background image

1- Introduction

The receiver 

 is a superheterodyne receiver operating at the 

frequency 433,92 MHz in AM/ASK modulation.It is composed by a main board in which there 
are the power supply  output connectors and by a RF card.
Are available 3 open-drain outputs: DATA0 and DATA1, with Wiegand 26 or 30 bit format and 
a CLOCK 
It’s possible to make a backup and a restore of the memory data to an external memory. 
The appliance is housed in an indoor enclosure
The product fully complies with European Directive 72/23/CEE , 89/336/CEE  and 
Regulation 

2 - Compatibel transmitters

!

024A 

Type  S2TR 2641 E2-E4:

 2/4 button transmitters

!

Mini 

Type  SETR 2641 AM2:

2 button mini transmitter

!

Mural  

Type  SETR 2641 TM:

Wall transmitter

!

Digikey

Type  SEDK 2641A4:

Keypad transmitter

3 - Technical specifications

Wiegand 26 or 30 bit

Outputs type

DATA0, DATA1, CLOCK

4 - Caracteristiques principales

Wiegand CDVI ( F0103000069)

 EN 60065.

Receiver type

Superheterodyne

Demodulation

AM

Carrier frequency

433,92 MHz

Local oscillator frequency

6,6128 MHz

Intermediate frequency

10,7 MHz

Sensitivity

-115 dBm

Output impedance

50 Ohm

Power  supply

12/24 Vac/dc

Current consumption :

25 mA

Outputs

Max code number

800

Operating temperature

-20 - +70°C

Ovarall dimensions (fig. 1)

105 x 45 x 28 mm

Weight

65 g

 - 800 transmitter codes memory.
 - Wireless transmitter memorisation
 - Backup and restore of memory data to and external memory 
 - Déplacement du contenu de la mémoire d'et vers une mémoire de copie externe;
 - Full memory erasure.
 - Output signal DATA0, DATA1, CLOCK with 10KOhm pull-up resistor   
 - Output signal DATA0 and DATA1 which fullfill to 26 or 30 bit Wiegand standard (see. 

Par. 16 - 17) 

 

RICEVITORE SEL2641R433-IP

CDVI WIEGAND RECEIVER F0103000069

1) Appuyer pour 2 
sec. PR

2

PR

LR

LV

2) La led LR 
s'allume

4) Appuyer la 
clef du TX 

LR et LV clignotent 2 
2 fois

Fig. 1

105

28

45

Overall dimensions

 - The CLOCK signal is the logic OR of DATA0 and DATA1 

5 -Receiver details  ( Fig. 2)

LR:

Led Red

LV:

Led Green

PR:

Push button red

PV:

Push button green

CT 

Backup Memory connector 

6 -Connections ( Fig. 2)

Power supply :

Terminals 1 and  2  : 12 Vac/dc
Terminals 1 and  3  : 24 Vac/dc

Antenna :

Terminal  9    

: GND antenna (  RG58)

Terminal 10    : Antenna.

Clock:

Terminal 6 

: CLOCK

Wiegand:

Terminal 7 

: DATA_0, 

Terminal 8 

: DATA_1

Fig. 2

Connection

Fig. 3

7 - Backup memory plug-in

To plug-in the backup memory remove the transparent cover and plug-in the memory into 
the corresponding 4-ways female connector (CT), making attention to the right polarization : 
the round shape has to be put inward facing the radio card. (Fig. 3)

Fig. 4

10

9

8

7

6

5

4

3

2

1

+

-

+

12V

0V

AC/DC

24V

PR

LR

PV

LV

CT

N.C. NC

C

LO

C

K

D

A

TA

_0

D

A

TA

_1

LR

3) Relâcher le 
bouton

1) Appuyer 
pour 2 sec. PR

2

PR

LR

LV

2) Laled LR 
s'allume

4) Appuyer la 
clef du TX

LR et LV clignotent 2  
fois

Fig. 5

LR

3) Relâcher 
le bouton

4) Appuyer 1,2 ou 
3 fois pour 
mémoriser sur les  
cellules 1, 2 ou 3 
de memoire

Memory plug-in

8 - Receiver initialization

The receiver enables the access, sending out the corresponding Wiegand message, only 
to the transmitters with the FACILITY CODES memorized.
The init operation has to be performed during the product installation.
In this way it’s possible to memorise up to 2 FACILITY CODES and to enable up to 4 
transmitter keys. The internal receiver memory has 4 locations which keep this 
information.

Procedure

1) Memorisation of the first transmitter key ( Fig.4)
Keep the button PR pressed down until the led LR turns on and then release it.
Press the first key of the transmitter: in this vay the key and the FACILITY CODE of the transmitter 
are stored into the first memory location.

2) Memorisation of the second transmitter key ( Fig.5)
Keep the button PR pressed down until the led LR turns on and then release it.
Press the button PR again once and the led PR will flash once by confirming that the location N° 
1 is going to be memorised : at that point press the second key of the transmitter.

3) Memorisation of the third transmitter key ( Fig.5)
Keep the button PR pressed down until the led LR turns on and then release it.
Press the button PR again twice and the led PR will flash twice by confirming that the location N° 
2 is going to be memorised : at that point press the third key of the transmitter.

4) Memorisation of the fourth transmitter key ( Fig.5)
Keep the button PR pressed down until the led LR turns on and then release it.
Press the button PR again three times and the led PR will flash three times by  confirming that the 
location N° 2 is going to be memorised : at that point press the third key of the transmitter.

Finally the led RED and GREEN will flash twice simultanuosly.

NOTE : the init procedure set the enabled FACILITY CODE and transmitter KEYS but doesn’t 
store the serial number.
This is done in self-learning for each transmitter. Only at the end of the self-learning procedure 
the wiegand frame is sent out by the receiver.

9 - Replacement of a location already occupied

ATTENTION : If the memorisation is done on a location already occupied, the cell is replaced 
with the new data. 

Отзывы: