Operation
WARNING
: Risk of electrocution. High-voltage circuits, both AC and DC, are very
dangerous and should be measured with great care.
1.
ALWAYS turn the function switch to the OFF position when the meter is not in use.
This meter has Auto OFF that automatically shuts the meter OFF if 15 minutes elapse
between uses.
2.
If “OL” appears in the display during a measurement, the value exceeds the range
you have selected. Change to a higher range.
NOTE
: On some low AC and DC voltage ranges, with the test leads not connected to a
device, the display may show a random, changing reading. This is normal and is caused
by the high-input sensitivity. The reading will stabilize and give a proper measurement
when connected to a circuit.
MODE BUTTON
To select Diode/Continuity or DC/AC voltage, current,Temperature(C/F)
RANGE BUTTON
When the meter is first turned on, it automatically goes into AutoRanging. This
automatically selects the best range for the measurements being made and is generally
the best mode for most measurements. For measurement situations requiring that a range
be manually selected, perform the following:
1.
Press the RANGE button. The “AUTO” display indicator will turn off.
2. Press the RANGE button to step through the available ranges until you select the range
you want.
3. Press and hold the RANGE button for 2 seconds to
exit the ManualRanging mode and return to AutoRanging.
DATA HOLD BUTTON
The Data Hold function allows the meter to "freeze" a measurement for later reference.
1.
Press the DATA HOLD button to “freeze” the reading on the indicator. The indicator
“HOLD” will be appear in the display.
2. Press the DATA HOLD button to return to normal operation.
MAX HOLD BUTTON
The max. Hold position is used to measure the maximum value. The maximum measured
value is up dated continuously. Press once again the button, will release the hold and
allow a further measurement.