BeeProg3
35
Note:
Programmer need not to be switched off and also the software may be running when:
Inserting / removing AP3 programming module to / from Programming Module Interface
(PMI) connectors
Inserting / removing the target device to / from the AP3 programming module ZIF socket
but none operation with target device can be active (LED BUSY light off).
Programmer's protection electronics protect the target device and the programmer itself
against either short or long-term power failures and, partly, also against a PC failure.
However, it is not possible to grant the integrity of the target device due to incorrect, user-
selected programming parameters. Target device may be not destroyed by forced interruption
of the control program (reset or switch-off PC), by removing the physical connection to the
programmer, but the content of actually programmed cell may remains undefined.
Multiprogramming by BeeProg3
During installation of PG4UW at Select Additional Tasks window you check, if it is allowed to
install BeeProg3 multiprogramming control support.
For start of BeeProg3 multiprogramming is necessary run special control program
pg4uwmc.exe
. At this program user assign BeeProg3 to control programs, may load projects
for all BeeProg3 and run PG4UW for every connected and assigned BeeProg3.
Selftest and calibration check
If you feel that your programmer does not perform according to your expectation, please run
the programmer
Selftest
with using AP3 diagnostic POD enclosed in the standard delivery
package.
Selftest of programmer
Put together Board A with Board B of AP3 diagnostic POD
Insert
AP3 diagnostic POD
into Programming Module Interface (PMI) connectors of the
programmer site.
Run selftest of programmer in PG4UW (menu Programmer / Selftest).
AP3 diagnostic POD for Selftest plus
Содержание BeeHive304
Страница 6: ...Elnec s r o 6 Introduction ...
Страница 10: ...Elnec s r o 10 Quick Start ...
Страница 13: ...Detailed description 13 Detailed description ...
Страница 14: ...Elnec s r o 14 BeeHive304 ...
Страница 29: ...BeeProg3 29 BeeProg3 ...
Страница 43: ...Setup 43 Setup ...
Страница 48: ...Elnec s r o 48 Step 9 Installation process will start Step 10 Click Finish button to finish setup ...
Страница 58: ...Elnec s r o 58 PG4UW software ...
Страница 125: ...PG4UWMC software 125 PG4UWMC software ...
Страница 138: ...Elnec s r o 138 Installation procedure customized ...
Страница 143: ...Common notes 143 Common notes ...
Страница 148: ...Elnec s r o 148 Troubleshooting and warranty ...
Страница 152: ...Elnec s r o Jana Bottu 5 SK 080 01 Presov Slovakia www elnec com ZLI 0330 ...