background image

10

Installation and Commissioning

Power Supply Systems KNX PS640+ and KNX PS640+USB

Version: 19.08.2020 • Technical changes and errors excepted.

3.4.3. External Overvoltage

3.4.4. Internal Overvoltage

3.4.5. Short Circuit

3.4.6. Excess Temperature

3.5. Operating data

External Overvoltage
was detected     
0 times.
< = Back

The  number  of  external  overvoltage  incidents  is
displayed.

With key

   

you return to the previous menu level.

Internal Overvoltage
was detected     
0 times.
< = Back

The  number  of  internal  overvoltage  incidents  is
displayed.

With key

   

you return to the previous menu level.

A short at the bus was 
detected
 0 times.
< = Back

The number of short circuit incidents at the bus is
displayed.

With key

   

you return to the previous menu level.

Excess Temperature  on 
the board
was detected
 0 times!

The  number  of  excess  temperature  incidents  on
the circuit board of the device is displayed.

With key

   

you return to the previous menu level.

elsner elektronik
KNX Power Supply
Normal Operation
Diagnostics >

In starting position, press key   once.

Line Reset 

>

Data Memory

>

Operating Data >  ™
Language

>

Move the cursor (flashing rectangle at right edge)
to  the  „Operating  Data“  menu  with  the  keys

 

and 

 

and confirm with key  .

Содержание 70141

Страница 1: ...KNX PS640 and KNX PS640 USB Power Supply Systems EN Installation and Adjustment KNX PS640 Item number 70141 KNX PS640 USB Item number 70144 ...

Страница 2: ......

Страница 3: ...ection examples for a KNX system 6 2 3 Power Supply 7 2 3 1 Housing example with central operating unit 7 2 4 Starting Position 8 2 5 Key functions in display menu 8 2 6 Line reset 8 2 7 Data memory 9 2 7 1 Operating hours 9 2 7 2 Overload 9 2 7 3 External Overvoltage 10 2 7 4 Internal Overvoltage 10 2 7 5 Short Circuit 10 2 7 6 Excess Temperature 10 2 8 Operating data 10 2 9 Language 11 3 Disposa...

Страница 4: ...leshooting of the device must only be carried out by a competent electrician Safety advice Safety advice for working on electrical connections components etc DANGER indicates an immediately hazardous situation which will lead to death or severe injuries if it is not avoided WARNING indicates a potentially hazardous situation which may lead to death or severe injuries if it is not avoided CAUTION i...

Страница 5: ...not reduced output current max 150 mA Reset of a line directly on the device Record of operating hours overload external overvoltage internal overvoltage short circuit and excess temperature Display of operating data bus voltage bus current and temperature of the device The display may be shown in German English Spanish or Dutch Bus connection for data transfer e g malfunction messages operating d...

Страница 6: ...teed The device is only to be used for the intended purpose described in this manual Any improper modification or failure to follow the operating instructions voids any and all warranty and guarantee claims After unpacking the device check it immediately for possible mechanical damage If it has been damaged in transport inform the supplier immediately The device may only be used as a fixed site in...

Страница 7: ...the device will enter an initialisation phase lasting 5 seconds During this phase no information can be received via the bus 2 2 1 Housing 2 Fig 1 1 Bus voltage power OUT KNX terminal 2 Programming LED and programming bushbutton 3 Bus data KNX terminal connection for line or main line or sector 4 Input operating voltage 230 V AC L N PE 5 USB interface only KNX PS640 USB 6 Output direct current vol...

Страница 8: ...ystems KNX PS640 and KNX PS640 USB Version 19 08 2020 Technical changes and errors excepted 2 2 2 Scheme 2 2 3 Connection examples for a KNX system Auxiliary supply 24 V DC max 150 mA Fig 2 0 45 C Fig 3a without line coupler Fig 3b with line coupler ...

Страница 9: ...tallation and Commissioning Power Supply Systems KNX PS640 and KNX PS640 USB Version 19 08 2020 Technical changes and errors excepted 2 3 Power Supply 2 3 1 Housing example with central operating unit Fig 4 ...

Страница 10: ...nds if during this period no key is pressed 3 2 Key functions in display menu 3 3 Line reset Confirms the selection moves to the next step One step back Changes a setting selects a setting or changes a value The cursor the blinking rectangle indicates the selected menu item ok Confirms the settings and returns to the device main menu elsner elektronik KNX Power Supply Normal Operation Diagnostics ...

Страница 11: ...sual During the reset state which lasts 30 seconds the basic setting displays Reset active XX sec countdown elsner elektronik KNX Power Supply Normal Operation Diagnostics In starting position press key once Line Reset Data Memory Operating Data Language Move the cursor flashing rectangle at right edge to the Data memory menu with the keys and and confirm with key Hours ofOperation Overload Ext Ov...

Страница 12: ...rvoltage incidents is displayed With key you return to the previous menu level A short at the bus was detected 0 times Back The number of short circuit incidents at the bus is displayed With key you return to the previous menu level Excess Temperature on the board was detected 0 times The number of excess temperature incidents on the circuit board of the device is displayed With key you return to ...

Страница 13: ...nce with the legal reg ulations Do not dispose of it with the household waste Bus Voltage 29 4 V Bus Current 320 mA Temperature 42 1 C elsner elektronik KNX Power Supply Normal Operation Diagnostics In starting position press key once Line Reset Data Memory Operating Data Language Move the cursor flashing rectangle at right edge to the Language menu with the keys and and confirm with the key Sprac...

Страница 14: ...et 1 30 seconds active 0 inactive Input 1 003 C R W 4 Reset status of the line 1 active 0 inactive Output 1 002 C R T 5 Overload 0 normal 1 overload Output 1 002 C R T 6 external overvoltage 0 normal 1 overvoltage Output 1 002 C R T 7 internal overvoltage 0 normal 1 overvoltage Output 1 002 C R T 8 Short circuit 0 normal 1 short circuit Output 1 002 C R T 9 Overtemperature 0 normal 1 overtemperatu...

Страница 15: ...Increment Input 1 017 C R W 23 Threshold value Decrement Input 1 017 C R W 24 Threshold value Switching output Output 1 002 C R T 25 Threshold value Switching output block Input 1 003 C R W 26 Software version readable 217 001 C R Transmission behaviour object bus voltage do not send send cyclically send in case of change send in case of change and cyclically Sending cycle only if sending cyclical...

Страница 16: ...ng 5 sec 10 sec 30 sec 1 min 2 h Object overload do not send send in case of change send in case of change to 1 send in case of change to 0 send in case of change and cyclically send in case of change to 1 and cycli cally send in case of change to 0 and cycli cally Sending cycle only if sending cyclically 5 sec 10 sec 30 sec 1 min 2 h Object external overvoltage The setting options are similar to ...

Страница 17: ... underrun Error log Object 1 bit malfunction collection This object results in a disjunction of the 1 bit malfunction objects do not send send in case of change send in case of change to 1 send in case of change to 0 send in case of change and cyclically send in case of change to 1 and cyclically send in case of change to 0 and cyclically Sending cycle only if sending cyclically 5 sec 10 sec 30 se...

Страница 18: ... Use threshold value No Yes Threshold value is set by Parameter Threshold value in mA 0 640 Hysteresis of the threshold value in 0 50 Threshold value is set by Communication object The value communicated last shall be main tained not after restoration of voltage after restoration of voltage and programming Do not use for first commissioning Start threshold value in mA valid until 1 communication o...

Страница 19: ...lically send in case of change to 1 and cycli cally send in case of change to 0 and cycli cally Send switching output in a cycle of only if sending cyclically 5 sec 10 sec 30 sec 1 min 2 h Use block of the switching output No Yes Use block of the switching output Yes Evaluation of the blocking object if value 1 block if value 0 release if value 0 block if value 1 release Value of the blocking obje...

Страница 20: ...s KNX PS640 and KNX PS640 USB Version 19 08 2020 Technical changes and errors excepted in case of change to 1 and cyclically if switching output 1 send 1 no selection in case of change to 0 and cyclically if switching output 0 send 0 no selection ...

Страница 21: ......

Страница 22: ...mbH Control and Automation Engineering Sohlengrund 16 75395 Ostelsheim Phone 49 0 70 33 30 945 0 info elsner elektronik de Germany Fax 49 0 70 33 30 945 20 www elsner elektronik de Technical support 49 0 70 33 30 945 250 ...

Отзывы: