MEDEA Installation Manual
83
6.4.7
Deleting wireless devices from an individual ER700-RF receiver
Proceed as follows to reset a single ER700-RF receiver.
From the configurator (using the technician code):
1. Enter the configurator
2. Select
CONFIGURATION
→
Bus Peripherals
→
Radio Expansions
.
3. Delete the wireless devices acquired by the ER700-RF using the appropriate command
Important: It is not necessary to reset the wireless sensors/sirens.
6.4.8
Deleting ZigBee devices
Proceed as follows to delete the ZigBee devices.
From the configurator (using the technician code):
1. Enter the configurator
2. Select
CONFIGURATION
→
Bus Peripherals
→
Search Peripherals.
3. Delete the ZigBee device using the appropriate command
6.5
Functions associated with SW2 DIP switches on the CPU
board
DIP switch
Position
Function
1
ON
System under maintenance
OFF
Normal operation
2
ON*
Reset codes
OFF
Normal operation
3
ON*
Global reset
OFF
Normal operation
4
ON
Not allowed
OFF
Normal operation
Table 36 - SW2 DIP switch functions
* if set to ON before POWER ON or reset. To carry out code reset and total reset operations, follow the
instructions given in the sections on system maintenance and system RESET.