128
MP500/4N-8-16 Programming
10.3 IDP MESSAGE STRUCTURE
One message is sent for each single event. Several events will be sent in the same telephone call, if applicable.
For example, messages related to each partition concerned by an arming or disarming event will be sent in sequence in the same
telephone call because the global system arming or disarming does not exist as an event.
The message string structure is applicable for all events.
A
A
A
A
1
8
Q
E
E
E
G
G
C
C
C
S
Rem.Ctrl Code
FIXED
Qualification
Event
Group
Code or input ID
Cks
Where:
Block
Code
Description
Rem.Ctrl Code
xxxx
these are the last four digits of the remote control code
Qualification
1
this indicates the beginning of an event or disarming
3
this indicates the end of an event or arming
Event
100
emergency alarm from input
101
emergency alarm from function key on keypad
110
fire alarm from input
111
fire alarm from function key on keypad
120
panic alarm from input
121
hold-up alarm from input
122
silent panic alarm from input or from function key on keypad
130
hold-up alarm from input and way (route) input (entry / way / exit)
137
tamper input alarm
138
input pre-alarm
145
control panel and/or peripheral device tamper alarm
150
technological event 1 from input
151
technological event 2 from input
152
technological event 3 from input
300
failure alarm from failure input
301
lack of power alarm
302
low battery alarm
307
power failure alarm
320
siren failure
330
control panel bus communication to peripheral device error alarm
344
jamming alarm (in presence of radio expansion module only)
351
PSTN telephone failure alarm
354
GSM telephone failure alarm
355
no supervision alarm (in presence of radio expansion module with devices only)
380
detector failure
388
jamming
401
arming/disarming from user code, key, remote control
403
arming/disarming from timed programmer
407
arming/disarming from remote with DTMF code or Hi-Connect
409
arming/disarming from key input
450
arming with overriding
454
partitions not armed because more than 70% of the total inputs are open or isolated in presence of
faults, tampering
458
maintenance (installer working on site)
461
wrong code alarm
570
input isolation
573
input inhibition
601
manual test call
602
cycle test call
Group
00
the event refers to the entire system
01 ÷ 16
the event is referred to partitions 1 - 16
Table 16 - IDP message structure