40
Automatic settings
Control System WS1 Color / WS1000 Color
• Version: 14.12.2016 • Technical changes and errors excepted.
Press the button to enable or disable the switchover to automatic mode at a set point
in time, or following a manual intervention.
The general Automatic Reset occurs daily at the same time.
Switching on: To set the blind respectively the roller shutter to Automatic at a set point
in time, select
Yes
(this is the default setting).
Switching off: To switch off the blind’s/shutter’s Reset function, select
No
.
Alternatively, the automatic function can be reactivated at a set time following a man-
ual intervention.
Switching on: To perform an Automatic Reset after a manual intervention, select
Yes
.
Switching off: To switch off the blinds’s/ shutter’s Reset function, select
No
(this is the
default setting).
Confirm your setting with the
OK
button.
Automatic Reset time and/or period can be set.
System > Automatic Settings > General Settings > Automatic Reset
3.3. Define automatic reset
3.1.6. Automatic window settings
For connected windows, sliding roofs, step windows or window groups, the following
automatic settings can be changed:
•
Indoor sensor to be used for the window
•
Indoor temperature
•
Air humidity
•
Supply air temperature
•
Night-time re-cooling (together with indoor temperature and movement
position for night-time re-cooling)
•
Movement position (only for sliding windows)
•
Number of steps (only for step windows)
•
Timed ventilation
•
Outdoor temperature
•
Timed closure
•
Frost alarm
•
Wind alarm
•
Rain alarm
•
Gap ventilation
•
Gap position
•
Enable/Disable automatic reset
Alarm Functions
Alarm functions are used for windows in manual and in automatic mode.
Automatic Reset