MP500/4N-8-16 Programming
77
5.3.3
Partial arming (system with partitions only)
Proceed as follows to arm the entire alarm system partially if no areas are defined:
1) Enter
<Master / User / Installer / Technical Manager code >
and press
.
2) The keypad will beep. Press
to exit without arming.
3) Enter the number of the partitions to be armed on the keypad: the respective squares will become full.
IMPORTANT!
Simply enter the number directly if nine or fewer partitions have been programmed.
If more than nine partitions have been programmed, always enter two digits including for numbers
from 1 to 9 (1 = 01, 2 = 02 etc.).
4) The status LED will light up after 5 seconds (fixed if all partitions are armed, blinking if only some
partitions are armed). The square will appear full indicating the partitions which have been armed. The
following will appear on the display:
IMPORTANT!
The user will arm only the assigned partitions and not necessarily all the
partitions even with this procedure.
5) The display will go back to standard view automatically after one minute. Press
to go to
standard display immediately.
6) If programmed or if the system is EN50131 compliant, the keypad will sound long beeps initially
followed by short beeps for the last 10 seconds.
5.3.4
Partial arming (system with areas and partitions)
Proceed as follows to arm the entire alarm system partially if areas are defined:
1) Enter
<Master / User / Installer / Technical Manager code >
and press
.
2) Press
F1
for areas or
F4
for partitions. Press
F1
(i.e. areas) on the display. An empty square will
appear for each programmed area which is not armed assigned to the keypad and code. Full squares
indicate that the area is armed. Half-full squares indicate that the area is only partially armed.
3) The keypad will beep. Press
to exit without arming.
4) Press the function keys (
F1
,
F2
,
F3
and
F4
) positioned under the areas to be armed: the respective
squares of the areas will become full.
5) The status LED will light up after 5 seconds (fixed if all areas are armed, blinking if some areas are not
armed). The following will appear on the display:
6) Press
again if you do not want to wait for 5 seconds.
IMPORTANT!
The user will arm only the assigned areas and not necessarily all the areas even
with this procedure.
7) If
F4
(i.e. partitions) was pressed at the beginning of the procedure, an empty square will appear on
the display for each programmed partition assigned to keypad and code which is not armed. Full
squares indicate that the partition is armed. Circles indicate that the partition is disarmed and has open
inputs.
8) The keypad will beep. Press
to exit without arming.
9) Enter the number of the partitions to be armed on the keypad: the respective squares will become full.
IMPORTANT!
Simply enter the number directly if nine or fewer partitions have been programmed.
If more than nine partitions have been programmed, always enter two digits including for numbers
from 1 to 9 (1 = 01, 2 = 02 etc.).
ARM
EXECUTED
ARM
ARM
EXECUTED
ARM
AREAS
PART
Содержание MP500/16
Страница 139: ...MP500 4N 8 16 Programming 139 ...