168
Centralising of 500 RANGE modules via CVI50 and two ADBT on ELKRON
control panel/expansion
Centralised turning on/turning off control via CVI50 on control panel/expansion with electrical
outputs
SD542-9006
Turning On
Turning On
Turning Off
Turning Off
If on Control panel
Manual parallel
centralised controls
(optional)
D600V
C1A2
C2
BP
A1
D600V
CVI50
N
L
B V
O
B V
O
Lighting circuit No. 1
Lighting circuit No.
2
PILOT WIRE
230 V 50 Hz
R
B
R12M
M
V
E
B
R12M
M
V
E
U
X
jumper
position
jumper
position
-
+
-V
1
-
+
U
Y
Pushbutton
Pushbutton
RR
BV
CVI50
CONTROL PANEL SW CONFIGURATION
Co
nt
ro
l P
an
el
/E
xp
an
si
on
OUTPUT N.L.
O. PULSED COMM.
{
RR
BV
V
E
= green wir
e
M
= brown wire
V
= purple wir
e
B = white wire
R = red wire
O = orange wire
L
CVI50
enables
the
centralising
of
modules
of
the
500
RANGE
(MTR,
MTT,
MTV,
MTK...)
via
two
indepen
-
dent controls: Turning On and Turning Off
By
using
the
keypad
or
the
Hi-Connect
programming
software,
configure the output as follows
:
- OUTPUT TYPE = OUTPUT N.L.
- CUSTOMIZE = O. PULSED COMM.
With
the
Turning
Off
control,
all
the
lights
already
off
will
light
up
again briefly for 1 second and then go off again.
In certain types of installation, this could be a problem. If this is
the
case,
2000
RANGE
modules
(SD54x-9009
/9010
/9011
/9012) or Radio Modules should be used.
500
RANG
E
500
RANGE
WARNING