44
MP500/4N-8-16 Programming
4.13 KEYPAD PROGRAMMING
The keypad programming procedure is described below. It is important to note that some functions are only available on vocal keypads
KP500DV/N.
4.13.1
Functions to be configured
Gong function
: audible buzz indication from the keypad when an input with ancillary gong function enabled is opened when the
system is disarmed.
Sound time entry
: auditory indication provided by the keypad buzzer of the elapsing entry time when the system is disarmed.
Sound time exit
: auditory indication provided by the keypad buzzer of the elapsing exit time when the system is armed.
Masking
: this hides system status (armed or disarmed) when it is enabled. The specific LED is off and nothing appears
on the keypad display. System status may be checked when the masking function is enabled by entering a valid code
on the keypad.
IMPORTANT!
Do not enable masking to maintain EN50131 compliance. The LEDs are managed directly by the control panel.
Function keys
: this is used to enable or disable the
“Fire”, “Silent Panic” and “Emergency” keys on the keypad. By holding these keys
pressed for at least three seconds, the control panel generates the respective alarm without needing to enter any code.
4.13.2
Emergency indication
In case of emergency indication (from emergency input, key or "lack of move"), the system will automatically activate the environmental
listening function on the vocal keypad after having sent the pre-recorded vocal message.
The called user can listen to the voices and noises in the keypad surroundings.
DTMF controls (see paragraph
List of VOCAL answer machine DTMF controls
and following) can be used to alternate listening and
talking or to listen to the environmental noises in the surroundings of other vocal keypads.
IMPORTANT!
The automatic listening function can only be activated on the preferred keypad if there are several keypads.
The automatic listening function at end of call is activated directly on a vocal keypad on which the emergency key was pressed if the
emergency indication was activated in this manner (the “ENVIR. LISTENING” programming is ignored).
The
automatic listening function at end of call is activated directly by the keypad on which “ENVIR. LISTENING” is enabled (the
programming is respected) if the emergency indication was activated by pressing the emergency key of a keypad without vocal
functions.
4.13.3
Programming procedure
Proceed as follows to program the emergency indication:
1) Enter
<Installer code>
, press
, then
and finally
repeatedly until PROGRAMMING
appears.
2) Press
and then
several times until KEYPADS appears.
3) Press
.
4) Press
and
to select the required keypad. Press
to confirm.
5) Press
. Press
and
to assign the keypad to the SYSTEM (all partitions) or only to some
PARTITIONS. Press
to confirm.
6) If SYSTEM is selected, press
and
to select SYSTEM ASSIGN or SYSTEM DO NOT
ASSIGN and press
to confirm. Then
.
7) The screen page shown here by the side will appear if PARTITIONS is selected. The empty boxes
represent partitions which are not assigned to the keypad and the black boxes the partitions which
have already been assigned. Press
and
to select the partition to be associated. Press
and
to assign the partition (the square will turn black) or to disassociate it (the square will
appear empty). Repeat the procedure for all partitions to be associated to the keypad. Press
at the end. Then
.
UT00:INSTALLER
PROGRAMMING
PROGRAMMING
KEYPADS
KEYPADS
KP01:KP 01
KP01:KP 01
ASSIGN
ASSIGN
SYSTEM
SE##:
□□□□□■□
Содержание MP500/16