Страница 3: ...7 Final Check 8 3 MAINTENANCE 3 1 Cleaning 9 3 2 Bearings 9 3 2 1 Lubrication of Bearings 9 3 2 2 Bearing Replacement 11 3 3 Sealing Component 11 4 FAULTS REASONS AND SOLVINGS 4 1 Tables of Troublesh...
Страница 4: ...he conditions specified in this instruction catalog and name plate or not having the necessary protection schemes in accordance with TS 10316 EN 60204 1 are excluded from the warranty The structural c...
Страница 5: ...is to be stored for a long time it must be kept a place which is clean free of moisture and vibration 1 4 SAFETY Vibrating motors are connected to the power supply network and are rotated by magnetic...
Страница 6: ...lation resistance measuring device megaohmmeter and the resistance is read at the end of one minute Insulation resistance value measured at 25 C 10 M in a new vibration motor and 1 M in a vibration mo...
Страница 7: ...tal of four eccentric hammers are available in a vibration motor with two fixed and two adjustable Our vibration motors are shipped with the eccentric hammers set to step 3 85 The vibration force is i...
Страница 8: ...allel If the adjustment is made in a different direction the position of the hammers on both sides is not the same parallel the vibration motor shaft the vibration motor mounting bolts and or the chas...
Страница 9: ...than 1 05 times the rated current of the vibration motor Otherwise the vibration motor is not covered by the warranty Overload protection will only be possible by sensing excessive heat caused by over...
Страница 10: ...5 50Hz 2 2 If the vibration motors are not used for a long time the insulation resistance values must be sufficient 3 All mechanical and electrical connections must be tight 4 The moving and energize...
Страница 11: ...o use the type of grease indicated on the vibration motor plate In the case of initial lubrication no grease should be expected from the discharge duct After several lubrication dirty grease will appe...
Страница 12: ...12 4 327 2 2 kW 2 250 15 VEMS 112 4 413 2 4 kW 2 100 26 VEMS 112 4 456 3 2 kW VEMS 112 6 145 1 5 kW 2 900 15 VEMS 112 6 202 2 kW VEMS 132 2 530 4 kW 900 22 VEMS 132 4 551 3 5 kW 2 000 34 VEMS 132 6 41...
Страница 13: ...ls and the bearing inner ring made of the shaft diameter When attaching the vibration motor bearing covers suitable tools should be used with the cover diameter To replace the bearings the rotor and s...
Страница 14: ...relay or thermistor phase protection relay has deactivated the vibration motor Check the thermic relay thermistor and thermistor relay The ground mounting bolts are loose Tighten the bolts The vibrati...
Страница 15: ...ck the current The vibration motor is warm when it is running without load Mains voltage is high Measure the mains voltage and the no load current The vibration motor stops for a certain period of tim...
Страница 16: ...and axial forces if any Lubrication problem Take care to lubricate The eccentric hammer adjustment of the vibration motor is distorted Adjust the eccentric hammers of the vibration motor so that they...
Страница 17: ...mber 4 Ingress Progress Class 5 Operating Environment Temperature C 6 Input Power kW 7 Centrifugal Force kgf 8 Rated Speed 1 dak 9 Rated Current A 10 Power Factor Cos 11 Frequency Hz 12 Voltage V 13 W...
Страница 18: ...16 6 COMPONENT OF VIBRATOR______________________________________________________ 6 1 PART MAPING WITH SECTION VIEW Figure 6 Part mapping of vibration motor...
Страница 19: ...MER 12 SETTING HAMMER 13 HAMMER CLAMPING BOLT 14 SHAFT RING FOR HAMMER 15 LUBRICATION FITTING 16 O RING SEALING COMPONENT 17 SAFETY COVER 18 TERMINAL BOARD 19 TERMINAL BOX COVER 20 CABLE GLAND Table 4...
Страница 20: ...hines TS EN 60034 18 1 Insulation and thermal classification TS EN 50347 Identification of Induction Motor Table 5 List of related standarts 7 OTHER INFORMATION 7 2 INDEX OF FIGURE AND TABLE FIGURE NA...