Battery and Fuse replacement
Battery use:
1.5V AAA Size battery x 2
Fuses use:
Fuse (F2) for
AmA current input:
0.4A/1000V ac & dc, IR 30kA, F fuse; Dimension: 6 x 32
mm
Fuse (F1) for A current input:
11A/1000V ac & dc, IR 20kA, F fuse; Dimension: 10 x 38
mm
Battery and Fuse replacement:
Loosen the screw from the access cover of the case
bottom. Lift the access cover. Replace the batteries or
fuse. Re-fasten the screw.
General specifications
Display:
3-5/6 digits 6,000 counts
Update Rate:
5 per second nominal
24 Segments Bar graph:
40 per second max
Operating Temperature:
0
o
C to 40
o
C
Relative Humidity:
Maximum relative humidity 80% for temperature up to 31
o
C decreasing
linearly to 50% relative humidity at 40
o
C
Altitude:
Operating below 2000m
Storage Temperature:
-20
o
C ~ 60
o
C, < 80% R.H. (with battery removed)
Temperature Coefficient:
Nominal 0.15 x (specified accuracy)/
o
C @ (0
o
C ~ 18
o
C or 28
o
C ~
40
o
C), or otherwise specified
Sensing:
Average sensing
Pollution Degree:
2
Safety:
Double insulation per IEC/UL/EN61010-1 Ed. 3.0, IEC/EN61010-2-030 Ed. 1.0,
IEC/EN61010-2-033 Ed. 1.0, IEC/UL/EN61010-031 Ed. 1.1 and CAN/CSA-C22.2 No. 61010-1-12
Ed. 3.0 to Category II 1000V, CAT III 600V and CAT IV 300V AC & DC
Transient Protection:
6kV (1.2/50
s surge)
Terminals (to COM) Measurement Category:
V / mA
A / A: Category II 1000V, CAT III 600V and CAT IV 300V AC & DC.
E.M.C. :
Meets EN61326-1:2006 (EN55022, EN61000-3-2, EN61000-3-3, EN61000-4-2,
EN61000-4-3, EN61000-4-4, , EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11)
In an RF field of 3V/m:
Capacitance function is not specified
Other function ranges:
Total Accuracy = Specified Ac 100 digits
Performance above 3V/m is not specified
Overload Protection:
A & mA :
0.4A/1000V DC/AC rms, IR 30kA, F fuse
A :
11A/1000V DC/AC rms, IR 20kA, F fuse
V :
1100V DC/AC rms
mV, Ohm & others :
1000V DC/AC rms
Low Battery:
Below approx. 2.3V
Power Supply:
1.5V AAA Size battery X 2
Power Consumption (typical):
4.3mA
APO Consumption (typical):
10
A
APO Timing:
Idle for 34 minutes