Installation/Configuration ER600
13
4.1.3
Assembling ER600 expansion in the MP500/16 control panel
IMPORTANT!
It is advisable to NOT INSTALL the ER600 radio expansion module in the MP500/16 control panel, because the
metallic container of the control panel reduces reception of the radio signals, obstructing control of the radio devices
associated with it.
4.2 INSTALLATION OF THE ER600 RADIO EXPANSION
In addition to inside the control panel, the radio expansion can also be installed freely in a special optional container and for the
CP/EXP wall-mounting.
The expansion has terminals for connecting it to the data BUS and the LEDs that signal the functioning of the electronic board. The
tamper of the container must be connected to the SAB of the expansion.
Figure 3 - ER600 radio expansion
Detail
Terminal /
Detail
Description
A
+
BUS Expansion unit power input via bus
+D
BUS Data transmission/reception
D
─
BUS Expansion unit power input via bus
Tamper
Tamper (microswitch) connection terminals external box
B
Button
Buttons and LEDs for the expansion acquisition
Yellow LED
C
Green LED
Signals operation (for details see the
Programming Manual
)
Slow blinking
= normal operating conditions
Fast blinking
= no communication with control panel for at least 1 minute
Jumper
Jumper for the exclusion of the tamper (jumper inserted = tamper excluded)
D
Green LED
Signalling radio module operation