4 - SYSTEM COMMISSIONING
This chapter describes the programming needed to commission the burglar alarm system at the end of installation and to connect the
various devices.
Programming may be carried out by means of a system keypad, a service keypad (see
Installation Manual
for more information on
connections) or a PC provided with Hi-Connect software and connected to the control panel by means of a USB cable and optional
interface (see
Installation manual
for more information on connections).
The control panel may be programmed at a workshop and the programming may later transferred on site using a USB flash drive and
optional interface.
This chapter describes the programming procedures for keypads with LCD. The programming procedure on the KP500DP/N or
KP500D/ST touchscreen keypad is the same but the information shown on the OLED may be slightly different.
4.1
CONVENTIONS USED IN PROGRAMMING PROCEDURES
Programming is carried out using the keys and reading the messages and information which appear on the display.
The main functions associated to the keys are:
To access the menu
Confirms the entered parameter, accesses the displayed submenu or confirms the selection made
Goes back to the previous page or menu level
Scrolls the menu items, edits a value
Scrolls the menu items, edits a value
Moves the cursor along the writing line
Moves the cursor along the writing line
The following step-by-step programming and configuration procedures show the keys to be pressed and what appears on the display.
Text is limited to the essential minimum. The concerned function, the parameters to be configured, what the parameters are for and the
possible values are described before each procedure.
<Master code>
<User code>
<Technician code>
<Technical Manager code>
This indicates the code to be entered using the keypad.
<Master / User / Installer /
Technical Manager code>
This means that either code may be entered on the keypad indifferently.
It is indicated whether each procedure is EN50131 grade 3 compliant or not.
The indication is hierarchic: this means that an indication provided in a parameter applies to the parameter below it unless otherwise
indicated.