MEDEA Programming Manual
113
8.9
Tamper Memory menu
This shows the stored tampering alarms, from the most recent to the oldest.
Available for Master, User, Installer.
It is accessed through the
Main menu
→ MEM TAMPER menu.
Use the
▼ and ▲ buttons to scroll through the various stored tampering events.
Each alarm event is displayed with a sequential number, the time and date it occurred (
hh:mm
and
dd/mm
)
and an abbreviated description (
Short Descr
).
Press the
OK
button to open the submenu to display the details of the tampering event. Use the
▼ and ▲
buttons to scroll through the various submenu screens.
The first screen shows the complete description of the tampering event (Long descr.), the physical address
of the device (UC = control panel, EP = expansion module, KP = keypad, DK = key reader) and the custom
description (Label).
The second indicates the concerned sector.
The third shows the device type (Device).
Press the
ESC
button to go back to the stored tampering event list.
You can clear the entire tampering event memory list by pressing the
OK
button when "DELETE
MEMORY?" message appears on the display.
0001 hh:mm dd/mm
Short descr.
0002 hh:mm dd/mm
Short descr.
0003 hh:mm dd/mm
Short descr.
...
DELETE
MEMORY?
Long descr.
ind:Label
SECTORS
■□□□□□□□□□□□□□□□
Type
ind:Label
▼ ▲
OK
▼ ▲
▼ ▲
▼ ▲
▼ ▲
▼ ▲