manualshive.com logo in svg
background image

Motor Control Unit MSG1 compact

1

Motor Control Unit MSG1 compact

 • Version: 02.06.2020 • Technical changes and errors excepted. • Elsner Elektronik GmbH • Sohlengrund 16 • 75395 Ostelsheim • Germany • www.elsner-elektronik.de • 

Technical Service: +49 (0) 7033 / 30945-250

MSG1 compact

Motor Control Unit

1.

Description

The 

Motor Control Unit MSG1 compact

 controls 230 V drives, e.g. shading or

window motors. The relay at the motor output is a low-wear zero-crossing switch. 

The device is equipped with inputs for central control and for a manual switch. The
central input can be set to dead man's switch or lock and is suitable e. g. for timers,
push buttons or control systems. An unlocked twin push button is connected to the
switch input for manual operation. This input is equipped with time-automated but-
tons (step operation/lock).

Functions:

Output  for  a 

230 V AC drive

 (Up/Down)

Use as a 

central, group and single controller

Central input

 up/down 12...28 V DC (with priority) e.g. for switches, controls 

Setting the central control unit to "Dead man" or "Lock". As long as voltage is 
present at the central input, the manual operation is blocked

Manual operation

 by connecting an unlocked double push-button to the 

Input "Local".
Push-button timer automatic: Inching mode (press for less than 1 second): 
Drive inches, for example for positioning slats on shutters.
Drive mode (press for longer than 1 second): Drive travels automatically to 
the final position 

Lockout inputs

 for Local Up, Local Down, Central Down

Direction change pause 1 second 

1.1. Deliverables

Motor control unit

1.2. Technical specification

The product conforms with the provisions of EU directives.

2.

Installation and start-up

2.1. Installation notes

Installation, testing, operational start-up and troubleshooting should 
only be performed by an electrician.

DANGER!
Risk to life from live voltage (mains voltage)! 

There are unprotected live components within the device.

VDE regulations and national regulations are to be followed.

Ensure that all lines to be assembled are free of voltage and take
precautions against accidental switching on.

Do not use the device if it is damaged. 

Take the device or system out of service and secure it against
unintentional use, if it can be assumed, that risk-free operation is no
longer guaranteed.

The device is only to be used for the intended purpose described in this manual. Any
improper modification or failure to follow the operating instructions voids any and
all warranty and guarantee claims.

After unpacking the device, check it immediately for possible mechanical damage.
If it has been damaged in transport, inform the supplier immediately.

The device may only be used as a fixed-site installation; that means only when as-
sembled and after conclusion of all installation and operational start-up tasks and
only in the surroundings designated for it.

Elsner Elektronik is not liable for any changes in norms and standards which may
occur after publication of these operating instructions.

2.2. Safety notice for automatic functions

WARNING!
Risk of injury from automatically moving components!

Parts of the system can be started by the automatic controls
and be a danger to persons.

No persons may remain in the travelling range of parts
driven by an electric motor.

•  Adhere to the relevant building regulations.

Ensure that the return path/access to the building is not blocked
if spending time outside the building (danger of being locked out).

Correctly decommission the system for maintenance and 
cleaning work.

If there is a power outage, the system does not work. Therefore, shadings should be
moved to a save position if there are anticipated weather conditions, for example, if
this has not already been done by the automatic function (product protection). 

If the power supply is removed, the connected drive switches off. When the power
is restored, the consumer remains switched off until a new movement command is
received by the actuator.

2.3. Design of the MSG1 compact / Connection

Connection example 1

Assembly

Installation

Protection category

IP 20

Dimensions

Ø approx. 53 mm, depth approx. 29 mm

Weight

approx. 80 g

Ambient temperature

Operation -20…+45°C, storage -55…+90°C.
Avoid condensation

Operating voltage

230 V AC

Power consumption

Operation maximum 2.0 W

Maximum load

Each terminal contact may be loaded with a 
maximum of 10 A.

Output

1× 230V drive (Up/Down/PE/N)

Inputs (SELV)

1× Central command (Up/Down/+/-)
1× Manual command via present button (Up/
Down/+/-)
1× Lock Local Down
1× Lock Local Up
1× Lock Central Down
Voltage for inputs 12...28 V DC
Maximum line length 100 m

Lock mode

Command at least 1 s
Travel time 4 min

Direction change pause

1 s

Technical specifications and 
installation instructions

Article number 70454

Fig. 1
1 Lock inputs: Local down/up, Cen-

tral down 

2 Central input (up/down),

Voltage - (12...28 V DC) for inputs

3 V (12...28 V DC) for in-

puts,
Push-button input local (up/
down)

4 Mode LED
5 Actuator output (down/L/N/up),

Operating voltage (L/N)

1

3

4

5

2

N

PE

L

PE N

Control/

Fig. 2

The internal voltage (9 ... 12
V DC) is used to supply the
inputs. When using several
motor control units which
receive the same central
command, the "-" connec-
tions must be bridged for
potential equalisation. 

In this way, a 

MSG1 com-

pact

 can supply up to 100

additional motor control
units with power for central
control.

Each terminal contact may
be loaded with a maximum
of 10 A.

   Central command

Mains

Central

further MSGS

Button local

230 V AC

EN

Отзывы: