42
MP500/4N-8-16 Programming
O COMMANDABLE
The commandable output is EN50131 compliant when:
it is activated by a timed programmer output activation command.
it is deactivated by a timed programmer output deactivation comand.
The commandable output may be activated but cancels EN50131 compliance when:
it is activated/deactivated via SMS text message
it is activated/deactivated remotely by dialling an appropriate DTMF sequence
the control panel is called on the GSM network from the telephone number to which the zero-cost call function is associated
the “
+
” key on the remote control is pressed.
O DOOR OPENER
The door opener output is activated when a door opener event is generated.
O COURTESY LIGHT
The courtesy light output is activated when a courtesy light event is generated.
O PULSED COMM.
Pulsed output is activated for approximately 1 second.
The pulsed commandable output is EN50131 compliant when:
it is activated by a timed programmer output activation command.
The pulsed commandable output may be activated but cancels EN50131 compliance when:
it is activated via SMS text message
it is activated remotely by dialling an appropriate DTMF sequence
the control panel is called on the GSM network from the telephone number to which the zero-cost call function is associated
the “
+
” key on the remote control is pressed.
4.12.5
Programming procedure
IMPORTANT!
Changes to the default customisations of the control panel outputs could cancel EN50131 compliance.
Proceed as follows to program the outputs:
1) Enter
<Installer code>
, press
, then
and finally
repeatedly until PROGRAMMING
appears.
2) Press
and then
several times until OUTPUTS appears.
3) Press
.
4) Press
and
to select the required device. Press
to confirm.
5) Press
and
to select the required output. Press
to confirm.
6) Press
. Change the logical address using keys
and the numeric keypad. Press
to
confirm.
IMPORTANT!
There cannot be two outputs with the same logical address.
IMPORTANT!
Commandable outputs must have a logical addresses comprised between
01 and 10.
7) Press
.
8) Press
and
to select the output type. Press
to confirm.
9) Press
.
UT00:INSTALLER
PROGRAMMING
PROGRAMMING
OUTPUTS
OUTPUTS
CONTROL PANEL
CONTROL PANEL
UC.U!: U01
UC.U1: U01
LOGIC NUMBER
LOGIC NUMBER
Uo1:...
UC.U1: U01
OUTPUT TYPE
OUTPUT TYPE
OUTPUT N.H.
UC.U1: U01
ASSIGN