Safety Instructions 

 
Intended Use 

LIBERO CE/CH/CL data loggers are 

exclusively for commercial use (“business to business”)

 in industrial 

environments, representing monitoring solutions for temperature and humidity measurement with 
internal and external sensors. LIBERO CE/CH/CL data loggers are not intended for use with children or in 
vicinity of children. 
If the device is used in a manner not specified by the manufacturer protection provided by the device 
may be impaired! 

 
Battery 

Material safety data sheets according to provisions of directive 91/155/EEC and shipping information 
are available from ELPRO-BUCHS AG. Do not subject the batteries to mechanical stress nor dismantle 
them. The leaking battery fluid is highly corrosive and can generate severe heat when it comes into 
contact with moister or it can ignite fire. 
 

Environmental Conditions 

Temperature 

Temperatures exceeding 70°C can damage the battery. For the operation 
range see specifications on www.elpro.com. 

Water 

Device meets requirements of protection class IP54. Only for use in the 
specified IP protection class, penetrating water or moister can damage the 
device. The degrees of protection apply to any position and orientation of 
the device, regardless of the mounting arrangement.    

Humidity 

Mechanical Force 

Operation range 0 … 100

 %RH 

Violent shocks and impacts can damage the battery (short circuit). 

IR and Steam 

Infrared radiation (heat) and superheated steam can damage the surface 
coating of the casing. 

Microwave 

There is a risk of battery explosion if the device is exposed to microwave 
radiation. 

UV Radiation 

Pollution 

Exposure to UV radiation diminishes the stability of the casing. 

Pollution of the device can lead to malfunctions. Maximum permissible 
pollution: Grade 2 

 

Cleaning 

For cleaning purpose use a slightly wetted cloth. Do not use thinner, fuel, alcohol or agressive cleaning 
detergents, they can damage the casing. 
 

Bluetooth 

The product operates in 2.40-2.48 GHz band with a maximum radiated output power of +3.7 dBm. 

 
Distance to the body 

The device should be installed and operated with a minimum distance of 20 cm between the device and 
your body. 
 

Содержание 802279

Страница 1: ...PM WU 1000475V01E DOC_Operation Manual LIBERO Cx BLE docx Page 1 34 LIBERO CE CL CH Operation Manual...

Страница 2: ...d 11 4 3 2 Alarming ON OFF function configured 11 4 4 Technical Specifications 12 5 Accessories 13 5 1 External Pt100 Probes for LIBERO CE 13 5 1 1 Cryogenic shipments and storage 13 5 1 2 Dry ice shi...

Страница 3: ...range see specifications on www elpro com Water Device meets requirements of protection class IP54 Only for use in the specified IP protection class penetrating water or moister can damage the device...

Страница 4: ...1000475V01E DOC_Operation Manual LIBERO Cx BLE docx Page 4 34 2 Quick Start Guides LIBERO CE LIBERO CL LIBERO CH...

Страница 5: ...le superior temperature data transfer to the data logger Up to 75 500 temperature values can be stored on the data logger Release products with confidence based on the OK or ALARM status on the displa...

Страница 6: ...dity thresholds MKT and duration as alarm criteria LIBERO CH allows you to create temperature humidity profiles for individual products In addition you have the option to switch the alarming function...

Страница 7: ...n if required When plugged into the USB port of a PC the device is automatically recognized by the liberoCONFIG software and set to ConF mode without the need to press any keys The logger can be start...

Страница 8: ...ode Run indicator top left on the display and the status Alarming ON top center section of the display which indicates that the measured values are evaluated according to set alarm criteria LIBERO CH...

Страница 9: ...oes not forget to read out the device and it disappears after the PDF report has been created by plugging the device into the USB port of a computer After the device has been read out Stop appears on...

Страница 10: ...ate is indicated in the display by the message EoL End of Life the logger can no longer be used Reduction of battery runtime Depending on the Bluetooth mode selected there is a reduction in the servic...

Страница 11: ...The following figure shows the sequence of modes if Alarming ON OFF function has not been configured see chapter 6 section Alarm Conditions 4 3 2 Alarming ON OFF function configured The following figu...

Страница 12: ...s LIBERO CE https shop elpro com daten img Documents TechSpecs LIBERO TS_LIBERO_CE_BLE_EN_web pdf LIBERO CL https shop elpro com daten img Documents TechSpecs LIBERO TS_LIBERO_CL_BLE_EN_web pdf LIBERO...

Страница 13: ...genic shipments and storage Dry ice shipments and storage Freezer 25 C 15 C typ fridge 2 C 8 C ambient 15 C 25 C shipments and storage 5 1 1 Cryogenic shipments and storage For cryogenic applications...

Страница 14: ...ual LIBERO Cx BLE docx Page 14 34 ELPRO offers two Pt100 standard probes for cryogenic applications with M8 connector in different lengths PRO_PT100_ST300D3_M8_CRYO part number 802287 PRO_PT100_ST350D...

Страница 15: ...iner using the optionally available stainless steel bracket and the sensor leads into the tank ELPRO offers an easy turnkey service for mounting the assembly and calibration For this application ELPRO...

Страница 16: ...e ambient shipments and storage For temperature monitoring of freezers refrigerators or rooms ELPRO offers two waterproof silicon Pt100 probes with different cable lengths as standard articles PRO_PT1...

Страница 17: ...on of sensor cables An extension cable with two M8 connectors at a length of 1m is also available to attach the PDF data logger and the probe ATTENTION Total cable length including sensor and cable ta...

Страница 18: ...n M8 connector to a Pt100 temperature sensor in order to use any 4 wire Pt100 probe in combination with LIBERO CE CTR_M8_SER part number 802289 5 4 Stainless steel bracket ELPRO offers an optional sta...

Страница 19: ...O Cx is done with liberoCONFIG With SmartStart Pack Go a profile can be assigned to a larger number of LIBEROs quickly and safely SmartStart Pack Go exe files can be used on any PC without installatio...

Страница 20: ...ggers are for multiple use NOTE When memory capacity of the logger is reached newly measured values continuously overwrite the oldest stored values For temperature or time delayed alarm activation the...

Страница 21: ...values between the last pressing of the Alarming ON button and the last pressing of the Alarming OFF button on the device are considered in the assessment If the Alarming ON button was pressed last i...

Страница 22: ...button Stop by pressing both buttons at the same time while the PDF is being generated so stopping is basically possible but the logger will hardly ever be stopped accidentally Stop mode disabled CAU...

Страница 23: ...le for selection Bluetooth permanently off there is no communication with the app Bluetooth permanently switched on communication with the app is possible at all times Bluetooth temporarily switched o...

Страница 24: ...omputer Measured values and alarms can be monitored via the app and it is possible to add individual information notification lines prior to generating the final PDF report Download and use of the app...

Страница 25: ...ggers The smart device displays all loggers that are in the immediate vicinity and to which a Bluetooth Low Energy BLE connection can be established If a logger is out of range or the Bluetooth functi...

Страница 26: ...selected for further operating steps by tapping the logger display symbol The selection of a logger is visually recognizable by a black border line and a black bar above the logger display symbol Tap...

Страница 27: ...port Alarm monitoring is activated by tapping Alarm On in the control panel The logger display will show the alarm bell icon with the ON status message above it Alarm monitoring is deactivated by tapp...

Страница 28: ...the control panel Entry of data into the 6 item lines is completed by START The updated content of the info fields will be exported into the PDF report and listed accordingly Note Existing entries in...

Страница 29: ...sted when access to the logger is desired This has the advantage that the respective password does not have to be entered individually for each password protected access Via the App Security Protectio...

Страница 30: ...in the list in a shortened scope of 6 characters The entries made can be edited or deleted from the list at any time General settings In the general settings the date format and the units of temperat...

Страница 31: ...tween the smart device and the logger Below are two examples of dialog information for clarification Action Start Action PDF Export 8 Disposal a Device Electronic devices are recyclable and do not bel...

Страница 32: ...1000475V01E DOC_Operation Manual LIBERO Cx BLE docx Page 32 34 9 Declaration of Conformity 9 1 EU Declaration...

Страница 33: ...tance of 20 cm between the radiator and your body This transmitter must not be co located or operating in conjunction with any other antenna or transmitter Cet appareil est conforme aux limites d expo...

Страница 34: ...e 34 34 CAN ICES 3 B NMB 3 B This Class B digital apparatus complies with Canadian ICES 003 Cet appareil num rique de classe B est conforme la norme canadienne NMB 003 IC CAN ID 9954A LIBEROCEHL ELPRO...

Отзывы: