12
Parameter setting
Radio actuator KNX RF MSG-DST
Version: 27.06.2018 • Technical changes and errors excepted.
4.
Parameter setting
The default settings of the parameter are labelled by an underscore.
4.1. General settings
First, set the general parameters for the bus communication (transmission delay). Ad-
ditionally, you can indicate if for the programming of scenes all, or only the changed
settings are applied to the bus.
When labelling objects, you can enter an additional label (abbreviation) for the objects
of the device, e.g. ‘LR’ for ‘living room’, to make the room installation more transpa-
rent.
4.2. Operating Mode
Choose the operating mode of the drive.
4.2.1. Drive - Shutter, Blind, Awning, Window
Set the general parameters for the drive.
Driving direction:
Up/down, on/off or open/close can be exchanged.
Runtime:
The runtime between the end positions is the basis for moving into intermediate posi-
tions (e.g. for movement range limits and scenes). You can enter the runtime numeri-
cally (in seconds) or have the runtime determined automatically. The actuator specifies
Send delay of threshold values after
voltage returns
5 s … 2 h
Send delay of switching and status outputs
after voltage returns
5 s … 2 h
For the use of scenes:
Application when programming
all parameters • only changed parameters
Object labelling
[Free text max. 20 characters]
Operating mode
• do not use
• shutter
• blind
• awning
• window
Exchange UP/DOWN
(shutter, blinds)
Exchange ON/OFF
(awning)
Exchange OPEN/CLOSE
(window)
no • yes