MP500/4N-8-16 Programming
21
2.1.1
Default access codes
The MP500/4N, MP500/8 and MP500/16 control panels are provided with default codes when they leave the factory.
The Installer and Technical Manager codes are enabled at the factory and automatically deactivated when a valid Master or Use r code
is entered for the first time.
Code type
Level
Default code
Associated partitions
Enabled when
leaving the factory
Enable time
(once enabled)
Installer
3
000000
All
Yes
Temporary session
Master
2
111111
All
Yes
Permanent
User (2
14)
2
000020-000140
Partition 1
No
Until expressly
disabled
Technical Manager
3
222222
All
Yes
Temporary session
Table 9 - Default access codes for MP500/4N
Code type
Level
Default code
Associated partitions
Enabled when
leaving the factory
Enable time
(once enabled)
Installer
3
000000
All
Yes
Temporary session
Master
2
111111
All
Yes
Permanent
User (2
31)
2
000020-000310
Partition 1
No
Until expressly
disabled
Technical Manager
3
222222
All
Yes
Temporary session
Table 10 - Default access codes for MP500/8
Code type
Level
Default code
Associated partitions
Enabled when
leaving the factory
Enable time
(once enabled)
Installer
3
000000
All
Yes
Temporary session
Master
2
111111
All
Yes
Permanent
User (2
62)
2
000020-000620
Partition 1
No
Until expressly
disabled
Technical Manager
3
222222
All
Yes
Temporary session
Table 11 - Default access codes for MP500/16
2.1.2
Code change
Each user can change their access code freely.
Proceed as follows to change the code:
1) Enter <Master / User / Installer / Technical Manager code>, press
and then
.
2) Press
repeatedly until SETTINGS appears.
3) Press
and then
several times until CHANGE CODE appears.
4) Press
.
5) Enter the new code, from four to six digits, and press
.
IMPORTANT!
Trough the use of the web server only 6-digit codes are allowed.
IMPORTANT!
Any access code shorter than six digits will cancel EN50131 grade 3
compliance of the entire burglar alarm system.
If there are no other limiting factors, five or six digit access codes allow EN50131 grade 2
compliance.
Four digit codes will cancel EN50131 compliance.
UT02:...
SYSTEM STATUS
UT02:...
SETTINGS
SETTINGS
CHANGE CODE
CHANGE CODE
NEW: ------