Elok-Ori EMWLAN Series Скачать руководство пользователя страница 9

Elok-Ori Group GmbH 

  NKO 02614 Module WLAN EMWLAN 

IS

O

 

9001

:2000

 

Autor: 

Created by:  

JT 

Datum: 

Created on: 

29.6.2010 

. /: 

Document No. / Rev.: 

NKO201000194/A 

Changed by: 

JT 

Datum: 

Changed on: 

15.9.2010 

Typ dokumentu: 

Type of document: 

Custom 

Approved by: 

- - -JBödecker 

Datum: 

Approved on: 

- - - 

Status: 

State: 

In Review 

 (page) 9,(of) 10 

4. Installation 

4.1  EMWLAN modem mounting 

The electronics of the modem are imbedded in a plastic tube  with maximum diameter 45mm and 

total length 240mm. The modem can be fixed by using a holder for DIN35 rail. The holder is delivered 
optionally.      

4.2  Electrical connections 

 The  communication  interface  and  supply  are  connected  together  by  common  cable.  The 

description of the cable is shown in  table 2. 

  The  modem  is  designed  for    connection  with  another  device  with  a  non-intrinsically  safe  circuit. 

The  variants  of  the  connection  between  the  modem  and  the  other  device  are  shown  in  the  following 
pictures. 

  

 

 

Picture 4 -   EMWLAN 2.5 with the non-intrinsically  safe  external device 

 

 

 

Picture 5 -   EMWLAN 2.2 with  the non-intrinsically  safe  external device  

Содержание EMWLAN Series

Страница 1: ...CTION Module WLAN EMWLAN Contents Contents 1 1 General description 2 2 Technical specification 3 3 Operating instructions 4 3 1 Operation modes 4 3 1 1 LAN to WiFi bridge 5 3 1 1 Serial to WiFi bridge...

Страница 2: ...device with a non intrinsically safe circuit All the electronics of the device including Nano WiReach module are imbedded in a plastic tube Picture 1 EMWLAN modem The EMWLAN modem is built with two v...

Страница 3: ...cification 802 11b g VF transmit power 15 dBm VF receiver sensitivity b g 88dBm 74dBm Date rate 11Mbps 54Mbps Operation temperature 20 C to 60 C Storage temperature 20 C to 60 C Humidity 5 to 95 Diame...

Страница 4: ...orking protocol A detailed description of AT i commands is given in the ATi programmers manual pdf which is delivered by ConnectOne company The default communication parameters are set as 57600 Bd 8bi...

Страница 5: ...This mode allows the existing device with LAN connectivity to connect to a WiFi network with no driver development or application changes The modem acts as a layer 2 bridge between a LAN network and a...

Страница 6: ...BDRF 9 fix baud rate 115200Bd on RS232 but for EMWLAN modem is recommended to use the setting AT iBDRF 8 fix baud rate 57600Bd 3 2 CPU unit configuration The CPU unit configuration is performed by EM...

Страница 7: ...ity time are set to default values 57600 Bd 1000ms echo on 3 2 3 EM VER Send EM VER The version of the EMWLAN2 0 firmware 1 EM VER Cr Cr Lf VER 1 00 EMWLAN2 ETH Cr Lf Cr Lf OK Cr Lf 3 2 4 EM RESTART S...

Страница 8: ...15 9 2010 Typ dokumentu Type of document Custom Approved by JB decker Datum Approved on Status State In Review page 8 of 10 Cr Lf SETWDT 0 60 0 Cr Lf Cr Lf OK Cr Lf 3 2 6 EM DEF Send EM DEF All the l...

Страница 9: ...ter 45mm and total length 240mm The modem can be fixed by using a holder for DIN35 rail The holder is delivered optionally 4 2 Electrical connections The communication interface and supply are connect...

Страница 10: ...Created on 29 6 2010 Document No Rev NKO201000194 A Changed by JT Datum Changed on 15 9 2010 Typ dokumentu Type of document Custom Approved by JB decker Datum Approved on Status State In Review page...

Отзывы: