How to replace components
on the generator print
74
SM/Transsonic_LC/1104/D
© Elma GmbH & Co KG
15
How to replace components
on the generator print
15.1
T310 – T420H; LC20H – LC30H
If the fuse is blown there usually are faulty transistors (short
circuit).
200 000 5002
Transistors
Elma Order No.
1. Loosen the generator print from the bottom plate.
How to proceed
2. Unsolder the transistors.
3. Loosen the M3 nut on the cooling body.
4. Remove the transistors.
5. Check the diodes for short circuits; replace if necessary.
6. Check the resistances 100 Ohm and 1.2 Ohm for
throughline; replace if necessary.
7. Screw and solder in new transistors.
8. Adjust the generator (
see section 16.4.
).
There can be a short circuit in mains diode BZW 06 due to
extreme voltage peaks or a mains overvoltage (fuse and BZW
diode faulty). In this case, no other components are faulty.
200 000 0353
The diodes (BA 159 or 1N4007) can be faulty due to a short
circuit of the transistors.
BA 159: 200 000 6123
1N 4007: 200 000 5001
The capacitor in the output circle (2kV) can be destroyed due to
a fault in the transducer system or through wrong operation
(cleaning items directly on the tank floor). The ultrasonic
frequency is undefined around 50kHz.
200 000 0015
The resistances 1.2 Ohm / 4W; 100 Ohm / 0.5W or
18 kOhm / 1W can be faulty due to a short circuit of the
transistors.
Check with ohmmeter.
1,2 Ohm / 4W: 200 000 5004
100 Ohm / 0,5W: 200 000 5005
18 kOhm / 1W: 200 000 5033
BZW diode
Elma Order No.
Diodes
Elma Order No.
Capacitor
Elma Order No.
Resistances
Elma Order No.