background image

e-mail: 

[email protected]

    internet: 

www.elmes.pl

 

Elmes Elektronik 12.2015. All rights reserved.

  

 

WIRELESS CONTROL SETS FOR ROLLERS AND GATES AUTOMATION 

                

ST100HS, ST200HS, ST100HR

 

 

This instruction manual refers to one of the following models of remote control sets: 
 

Model Type 

Set content 

Max. operating range In open field 

ST100HS 

controller S 2 transmitters DWB100HT 

100m 

ST200HS 

controller S 2 transmitters DW200HT 

200m 

ST100HR 

controller ST100HR only 

The sets are designed for remote control of window rollers/shades, automatic gates or any other equipment that uses singe phase 
powered 230VAC motors. The motor should be equipped with EOL (end of line) rotation adjustable switches. Sets features: 

 

KEELOQ

®

 code-hopping technology allowing high level of control security, 

 

operation with one or two button hand held transmitters 

– user selected by JP1, 

 

operation with all Elmes Electronic made hand held transmitters designed for 433,92 MHz band, 

 

wired control by the use of monostable wall switches, 

 

external warning/courtesy lamp (230VAC) operation modes 

– user selected by jumper JP2, 

 

automatic rolling shade/gate closure after pre-programmed PAUSE time (1sec 

 4min) 

–  user set by jumper JP3, 

 

programmable motor operation time in the range from 1 second up to 4 minutes,  

 

automatic opening while in closing mode rotation on stop made due to IR protective barrier infringement (if fitted), 

 

prolonging PAUSE time period on reset made by IR barrier infringement. 

Modes of operation 

Depending on selection made with jumper JP1 the set may be wireless controlled by the use of one or two buttons of hand trans-
mitter as described below: 

  jumper 

JP1

  shorted 

– operation control with two buttons of a hand transmitter: one for upwards rotation and stopping and 

next for downwards rotation and stopping. 

  jumper 

JP1 

opened 

– operation control with only one button of a hand transmitter: sequential use of the button will start up-

wards rotation - stop 

– downwards rotation – stop – upwards rotation – stop … etc. 

Stopping of the tube motor rotation is achieved in one of the following ways: 

a)  on any next use of hand transmitter or wall switch, 
b) 

on switching on of the motor’s end of line switch connected in series with the motor, 

c)  on passing of the motor rotation time pre-programmed by the user (1s 

 4 min),  

d)  on reset made by photo beam barrier obstacle detection (only on door/shade closing). 

On reset made by photo beam barrier obstacle detection while in closing mode, motor is stopped automatically and after one se c-
ond pause the motor starts rotation in opening direction. 

Automatic rolling door/shade closure function on/off selection with jumper JP3: 

 on jumper 

JP3 

shorted 

– automatic close function is set to 

OFF

 on jumper 

JP3 

opened 

– automatic close function is set to 

ON

. With door/shade fully opened counting of PAUSE time period is 

started and after the pause has lapsed the automatic close function is activated. Reset made by photo beam barrier obstacle de-
tection while in PAUSE mode prolongs the PAUSE time. Continued obstacle detection prohibits door closure.

 

Lamp (230VAC type) 

connected to the control unit can operate in two ways:  

 as courtesy lamp (jumper 

JP2

 shorted) 

– lights continuously at door/shade movement, and  till end of programmed PAUSE time. 

 as warning lamp (jumper

 JP2

 opened) 

– pulses slowly at door/shade opening and PAUSE time and faster in door/shade closing. 

PROGRAMMING PROCEDURES

 

1. Learning transmitter(s) to receiver's memory - max 12 (up to 112 on option): 

a)   press control unit 

PRG 

switch for less than 2 seconds (PRG LED lights on). Releasing the switch  LED continues to light 

indicating entering programming procedure, 

b)  press any transmitter button - PRG LED switches off, 
c)  press the same transmitter button again. LED in control unit starts blinking confirming end of the procedure.  
NOTE! Number of transmitters in memory is limited to 112, learning 113

th

 will remove the first, learning 114

th

 will remove sec-

ond, etc. Deleting  one transmitter from control unit memory requires deleting all transmitters and learning back remaining 
transmitters. 

2. Programming electric tube motor rotation time and PAUSE time:  

 

a)  press  control  unit 

PRG 

switch  for  more  than  2  and  less  than  8  seconds  (PRG  LED lights  on).  Releasing the switch PRG 

LED sets off. 

b)  press on hand transmitter button or wired wall switch to start motor rotation (PRG LED lights on), 
c)  when required motor rotation time has lapsed (max. 4 minutes) press the hand transmitter button or wired wall switch again 

- the electric motor stops and the courtesy/warning 

LAMP 

is sets to light on, 

d)  after required 

PAUSE

 time has lapsed press transmitter button again 

– the lamp will set off and the PRG LED starts blinking 

several times confirming end of the procedure. 

3. Deleting all transmitters from control unit memory: 

press  receiver's 

PRG 

switch  (PRG  LED lights  on)  and  hold  for  more  than  8  seconds,  until  the  receiver  LED starts  blinking 

confirming end of the procedure. The control unit memory is cleared. 

Important! 

1.  Procedure 2 above can be performed with the use of wired wall switch or transmitter learned to control unit memory. 
2.  Electric tube motor rotation time is factory set to approx. 25 seconds. Required rotation time should be programmed indi-

vidually. 

Warning!

 Activation of automatic closing function requires fitting of photo or infrared barrier protection beam securing 

obstacle free door/shade closing within movement range. 

elmes

electronic

Отзывы: