steps Shows the number of opening steps for the window Touch...

Страница 123: ...tion night back cooling Shows the actuation position in percent during night back cooling Touch the field to set the position using a slider 0 closed 100 fully open The setting will only be activated...

Страница 124: ...re than 2 0 C over the pre set value hysteresis The effect of the block is that the window remains in the current position The outside temperature block can be used for example if the window should no...

Страница 125: ...window can still be opened slightly despite a wind alarm Wind ventilation Direction Shows the wind direction for when wind ventilation opens The setting is only active if wind ventilation has been swi...

Страница 126: ...n alarm When gap opening the window can still be opened slightly despite a rain alarm Rain alarm Position Shows the position to which the window opens for gap ventilation The setting is only active if...

Страница 127: ...3 9 Specify automatic reset Page 109 Manual switching Shows whether a position message is used by the motor to switch from automatic to manual i e whether automatic mode is switched off by pressing a...

Страница 128: ...h is evaluated for the controls Touch the field and select a sensor Default setting No sensor If no sensor is selected the indoor temperature and humidity are not taken into ac count for the controls...

Страница 129: ...N in order to set the VOC concentration range Default setting Open above 1000 ppm close below 700 ppm Ventilation intensity Shows the minimum and maximum ventilation intensity The ventilation intensit...

Страница 130: ...erature has been set Default setting 20 0 C NBC Intensity night back cooling For exhaust air units shows the speed during night back cooling Touch the field to ad just the strength using a slider The...

Страница 131: ...n of the outside air from which the ventilation is off The setting is only active if an outdoor sensor with VOC sensor is selected Tap the field to adjust the VOC value Select OFF if the window should...

Страница 132: ...e or more times in the list If you want to change the periods touch the tool icon 6 3 4 Set time switch event Page 107 Automatic reset Shows which automatic resets apply to this heating Touch the fiel...

Страница 133: ...ight is switched on at twilight night Touch the field and switch the function on or off If the twilight setting is active the light is only turned on at twilight in the time periods selected above The...

Страница 134: ...b sequence and the end of the bright ness and the colour temperature The control center calculate the linear progress of the values between the start and end value The aim of the HCL controls is to im...

Страница 135: ...133 Tables maintenance CasaConnect KNX Control Center Version 13 09 2021 Technical changes and errors excepted 7 Tables maintenance...

Страница 136: ...sing a wet cloth or a microfibre cloth Use the cleaning mode for this This function locks the touch display for 60 seconds and thus prevents functions from being triggered or adjusted uninten tionally...

Страница 137: ...l regulations Do not dispose of it with the household waste 7 4 Alarm and error messages Messages about an active alarm are displayed by the corresponding red icons on the manual page of the relevant...

Страница 138: ...splayed during commissioning or following a restart of the control center As soon as the weather station receives a time signal this display disappears If nothing is re ceived please set the clock man...

Страница 139: ...Page 109 Not all the weather data is received correctly If a weather sensor is not connected via the KNX bus or if the weather sensor is defec tive the wind rain and frost alarms are activated as a p...

Страница 140: ...No connection to KNX bus shows a malfunction or defect in the KNX interface No communication with the bus takes place Check the KNX connection Alarm The icon at the top right shows that an alarm has...

Страница 141: ...internal and external live switching an intruder alarm is triggered as intruder alarm Indoor skin for external live switching an intruder alarm is trig gered as vandalism alarm a vandalism alarm is t...

Страница 142: ...losing Rain automatic Time closing period Actuation position timer Outdoor temperature C Behaviour Timed opening Frost alarm Wind sensor Wind alarm in m s time overrun Rain alarm Automatic reset Manua...

Страница 143: ...triction to position Outdoor temperature C Time closing period Wind sensor Wind ventilation Wind ventilation direction Wind ventilation position Wind alarm in m s time overrun Rain alarm Gap ventilati...

Страница 144: ...ture C Timed closing Automatic reset Manual switching Ventilation lock through air conditioning min Output Name Timed closing mode Automatic reset Manual switching Output Name Time switch period Twili...

Страница 145: ...nsion delay shades min Retraction delay shades min ventilation lock after cooling min Night back cooling Temper ature C for longer than min Frost alarm Outdoor tem perature C readiness h Window moveme...

Страница 146: ...CasaConnect KNX Control Center Version 13 09 2021 Technical changes and errors excepted Events of the time switch 15 16 Name Time 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26...

Страница 147: ...145 Tables maintenance CasaConnect KNX Control Center Version 13 09 2021 Technical changes and errors excepted 30 31 32 Name Time...

Страница 148: ...bH Control and Automation Engineering Sohlengrund 16 75395 Ostelsheim Phone 49 0 70 33 30 945 0 info elsner elektronik de Germany Fax 49 0 70 33 30 945 20 www elsner elektronik de Technical support 49...