WIRELESS PHOTOELECTRIC SMOKE DETECTOR   MTS-166/9V

  

  (EN) 

Detector consists of autonomous battery operated audible smoke alarm and wireless alarm mod-
ule  transmitting  smoke  alarm  signal  to  alarm  control  panel  or  dedicated  receivers.  Detection  of 

smoke obscuration generates loud 85dB horn alarm along with wireless alarm transmissions to corresponding Elmes 
CB32 wireless control panel or receiver where emergency state is further notified. Operated with Elmes receivers may 
constitute a smoke alarm zone as part of any existing or newly designed security alarm system installation in house-
holds. Powered by carbon-zinc 9V battery the detector operates up to one year while up to three years operation may 
be obtained when powered by alkaline or lithium battery. When operating with Elmes CB32 panel or dedicated Elmes 
receivers CH8HR or CH20HR, the detector features monitoring of detector presence and battery voltage level. After 24 
hours of no test signal from the detector, the receivers and the control panel indicate its absence (sabotage or failure 
function). Also, low battery in the detector is indicated in the receivers and the control panel. Random timing of test and 
alarm transmissions  of the wireless module allows  many MTS detectors to be installed in close vicinity. The detector 
does not emit hazardous radiation and its operation is entirely based on photoelectric chamber obscuration by incom-
ing  smoke.  The  detector  is  intended  for  use  in  single  occupancy  dwellings  only  and  should  not  be  installed  in  public 
and industrial places. Read this leaflet fully before MTS installation and retain for future reference. 

Locating and installing smoke detectors. 

Proper location of detectors is a critical factor for early smoke detection and fire alarming. Prior to installation a judg-
ment  of  potential  fire  hazards  and  ways  of  smoke  penetration  is  recommended.  When  installing,  avoid  areas  where 
there is no air circulation e.g. corners of rooms. For maximum protection detectors should be fitted in every room. 

Smoke  detectors 

should  be  installed  in  ceiling  center

  in  sleeping 

and  living  room  areas  as  well  as  in  ways  of  expected  smoke  distribu-
tion in stair ways, hallways and their immediate vicinity. Place detector 
at  least  300mm  from  light  fittings  or  decorative  objects  that  may  ob-
struct  smoke  entering  the  detector.  When  mounting  detector  on  side 
wall, allow minimum 300mm free distance from ciling. Installing detec-
tor  in  areas  with  sloping  ceilings  or  walls  keep  900mm  distance  from 
the highest point measured. 

Do not install detector

 in room corners where there may not be suffi-

cient smoke circulation for its detection. Do not fit detectors in kitchen, 
bathroom,  workshop  or  garage  where  natural  cooking  fumes,  steam, 
dust or car exhaust fumes may trigger false alarms.

 

 

Suggested installation places of the MTS detectors in apartments and 
houses are shown on side figures 1 and 2 with detector 

marked

MTS  smoke  detector  is  battery  powered  device  and  requires  no  addi-
tional wiring. Having established a mounting location remove the base 
part by means of squeezing two clip brackets of the detector and mark 
two installation holes to be drilled in ceiling or wall. Insert supplied wall 
plugs  into  drilled  holes  and  screw  in  the  base  part.  Now  connect  9V 
battery to battery clip observing polarity and insert the battery into bat-
tery compartment at the rear of the detector. Fit the detector part to the 
base part firmly observing different widths of clip brackets.  

NOTE!  For  the  safety  of  the  end  user  the  smoke  detector  cannot 
be fitted to the base part without 9V battery installed. 

After installation or battery replacement always test correct operation of 
the 

smoke 

detector 

by 

shortly 

pressing 

center 

positioned 

TEST/SILENCE  button.  Properly  functioning  unit  emits  short  loud  sig-
nals, indicates LED pulsing and sends wireless transmissions.   

Learning detector to Elmes CB32 control panel or Elmes receivers. 

In  order  to  operate  MTS  detector  with  Elmes  made  wireless  module  it  must  be  learned  to Elmes  receiver  or  control 
panel. To do so, receiver or control panel must be set ready to learn transmitters according to procedure described in 
its  operation  manual  followed  by  MTS  detector  activation  by  pressing  its  central  placed  TEST/SILENCE  button.  Re-
ceiver/control panel confirms properly learned detecto

r by slow pulsing of its LED (receivers) or displaying “OK – cor-

rect” (CB32 control panel). Unsuccessful learning may be due to  improper learning steps or radio frequency disturb-
ance by other transmitters and should be repeated. Deleting MTS detector in receiver/control panel is done according 
to procedure steps described in their respective manuals. Maximum number of wireless detectors learned to one re-
ceiver/control panel is also specified in their manuals. 
When learning MTS detector to CB32 control panel (version 3.00 and up) it is automatically recognized as smoke de-
tector and assigned to 24hour alarm line. In emergency, control panel displays “fire alarm” message along with “line 
number” and, if the control panel operates with Elmes GSM monitoring module, appropriate SMS messages are sent 
to registered phone number. Older versions of CB32 panel would recognize the smoke detector as wireless PIR detec-