MP500/4N-8-16 Programming
63
4.18.10.1
Programming procedure
Proceed as follows to program the PSTN line test:
1) Enter
<Installer code>
, press
, then
and finally
repeatedly until TELEPHONE DIALER
appears.
2) Press
and then
several times until PSTN LINE TEST appears.
3) Press
. Press
and
to select DISABLE, 24 H, SYSTEM ON or ATS4. Press
to
confirm.
4) Press
repeatedly to exit from the menu.
4.18.11
Period Comm Test
MP500/xx control panels can automatically call the alarm receiving or remote control centres at predetermined intervals of time if
periodical confirmation of correct system operation is required.
This test function is not mandatory but strongly recommended.
The possible alternatives are:
Disable
: no calls are made.
24h
: the check is carried out even when the system is disarmed at the chosen interval of time starting from the set time. The call is
made to the associated telephone number. Possible intervals of time are 1, 4, 8, 12, 24, 48, 72, 96, 120, 144, 168 hours.
System ON
: the check is carried out only if all the configured partitions are armed at the chosen interval of time starting from the
set time. The call is made to the associated telephone number. Possible intervals of time are 1, 4, 8, 12, 24, 48, 72, 96, 120, 144,
168 hours.
IMPORTANT!
The "Period Comm Test" function does not need to be enabled for EN50131 grade 3 compliance because this
function must be managed by the external communicator (ATS4) which must be connected.
If the control panel must be EN50131 grade 2 compliant (e.g. if the ATS4 external communicator is not installed), the "Period
Comm Test" function must be set to 24h with a frequency of less than 24 hours.
4.18.11.1
Programming procedure
Proceed as follows to program the Period Comm Test function:
1) Enter
<Installer code>
, press
, then
and finally
repeatedly until TELEPHONE DIALER
appears.
2) Press
and then
several times until PERIOD COMM TEST appears.
3) Press
. Press
and
to select DISABLE, 24 H or SYSTEM ON. Press
to confirm.
4) The screen page shown here by the side will appear if 24H or SYSTEM ON is selected.
5) Press
. Press
and
to select the telephone number of the alarm receiving centre. Press
to confirm.
6) Press
.
7) Press
. Enter the time in hh:mm (24 hour) format directly using the number keys using an initial
0 if needed. If you make a mistake press
and access the SET HOUR menu. Press
to
confirm the entered time.
8) Press
.
9) Press
. Press
and
to select the interval of time between calls. Press
to confirm.
10) Press
repeatedly to exit from the menu.
UT00:INSTALLER
TELEPHONE DIALER
TELEPHONE DIALER
PSTN LINE TEST
PSTN LINE TEST
24 H
UT00:INSTALLER
TELEPHONE DIALER
TELEPHONE DIALER
PERIOD COMM TEST
PERIOD COMM TEST
DISABLE
24H
ASSIGN TEL N.
ASSIGN TEL N.
T01:...
24H
SET HOUR
24H
HOUR 10:24
24H
INTERVAL
INTERVAL
1h