40
|
www.gd-elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH
Technical Data
9
Technical Data
9.1 Continuous flow cooling (standard)
S-VSI
301
5.5 kW
7.5 kW
Sound pressure level (max.)
200 mbar (abs.)
¦
0.08 mbar (abs.)
EN ISO 3744,
Tolerance ± 3 dB(A)
dB(A)
50 Hz
79
79
60 Hz
-
85
Sound power level
dB(A)
50 Hz
87
60 Hz
89
Weight *
kg
335
340 (343)**
Length *
mm
1246
1249
Width
mm
429
429 (528)**
Height
mm
597
597
Vacuum connection
G 2
Oil filled volume
l
1.4
(0.8
¦
H + 0.6
¦
H
1
)
Cooling water consumption
max. flow temperature: 45 °C
l/min
6.7
Rated voltage 3~
V
50 Hz
400 / 690 ± 10 %
60 Hz
460 ± 10 %
Current consumption
A
50 Hz
10.2 / 5.89
14.1 / 8.15
60 Hz
-
14.3
Motor output
kW
50 Hz
5.5
7.5
60 Hz
-
9.0
* Length and weight may differ from the information listed here depending on the motor manufacturer.
** Pump with sealing gas unit
Prematic AG, Märwilerstrasse 43, 9556 Affeltrangen www.prematic.ch
Tel. 071 918 60 60, Mail: [email protected]