The type of command to be combined to the text can be selected in addition to the association procedure illustrated above by pressing
GENERIC key 4.
The possible options are:
Not Used
. The key does not perform any action.
Arm
. The key arms the assigned output.
Disarm
: The key disarms the assigned output.
Silent panic
. The key generates a silent panic type event which will be managed by the control panel.
Panic
. The key generates a panic type event which will be managed by the control panel.
Emergency
. The key generates an emergency type event which will be managed by the control panel.
Fire alarm
. The key generates a fire alarm type event which will be managed by the control panel.
Press
repeatedly to exit from the menu.
9.5
RADIO DEVICES TEST
Check correct operation of the system as a whole after having installed and configured the devices.
One of the main tests to be carried out is the testing of radio devices.
9.5.1
Test
The radio input and output devices are tested together with the wired inputs and outputs. The test result is in common. The radio input
and output devices are identified by means of logical address or name.
Proceed as follows to test the wireless signal level of the various devices:
1) Enter
< Master / Installer code >
, press
and then
.
2) Press
repeatedly until TEST appears.
3) Press
and press
repeatedly until ADVANCED TESTS appears.
4) Press
and press
repeatedly until RADIO DEVICES appears.
5) Press
.
6) Press
and
to select the radio expansion module to test. Press
to confirm.
7) Press
.
8) Energise each detector, e.g. by opening the door or window with magnetic contacts or passing in
front of IR detectors
9) The wireless level will appear in graphic form at the end of the test for each device. Use
and
to scroll the list of devices.
10) Press
repeatedly to exit from the menu.
UT01:MASTER
SYSTEM STATUS
UT01:MASTER
TEST
TEST
ADVANCED TESTS
ADVANCED
RADIO DEVICES
RADIO DEVICES
ER01:ER 01
ER01:ER 01
ARE YOU SURE?
TEST
IN PROGRESS...