MP500/4N-8-16 Programming
79
5.4.2.2
System in use mode = Mode 2 or Mode 0
Proceed as follows to arm all partitions assigned to the reader and to the key using the proximity key:
1. Approach the proximity key in the reader when all the green LEDs are off (the procedure will disarm the partitions if any LEDs are
green). The red LED will blink to indicate that the key is being read. All the green LEDs will blink rapidly if the key is not recognised.
2. Move away the proximity key when the red LED starts blinking.
3. The green LEDs indicate the status of the partitions assigned to the reader.
LED on fixed
= partition armed,
LED off
= the key is not
assigned to the partition and cannot arm it.
IMPORTANT!
The key will arm only the assigned partitions and not necessarily all the partitions even with this procedure.
5.4.3
Total arming from KP500DP/N keypad
Proceed as follows to arm all partitions using the proximity key on a KP500DP/N keypad:
1) Approach the proximity key to the keypad transponder.
2) The keypad will beep. Press
to exit without arming.
3) The status LED will light up after 5 seconds (fixed if all partitions are armed, blinking if only some
partitions are armed). The square will appear full indicating the partitions which have been armed. The
following will appear on the display:
4) The display will go back to standard view automatically after one minute. Press
to go to standard
view immediately.
IMPORTANT!
The key will arm only the assigned partitions and not necessarily all the partitions even with this procedure.
IMPORTANT!
The LED
H
/ST keypad) will light up and the buzzer will sound to indicate
an error (long beep) if a key which can be not been acquired (the key is not recognised) or which has not been enabled is used.
5.4.4
Partial arming from electronic key reader
5.4.4.1
System in use mode = Mode 3 (EN50131 grade 3 compliant)
Proceed as follows to arm only the partitions assigned to the reader and to the key using the electronic key:
1. Insert the electronic key in the reader. The red LED will blink to indicate that the key is being read and the green LED will light up
after a few instants to indicate that the key was recognised. All the green LEDs will blink rapidly if the key is not recognised.
2. The green LEDs corresponding to the armed partitions, if any, will appear if the key is recognised. The red LED will keep blinking.
3. Extract the key.
4. Insert the electronic key again when the red LED switches off.
5. The red LED will blink and after a few seconds a cycle will start during which the green LEDs blink for a few seconds showing the
various combinations of partitions in sequence.
6. Extract the electronic key when the combination of partitions to be armed is displayed by the LEDs. The possibility of arming each
partition depends on the programming of the reader and on the key used.
7. The chosen partitions will be armed and the green LEDs will indicate the status of the partitions assigned to the reader for a few
seconds.
IMPORTANT!
The key will arm only the assigned partitions and not necessarily all the partitions even with this procedure.
EXECUTED
ARM
PARTITIONS
Содержание MP500/16
Страница 139: ...MP500 4N 8 16 Programming 139 ...