MP500/4N-8-16 Programming
9
1 - CONTROL DEVICES
This chapter contains a description of the devices which allow to access the alarm system locally, to arm or disarm the system, to
program and to interact with it.
The function of the various keys and the information supplied by the LEDs and on the display are explained for keypads.
The information supplied by the LEDs is provided for readers.
1.1
KP500D/N - KP500DV/N KEYPAD DISPLAY
Figure 1 - KP500D/N and KP500DV/N keypads
Ref.
Description
Use or indications provided
A
Alphanumeric keys
For entering the access code, arming or disarming the system, programming the system.
B
Function keys
For activating fire, emergency and silent panic indications.
C
LCD 2 x 16 characters
Date and time or detailed information on system status is shown in stand-by mode
*
. Menus and
system parameters and information are shown during system programming or querying.
D
Navigation keys
These are used to go from one menu item to another. They change the value of some
parameters.
E
MENU
key
To access the menu.
F
ESC
key
To go back to the upper menu level.
G
OK
key
To confirm the access code and other entered data.
To confirm the chosen menu and go to the submenu.
H
Lid
To protect the alphanumeric keys.
*
Displaying information other than date and time in stand-by mode declasses EN50131 certification from grade 3 to grade 2.
Table 1 - KP500D/N and KP500DV/N keypad elements
1.1.1
Function keys
Symbol
KP500D/N and KP500DV/N
Associated function
Fire indication
Emergency indication
Silent panic indication
Table 2 - KP500D/N and KP500DV/N keypad function keys
A
B
C
G
D
E
F
H
Содержание MP500/16