104
MP500/4N-8-16 Programming
7.2.10
Detector jamming alarm
Monitoring of devices provided with fault output can be implemented in combination on control panels.
This is generated
when...
If one or more customised jamming inputs are open.
It activates...
The programmed detector fault outputs which have at least one partition in common with the input which
generated the event (with partition armed).
The dialler to send the respective alarm message (if programmed) in form of numeric code, vocal call or
modem communication.
It is stored...
In the Diagnose Log and in the fault and anomaly memory.
It is indicated...
On fault LED of keypads which have at least one partition in common with the input which generated the
event.
On readers which have at least one partition in common with the input which generated the event.
After having solved the
problem, the control
panel...
Stores end of fault in the Diagnose Log.
Deactivates the programmed fault detector outputs.
7.2.11
Detector fault alarm
Monitoring of devices provided with fault output can be implemented in combination on control panels.
This is generated
when...
If one or more customised detector fault inputs are open.
It activates...
The programmed detector fault outputs which have at least one partition in common with the input which
generated the event (with partition armed).
The dialler to send the respective alarm message (if programmed) in form of numeric code, vocal call or
modem communication.
It is stored...
In the Diagnose Log and in the fault and anomaly memory.
It is indicated...
On fault LED of keypads which have at least one partition in common with the input which generated the
event.
On readers which have at least one partition in common with the input which generated the event.
After having solved the
problem, the control
panel...
Stores end of fault in the Diagnose Log.
Deactivates the programmed fault detector outputs.
7.2.12
Faulty siren alarm
Monitoring of devices provided with fault output can be implemented in combination on control panels.
This is generated
when...
One or more customised siren fault inputs are open.
It activates...
The programmed system fault outputs which have at least one partition in common with the input which
generated the event.
The dialler to send the respective alarm message (if programmed) in form of numeric code, vocal call or
modem communication.
It is stored...
In the Diagnose Log and in the fault and anomaly memory.
It is indicated...
On fault LED of keypads which have at least one partition in common with the input which generated the
event.
On readers which have at least one partition in common with the input which generated the event.
After having solved the
problem, the control
panel...
Stores end of fault in the Diagnose Log.
Deactivates the programmed failure outputs.