e-mail:
internet:
www.elmes.pl
Elmes Elektronik 12.2015. All rights reserved.
WIRELESS CONTROL SETS FOR ROLLERS AND GATES AUTOMATION
ST100HS, ST200HS, ST100HR
This instruction manual refers to one of the following models of remote control sets:
Model Type
Set content
Max. operating range In open field
ST100HS
controller S 2 transmitters DWB100HT
100m
ST200HS
controller S 2 transmitters DW200HT
200m
ST100HR
controller ST100HR only
-
The sets are designed for remote control of window rollers/shades, automatic gates or any other equipment that uses singe phase
powered 230VAC motors. The motor should be equipped with EOL (end of line) rotation adjustable switches. Sets features:
KEELOQ
®
code-hopping technology allowing high level of control security,
operation with one or two button hand held transmitters
– user selected by JP1,
operation with all Elmes Electronic made hand held transmitters designed for 433,92 MHz band,
wired control by the use of monostable wall switches,
external warning/courtesy lamp (230VAC) operation modes
– user selected by jumper JP2,
automatic rolling shade/gate closure after pre-programmed PAUSE time (1sec
4min)
– user set by jumper JP3,
programmable motor operation time in the range from 1 second up to 4 minutes,
automatic opening while in closing mode rotation on stop made due to IR protective barrier infringement (if fitted),
prolonging PAUSE time period on reset made by IR barrier infringement.
Modes of operation
Depending on selection made with jumper JP1 the set may be wireless controlled by the use of one or two buttons of hand trans-
mitter as described below:
jumper
JP1
shorted
– operation control with two buttons of a hand transmitter: one for upwards rotation and stopping and
next for downwards rotation and stopping.
jumper
JP1
opened
– operation control with only one button of a hand transmitter: sequential use of the button will start up-
wards rotation - stop
– downwards rotation – stop – upwards rotation – stop … etc.
Stopping of the tube motor rotation is achieved in one of the following ways:
a) on any next use of hand transmitter or wall switch,
b)
on switching on of the motor’s end of line switch connected in series with the motor,
c) on passing of the motor rotation time pre-programmed by the user (1s
4 min),
d) on reset made by photo beam barrier obstacle detection (only on door/shade closing).
On reset made by photo beam barrier obstacle detection while in closing mode, motor is stopped automatically and after one se c-
ond pause the motor starts rotation in opening direction.
Automatic rolling door/shade closure function on/off selection with jumper JP3:
on jumper
JP3
shorted
– automatic close function is set to
OFF
,
on jumper
JP3
opened
– automatic close function is set to
ON
. With door/shade fully opened counting of PAUSE time period is
started and after the pause has lapsed the automatic close function is activated. Reset made by photo beam barrier obstacle de-
tection while in PAUSE mode prolongs the PAUSE time. Continued obstacle detection prohibits door closure.
Lamp (230VAC type)
connected to the control unit can operate in two ways:
as courtesy lamp (jumper
JP2
shorted)
– lights continuously at door/shade movement, and till end of programmed PAUSE time.
as warning lamp (jumper
JP2
opened)
– pulses slowly at door/shade opening and PAUSE time and faster in door/shade closing.
PROGRAMMING PROCEDURES
1. Learning transmitter(s) to receiver's memory - max 12 (up to 112 on option):
a) press control unit
PRG
switch for less than 2 seconds (PRG LED lights on). Releasing the switch LED continues to light
indicating entering programming procedure,
b) press any transmitter button - PRG LED switches off,
c) press the same transmitter button again. LED in control unit starts blinking confirming end of the procedure.
NOTE! Number of transmitters in memory is limited to 112, learning 113
th
will remove the first, learning 114
th
will remove sec-
ond, etc. Deleting one transmitter from control unit memory requires deleting all transmitters and learning back remaining
transmitters.
2. Programming electric tube motor rotation time and PAUSE time:
a) press control unit
PRG
switch for more than 2 and less than 8 seconds (PRG LED lights on). Releasing the switch PRG
LED sets off.
b) press on hand transmitter button or wired wall switch to start motor rotation (PRG LED lights on),
c) when required motor rotation time has lapsed (max. 4 minutes) press the hand transmitter button or wired wall switch again
- the electric motor stops and the courtesy/warning
LAMP
is sets to light on,
d) after required
PAUSE
time has lapsed press transmitter button again
– the lamp will set off and the PRG LED starts blinking
several times confirming end of the procedure.
3. Deleting all transmitters from control unit memory:
press receiver's
PRG
switch (PRG LED lights on) and hold for more than 8 seconds, until the receiver LED starts blinking
confirming end of the procedure. The control unit memory is cleared.
Important!
1. Procedure 2 above can be performed with the use of wired wall switch or transmitter learned to control unit memory.
2. Electric tube motor rotation time is factory set to approx. 25 seconds. Required rotation time should be programmed indi-
vidually.
Warning!
Activation of automatic closing function requires fitting of photo or infrared barrier protection beam securing
obstacle free door/shade closing within movement range.
elmes
electronic