86
MP500/4N-8-16 Programming
5.8.4
Partial disarming (system with areas and partitions)
Proceed as follows to arm the entire alarm system if areas are defined:
1) Enter
<Master / User / Installer / Technical Manager code >
and press
.
2) Press
F1
for areas or
F4
for partitions. Press
F1
(i.e. areas) on the display. An empty square will
appear for each programmed area which is not armed assigned to the keypad and code. Full squares
indicate that the area is armed. Half-full squares indicate that the area is only partially armed.
3) The keypad will beep. Press
to exit without disarming.
4) Press the function keys (
F1
,
F2
,
F3
and
F4
) positioned under the areas to be disarmed:
5) After 5 seconds, the status LED will switch off and the squares will become empty indicating that the
areas have been disarmed. The following will appear on the display:
6) Press
if you do not want to wait for 5 seconds.
IMPORTANT!
The user will disarm only the assigned areas and not necessarily all the areas even
with this procedure.
7) If
F4
was pressed, the following will appear on the display:
8) Enter the number of the partitions to be disarmed on the keypad: the respective squares will become
empty.
9) After 5 seconds, the status LED will switch off and the squares will become empty indicating that the
partitions have been disarmed. The following will appear on the display:
10) Press
if you do not want to wait for 5 seconds.
11) The display will go back to standard view automatically after one minute. Press
to go to
standard view immediately.
IMPORTANT!
The user will disarm only the assigned partitions and not necessarily all the
partitions even with this procedure.
5.8.5
Disarming from keypad under hold-up
On MP500/4N, MP500/8 and MP500/16 control panels, starting from control panel SW version 1.01, if the hold-up function has been
enabled (see paragraph 2.1.4
How to enable the hold-up function
) and you are threatened and forced by a criminal with the risk of life
then, you can disarm the burglar system while arming the hold-up alarm simultaneously which will make the dialer sending the
programmed alarm messages without activating the siren sound.
To disarm the system when your are under coercion, just increase your user code of one digit. For example if your user code is 000021
you need only to enter 000022; if user code is 29 enter 30, if it is 39 enter 40, etc.
IMPORTANT!
Enabling the hold-up function will cancel EN50131 compliance.
IMPORTANT!
Simply enter the number directly if nine or fewer partitions have been programmed.
If more than nine partitions have been programmed, always enter two digits to select the partitions,
including for numbers from 1 to 9 (1 = 01, 2 = 02 etc.).
DISARM
DISARM
DISARM
EXECUTED
EXECUTED
DISARM
AREAS
PART
Содержание MP500/16
Страница 139: ...MP500 4N 8 16 Programming 139 ...