background image

Technical Support Line + 44 (0) 2392 739412

Issue 3 April 2002 - INT200E

PAK200336

ELMDENE INTERNATIONAL LIMITED

RODNEY ROAD
FRATTON
PORTSMOUTH
PO4 8SS, UK

TEL: +44 (0) 2392 739412
FAX: +44 (0) 2392 811631

INT200E Internal Sounder

High Output Internal Sounder

Internal Sounder ideal for domestic or commercial applications requiring a high siren output.

115dB(A) nominal siren output with adjustable trim control.

9-15Vdc working voltage range with polarity reversal protection.

SAB function using internal PP3 Battery (not supplied).

Battery type selectable (dry cell or rechargeable).

Ring when powered option (if required).

Selectable Positive or Negative ring input (control signal).

Hold-off supply failure detection.

Front and rear tamper.

Tamper signalling via voltfree contacts (contacts open in tamper active condition).

Designed to comply with BS EN50131-1: 1997. Security Grade: 2. Environmental Class: II.

Specification

Siren Output

115dB (A) nominal acoustic level @ 1m.

Power supply

12Vdc nominal (range: 9 - 15Vdc). Protected against polarity reversal.

Current Consumption

400mA for full alarm, 1mA standby.

Operating frequency

2.6KHz nominal (adjustable using TRIM pot over range 1.3 - 3.5KHz).

SAB Facility

9V PP3 battery, dry cell or rechargeable.

Tamper

0.5A @ 30Vdc N/O voltfree contacts

Operating temperature

-10 to +40°C (operating), -20 to +80°C (storage)

Humidity

95% RH non-condensing maximum.

Case Dimensions

160mm x 110mm x 40mm

Connections

H+

+12Vdc nominal positive hold-off supply (bell supply).

H-

0V negative hold-off supply (bell supply).

TMP 1 & 2

Tamper switch N/O contacts (contacts open in tamper active
condition).

RING

Alarm input. Selectable 0V (R-) or 12Vdc nominal (R+) to activate
sounder (unless ring when powered option selected).

BATTERY

Flying lead to PP3 type battery.

Mode Selection

JP1

Battery Type Selector: Link = PP3

RECHARGEABLE

battery

ONLY

.

No link = PP3

DRY

cell battery.

JP2

R-/R+ selection:

Link pins 1+2 (R-) , 0V to activate sounder.

Link pins 2+3 (R+), 12Vdc to activate

sounder.

Factory Default = PP3 dry cell and R- ring input

Driving Sounder from Power Supply Connection (ONLY) – Ring when
powered option

1)

Make permanent connection from H- terminal to R- terminal.

Ensure JP2 pins 1+2 linked.

2)

Unit will sound continuously when powered via H+ / H- connections.

Installation and Set-up

1)

Remove sounder cover.

2)

Remove knock-outs from sounder baseplate as required.

3)

Adjust tamper switch blade as required.

4)

Select required PP3 battery type using JP1 jumper link (dry cell or rechargeable).

5)

Select required RING (control) signal polarity using JP2 jumper link.

6)

Pass wires from control panel through knock-out hole(s).

7)

Fix backplate to wall with screws through mounting slots.

8)

Set ‘TRIM’ control pot. to mid position.

9)

Connect RING terminal of sounder to ring (bell) output of control panel (unless sounder driven
from single power supply connection – see above).

10)

If Tamper circuit used, connect TAMP1/2 terminals to appropriate inputs on control panel.

11)

Connect n12Vdc and 0V supply from control panel to H+ and H- terminals
respectively.

12)

Replace sounder cover.

Testing

Sounder driven from Power Supply Connection – Ring when powered option

1)

Connect sounder to n12Vdc and 0V supply (from control panel) if single connection
used.

2)

Check output from sounder. Remove cover and adjust ‘TRIM’ control pot. as required. Replace
cover.

Conventional Panel Connections

1)

Activate ring (bell) output from control panel and check output from sounder. Remove cover
and adjust ‘TRIM’ control pot. as required.

2)

Check that the panel detects a tamper failure, if tamper connections used.

3)

Replace cover. Check that the tamper active output condition has cleared at the control panel.

4)

Fasten cover screw.

CAUTION

This unit is NOT SUITABLE for

external installation.

Risk of explosion if dry cell

battery used with JP1 link

fitted.

Dispose of used batteries

according to the battery

manufacturer’s

instructions and all local and

national regulations.

TAMPER
SWITCH

JP2 LINK
(RING POLARITY)

JP1 LINK (FIT FOR
RECHARGEABLE
PP3 BATTERY)

TRIM POT
CONTROL

PP3 BATTERY
Note: Ensure
battery locates
hard against
(central) end stop.