background image

LBT80945 

DS80IM35-001F 

 

DT15 

 

 

 
 
 
 
 
 

 
 

 

 

 

 

 

   

 

 

MADE IN ITALY 

 

 

 

 

 

 

 

 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
Tavola dei paesi in cui le frequenze del prodotto 
sono  limitate  o  non  ammesse  -

  Countries  in 

which the product frequencies are restricted or 
not  allowed  -  T

ableau des pays  dans  lesquels 

les  fréquences  du  produit  sont  limitées  ou  ne 
pas admises 

 
Elkron  è  un  marchio  commerciale  di  Urmet 
S.p.A.  

Elkron is a trademark of Urmet S.p.A. 

Elkron  est  une  marque  commerciale  de  Urmet 
S.p.A. 

Via Bologna, 188/C – 10154 Torino (TO) Italy 
Tel.+39.0113986711 Fax+39.0113986703 

www.elkron.com

 – 

[email protected]

 

CARATTERISTICHE TECNICHE  

Tensione nominale di alimentazione: ........ 12V   +/- 3V 
Assorbimento a 12 V :  ............................ 8mA nom. 22mA max 
Sensibilità Microonda (MW):  ..................... 0,5÷15m±20% (con trimmer) 
Frequenza: ................................................ 10,525 GHz 
Potenza di emissione (EIRP): .................... 8dBm  
Portata: ...................................................... 15 m  
Copertura MW: .......................................... 90° orizzontale - 36° verticale 
Copertura IR: ............................................. 90°  
Zone sensibili:  ........................................... 18 su 4 piani con creep zone 
Opto Relè di allarme: ................................. 100mA / 24V   
Tamper antimanomissione: ....................... 100 mA / 30V  
Tempo Allarme:  ........................................ 3 sec 
Temperatura di funzionamento: ................. -10°C ÷ +55°C 
Umidita Ambientale:...................................  95% 
MTBF Teorico: ........................................... 120.000 ORE  
Dimensioni (h x l x p): ................................ 107x61,5x43,5 mm 
Peso: ......................................................... 110 g 
Livello Prestazione: ................................... EN50131-2-4. Grado 2, CLASSE II 

ACCESSORI OPZIONALI 

  Snodi  per  IR15  -  DT15  -  DT15AM  (10  pezzi)  ref.  80SP1E00113  /  ref. 

80SP1F00113 

AVVERTENZE 

  Installare  il  sensore  su  superfici  rigide,  prive  di  vibrazioni,  ad  una  altezza 

compresa tra 2 e 2,3 metri facendo riferimento ai diagrammi di rilevazione in 
modo  tale  che  il  sensore  rilevi  spostamenti  trasversali  nella  zona  protetta. 
Evitare il posizionamento del sensore vicino a fonti di calore o alla luce diretta 
del sole. 

  Evitare la riflessione dell’energia elettromagnetica su ampie superfici quali ad 

esempio specchi, pareti metalliche etc. 

  Evitare di puntare il sensore su lampade fluorescenti o comunque di porlo nelle 

immediate vicinanze delle stesse. 

  Evitare che esistano, a causa di mobili, scaffalature, etc. zone cieche nell’area 

protetta  entro  cui  possa  muoversi  l’intruso.  Evitare  la  presenza  di  animali 
nell’area protetta. 

  Nel caso di installazioni ad altezze superiori ai 2,1 metri si consiglia l’utilizzo 

dello snodo opzionale, inclinando il sensore in  modo da adattare al meglio i 
campi di copertura alle effettive necessità. 

INSTALLAZIONE SENZA SNODO 

Per rimuovere il coperchio del sensore togliere la vite di chiusura (se inserita) e 
premere con un cacciavite sul dente di fissaggio, verso l’interno della feritoia. 
Per togliere il circuito stampato allargare uno dei ganci E1-E2 (Fig. 2). 

Attenzione: non toccare con le dita il sensore piroelettrico. 

Fondo plastico del sensore (Fig. 2): 
F1-F4 = PREDISPOSIZIONI PER IL FISSAGGIO AD ANGOLO 
A-B = PREDISPOSIZIONI PER IL FISSAGGIO SU SUPERFICIE PIANA  
C-D = PREDISPOSIZIONI PER IL PASSAGGIO CAVI 
Fissare il fondo plastico alla parete con le viti e i tasselli, avendo cura che le teste 
delle stesse  non  tocchino la  scheda elettronica. Rimontare il circuito sul fondo 
plastico. 

INSTALLAZIONE CON SNODO  

I manuali completi degli snodi sono disponibili sul sito www.elkron.com. 

DESCRIZIONE MORSETTIERA 

I

  

Ingresso Inhibit  

 

 

 

- +  

Alimentazione 12V 

 

  

NC TAMP

   Contatto N.C.  

NC ALL

 

Contatto N.C. del relè di allarme 

PRIMA ALIMENTAZIONE 

Fornita l’alimentazione, il sensore entra nella fase di inizializzazione, durante la 
quale  i  3  LED  lampeggiano  alternativamente.  Dopo  questa  fase  (che  dura  60 
secondi circa), il sensore diventa operativo. 
In  questa  modalità,  indipendentemente  dallo  stato  del  Jumper  di  LED  OFF,  il 
sensore  visualizzerà  le  rilevazioni  della  Microonda,  quelle  dell’Infrarosso  e  lo 
stato di Allarme per permettere all’Installatore di verificarne il funzionamento. 
Questa condizione permane per 20 minuti. 
Trascorso questo tempo il Sensore visualizzerà: 

  se in Led ON ( Jumper inserito) solo gli Allarmi tramite il led Blu; 

  se in Led OFF (Jumper NON inserito) solo eventuali memorie. 

Procedere con il walk test in questo modo: 
MW (Microonda) 

Regolare il trimmer (portata  0,5 - 15 mt) in funzione dell’ambiente da proteggere, 
verificando le rilevazioni di MW tramite il LED VERDE. 

Nota: la portata della MW va regolata al minimo necessario poiché, essendo le 
Microonde in grado di oltrepassare i muri, possono rilevare disturbi e movimenti 
all’esterno del locale da proteggere

INFRAROSSO (PIR) 

Applicare il frontale plastico e, a LED spenti, muoversi nell’area di pertinenza del 
sensore verificando la rilevazione del PIR tramite il LED GIALLO.  

FUNZIONI 

AUTOMATIC ECO 

Il  sensore  è  equipaggiato  con  uno  speciale  algoritmo  che  riduce  al  minimo  le 
emissioni della Microonda. Senza necessariamente collegare l’ingresso di Inhibit, 
il  sensore,  tramite  il  monitoraggio  dei  movimenti  nell’ambiente,  determina  se 
l’impianto  è  inserito  o disinserito.  Questa  cognizione  gli  permette  di limitare  al 
massimo  le  emissioni  di  Microonda  ad  impianto  disinserito  e  quindi  di  non 
irradiare inutilmente le persone presenti nell’ambiente.  
Si  ottiene  questo  vantaggio  pur  senza  avere  nessuna  perdita  di  sensibilità  di 
rilevazione, né di immunità ai falsi allarmi. 
Il jumper disattiva / attiva le visualizzazioni di rilevazione, mantenendo abilitate le 
visualizzazioni relative alle memorie. 

  

 

 
 
 

FUNZIONI CON INGRESSO INHIBIT 

Queste  funzioni  vengono  attivate/disattivate  tramite  inserimento/disinserimento 
dell’impianto. A tale proposito viene considerato: 

  12V sull’ingresso INHIBIT =  impianto disinserito 

  0V sull’ ingresso INHIBIT =  impianto inserito 

ABILITAZIONE REMOTA LED - 

CONDIZIONE RICHIESTA LED OFF

 

Al disinserimento dell’impianto, il sensore si predispone  alla riabilitazione delle 
visualizzazioni  di  rilevazione.  Le  visualizzazioni  verranno  riabilitate  alla  prima 
rilevazione effettuata e rimarranno attive per 30sec. 

MEMORIE

 

Al disinserimento dell’impianto, verrà visualizzata la memoria del primo allarme 
avvenuto,  come  in  TAB.1  (

VISUALIZZAZIONI  IN  STATO  DI  MEMORIA)

.  La 

memoria verrà resettata al successivo inserimento dell’impianto. 

RITARDO della MEMORIA per utilizzo in INGRESSI TEMPORIZZATI  
Tempo di  uscita

: gli allarmi che si verificano  entro i primi 30” dall’inserimento 

dell’impianto vengono cancellati.  

Tempo  di  ingresso

:  gli  allarmi  che  si  verificano  30”  prima  del  disinserimento 

dell’impianto vengono cancellati. 

 
DICHIARAZIONE DI CONFORMITÀ UE SEMPLIFICATA  

Il fabbricante, URMET S.p.A., dichiara che il tipo di apparecchiatura radio: 
RIVELATORE  A  DOPPIA  TECNOLOGIA  DT15  è  conforme  alla  direttiva 
2014/53/UE. Il testo completo della dichiarazione di conformità UE è disponibile 
al seguente indirizzo Internet: 

www.elkron.com

DIRETTIVA 2012/19/UE DEL PARLAMENTO EUROPEO  E DEL CONSIGLIO 
del  4  luglio  2012  sui  rifiuti  di  apparecchiature  elettriche  ed  elettroniche 
(RAEE). 

Il simbolo del cassonetto barrato riportato sull’apparecchiatura o sulla 
sua  confezione indica che il prodotto alla fine della propria vita  utile 
deve essere raccolto separatamente dagli altri rifiuti. L’utente  dovrà, 

pertanto, conferire l’apparecchiatura giunta a fine vita agli idonei centri comunali 
di raccolta  differenziata  dei rifiuti  elettrotecnici  ed  elettronici.  In  alternativa alla 
gestione  autonoma  è  possibile  consegnare  l’apparecchiatura  che  si  desidera 
smaltire al rivenditore, al momento dell’acquisto di una nuova apparecchiatura di 
tipo equivalente. Presso i rivenditori di prodotti elettronici con superficie di vendita 
di almeno 400 m2 è inoltre possibile consegnare gratuitamente, senza obbligo di 
acquisto, i prodotti elettronici da smaltire con dimensione massima inferiore a 25 
cm. L’adeguata raccolta differenziata per l’avvio successivo dell’apparecchiatura 
dismessa  al  riciclaggio,  al  trattamento  e  allo  smaltimento  ambientalmente 
compatibile contribuisce ad evitare possibili effetti negativi sull’ambiente e sulla 
salute  e  favorisce  il  reimpiego  e/o  riciclo  dei  materiali  di  cui  è  composta 
l’apparecchiatura

 

 

TECHNICAL SPECIFICATIONS  

Nominal power voltage: ............................. 12V   +/- 3V 
Consumption at 12 V :

 

 .......................... 8mA nom.

 

22mA max. 

Microwave sensitivity (MW):

 

 .................... 0,5÷15m±20% (with trimmer) 

Frequency: ................................................ 10.525 GHz 
Emission power (EIRP): ............................ 8dBm  
Range: ....................................................... 15 m  
MW coverage: ........................................... 90

 horizontal - 36

 vertical 

IR coverage: .............................................. 90°  
Sensitive zones:

 

 ...................................... 18 on 4 floors with creep zone 

Alarm relay opto: ....................................... 100mA / 24V   
Tamperproof switch: .................................. 100 mA / 30V  
Alarm time:

 

 .............................................. 3 sec 

Working temperature range: ...................... -10

C – +55

Ambient humidity: ......................................  95% 
Theoretical MTBF: ..................................... 120,000 HOURS  
Dimensions (h x w x d): ............................. 107x61.5x43.5 mm 
Weight: ...................................................... 110 g 
Performance level: .................................... EN50131-2-4. Degree 2, CLASS II 

OPTIONAL ACCESSORIES 

  Brackets  for  IR15  -  DT15  -  DT15AM  (10  pcs)  Ref.

 

80SP1E00113  /  Ref. 

80SP1F00113 

CAUTIONS 

  Install  the  sensor  on  rigid,  vibration-free  surfaces  at  a  height  comprised 

between 2 and 2.3 metres making reference to the detection diagrams so that 
the  sensor  can  detect  movements  crossing  the  protected  zone  and  the 
microwave module can detect approaching movements.

 

Avoid positioning the 

sensor close to sources of heat or direct sunlight. 

  Avoid  the  reflection  of  electromagnetic  energy  on  large  surfaces,  such  as 

mirrors, metal walls etc. 

  Avoid pointing the sensor towards, or in all cases placing it near, fluorescent 

lights. 

  Avoid  the  creation  of  blind  areas  caused  by  furniture,  shelving  etc.  in  the 

protected area in which an intruder could move about.

 

Avoid the presence of 

animals in the protected area. 

  In case of installations at heights greater than 2.1 metres, it is advisable to use 

the optional bracket, including the sensor so as to adapt the coverage fields 
better to the actual needs. 

INSTALLATION WITHOUT BRACKET 

To remove the sensor cover, remove the fastening screw (if inserted) and press 
with a screwdriver on the fastening screw towards the inside of the slot. 
Widen one of the hooks E1-E2 to remove the printed circuit (Fig. 2). 

Warning:

 

do not touch the pyroelectric sensor with your fingers. 

Plastic bottom of the sensor (Fig. 2): 
F1-F4 = SET-UP FOR FIXING IN CORNER 
A-B = SET-UP FOR FIXING ON FLAT SURFACE  
C-D = SET-UP FOR CABLE PASSING 
Fix the plastic bottom to the wall with screws and anchor bolts being careful that 
they do not touch the electronic board.

 

Refit the circuit onto the plastic bottom. 

INSTALLATION WITH BRACKET  

The  complete  user  manuals  of  the  brackets  are  available  on  the  website 
www.elkron.com. 

TERMINAL BOARD DESCRIPTION 

I

  

Inhibit

 input

   

 

 

- +  

12V power   

  

NC TAMP

  

NC contact  

NC ALL

 

NC alarm relay contact 

FIRST POWER-ON 

When power is connected, the sensor will start an initialising step during which 
the three LEDs will blink alternatively.

 

The sensor will start working after this step 

(which lasts approximately 60 seconds). 
In this mode, regardless of the state of the LED OFF jumper, the sensor will show 
the microwave detections, the infrared detection and the alarm state to allow the 
installer to check operation. 
This condition will persist for 20 minutes. 
The following will appear on the sensor after this time: 

  in LED ON mode (jumper on) alarms only by means of the blue LED; 

  in LED OFF mode (jumper NOT inserted) memories only. 

Proceed with the walk test, as follows: 
MW (Microwave) 

Set the trimmer (range 0.5 - 15 m) according to the environment to be protected 
and check the MW detections by means of the GREEN LED. 

Note:

 

The MW range must be set to the minimum because microwaves can cross 

walls and detect disturbances and movements outside the room to be protected.

INFRARED (PIR) 

Apply the plastic front and with the LEDs off move in the area of pertinence of the 
sensor checking PIR detection using the YELLOW LED.  

FUNCTIONS 

AUTOMATIC ECO 

The sensor is provided with a special algorithm which reduces to the microwave 
emissions to the minimum. 
Without needing to connect the Inhibit input, the sensor determines whether the 
system is on or off by monitoring the movements in the environment. 
This allows to limit microwave emissions to the minimum when the system is off 
and to avoid unnecessary radiations for the people present in the environment. 
This  advantage  is  achieved  without  losing  detection  sensitivity  or  false  alarm 
immunity. The jumper deactivates / activates the detection displays, keeping the 
displays relating to the memories enabled. 
 

  

 

 
 
 

FUNCTIONS WITH INHIBIT INPUT 

These functions  are  activated/deactivated by  switching  the  system  on  and  off.

 

With this regard: 

  12V on the INHIBIT input = system off 

  0V on the INHIBIT input =  system on 

REMOTE LED ENABLING - 

LED OFF REQUIRED CONDITION

 

The sensor is set to re-enable detected views when the system is switched off.

 

The views will be re-enabled at the first detection and will remain active for 30sec. 

MEMORIES

 

The memory of the first alarm will be viewed when the system is switched off as 
shown in TAB. 1 (

MEMORY STATE VIEWS)

.

 

The memory will be reset when 

the system is switched on again. 

MEMORY DELAY FOR TIMED ENTRANCE  
Exit  time

:

 

the  alarms  occurring  during  the  first  30"  from  when  the  system  is 

switched on are deleted.  

Entrance time

:

 

the alarms occurring during the 30" before the system is switched 

off are deleted. 

 

 
SIMPLIFIED EU DECLARATION OF CONFORMITY  

Hereby,  URMET  S.p.A.  declares  that  the  radio  equipment  type:  DUAL 
TECHNOLOGY DETECTOR DT15 is in compliance with Directive 2014/53/EU. 
The  full  text  of  the  EU  declaration  of  conformity  is  available  at  the  following 
internet address: 

www.elkron.com

 

DIRECTIVE 2012/19/EU OF THE EUROPEAN PARLIAMENT AND OF 
THE  COUNCIL  of  4  July  2012  on  waste  electrical  and  electronic 
equipment (WEEE). 

The symbol of the crossed-out wheeled bin on the product or on its 

packaging indicates that this product must not be disposed of with your other 
household waste. 
Instead, it is your responsibility to dispose of your waste equipment by handing 
it over to a designated collection point for the recycling of waste electrical and 
electronic equipment. The separate collection and recycling of your waste 
equipment at the time of disposal will help to conserve natural resources and 
ensure that it is recycled in a manner that protects human health and the 
environment.

 

For more information about where you can drop off your waste equipment for 
recycling, please contact your local city office, your household waste disposal 
service or the shop where you purchased the product.

 

 
 

CARACTERISTIQUES TECHNIQUES 

 

Tension nominale d’alimentation :.............. 12V   +/- 3V

 

Absorption à 12 V  :  ................................ 8mA nom. 22mA maximum

 

Sensibilité micro-onde (MW) :  ................... 0,5÷15m±20% (par  

commutateur)

 

Fréquence : ................................................ 10,525 GHz 
Puissance d'émission (EIRP) : ................... 8dBm 

 

Portée : ...................................................... 15 m 

 

Couverture MW : ........................................ 90° horizontale - 36° verticale

 

Couverture IR :........................................... 90° 

 

Zones de détection :  ................................. 18 faisceaux/4 plans creep 

zone

 

Relais d'alarme : ........................................ 100mA / 24V  

 

Pouvoir tamper anti-ouverture :.................. 100 mA / 30V

 

Temps de maintien en alarme ................... 3 s

 

Température de fonctionnement : .............. -10

 ÷ +55

 

Humidité relative admissible : ....................  95%

 

MTBF théorique : ....................................... 120.000 heures 

 

Dimensions (h x l x p) ................................ 107x61,5x43,5 mm

 

Poids : ........................................................ 110 g 
Niveau de performances : .......................... EN50131-2-4, Degré 2, 

CLASSE II

 

ACCESSOIRES EN OPTION 

  Rotules pour IR15 - DT15 - DT15AM (10 pcs.) Réf. 80SP1E00113 / Réf. 

80SP1F00113 

INSTRUCTIONS 

  Installer  le  détecteur  sur  des  surfaces  rigides,  non  exposées  aux 

vibrations,  à  une  hauteur  comprise  entre  2  et  2,2  m  en  fonction  des 
diagrammes  typiques  de  détection,  de  manière  à  ce  que  le  détecteur 
détecte les déplacements qui croisent la zone protégée et que le module 
micro-onde  détecte  les  mouvements  en  approche.  Eviter  de  placer  le 
détecteur à proximité de sources de chaleur ou de l’exposer à la lumière 
directe du soleil. 

  Eviter le réfléchissement de l'énergie électromagnétique sur de grandes 

surfaces (par exemple, miroirs, parois métalliques, etc.). 

  Eviter  de  pointer  le  détecteur  sur  des  lampes  fluorescentes  ou  de  le 

placer à proximité de celles-ci. 

  Eviter de créer, du fait de meubles, d’étagères, etc., des zones invisibles 

à  l'intérieur  de  l’espace  protégé,  qui  permettraient  à  un  intrus  de  se 
déplacer. Eviter la présence d'animaux dans la zone protégée. 

  En cas d’installations à des hauteurs supérieures à 2,1 m, il est conseillé 

d'utiliser  la  rotule  optionnelle,  en  inclinant  le  détecteur  de  manière  à 
adapter au mieux les champs de couverture aux nécessités effectives. 

INSTALLATION SANS ROTULE 

Pour déposer le capot du détecteur, ôter la vis de fermeture (si présente) et 
appuyer sur l’ergot de fixation. Pour enlever le circuit imprimé, élargir l’une 
des attaches E1-E2 (Fig. 2). 

Attention : ne pas toucher le détecteur pyro-

électrique avec les doigts

 

Fond en plastique du détecteur (Fig. 2) : 
F1-F4 = PRE-PERÇAGE POUR LA FIXATION ANGULAIRE 
A-B = PRE-PERÇAGE POUR LA FIXATION SUR SURFACE PLANE  
C-D = PRE-PERÇAGE POUR LE PASSAGE DES CABLES 
Fixer le  fond  en  plastique  à la  paroi  à  l’aide  des  vis  et  des  chevilles,  en 
veillant  à  ce  que  leurs  têtes  ne  soient  pas  en  contact  avec  la  carte 
électronique. Reposer le circuit sur le fond en plastique.

 

INSTALLATION AVEC ROTULE 

 

Les manuels d'utilisation complets des rotules sont disponibles sur le site 

www.elkron.com

DESCRIPTION BOITE A BORNES 

I

  

Entrée Inhibit  

 

 

 

- +  

Alimentation 12V 

 

  

NC TAMP

   Contact N.F. 

 

NC ALL

 

Contact N.F. du relais d'alarme

 

PREMIERE ALIMENTATION 

Une fois alimenté, le détecteur entre dans la phase d'initialisation, au cours 
de  laquelle  les  trois  LED  clignotent,  puis restent  allumées.    Au  terme  de 
cette  phase  (d’une  durée  d’environ  60  secondes),  le  détecteur  est 
opérationnel.  Dans  cette  modalité, indépendamment  de  l’état  du  cavalier 
LED OFF, le détecteur affichera les détections de la micro-onde, celles de 
l’infrarouge  et  l’état  d’Alarme  pour  permettre  à  l’installateur  de  vérifier  le 
fonctionnement. Cette condition perdure pendant 20 minutes. Au bout de c 
délai, le détecteur affichera : 

  si LED ON (cavalier en place), uniquement les alarmes via la LED 

bleue ; 

  Si  LED  OFF  (cavalier  NON  en  place),  uniquement  d’éventuelles 

mémoires. 

Pour le test de portée, procéder comme suit : 
MW (Micro-onde) 

Régler le trimmer (portée  0,5 - 15 mt) en fonction de la zone à protéger, en 
vérifiant les détections de MW à travers la LED VERTE. 

Note : la portée MW doit être réglée sur la valeur minimum nécessaire ; en 
effet, les micro-ondes étant en mesure de passer à travers les murs, elles 
peuvent  détecter  des  perturbations  ou  des  mouvements  à  l’extérieur  du 
local à protéger.

 

INFRAROUGE (PIR) 

Appliquer la façade en plastique et, LED éteintes, se déplacer dans la zone 
concernée, en vérifiant la détection du PIR à travers la LED JAUNE. 

 

FONCTIONS 

AUTOMATIC ECO 

Le détecteur est doté d’un algorithme spécial qui minimise les émissions de 
la Micro-onde. Sans nécessairement raccorder l’entrée Inhibit, le détecteur, 
à  travers  le  monitorage  des  mouvements  dans  l’espace,  détermine  si 
l’installation est sous/hors tension. Cette condition lui permet de limiter au 
maximum  les  émissions  de  Micro-onde  lorsque  l’installation  est  hors 
tension, pour ne pas irradier inutilement les personnes présentes dans la 
zone  concernée.  Cet  avantage  n’est  pas  obtenu  au  détriment  de  la 
sensibilité  de  détection  ou  de l’immunité  aux  fausses  alertes. Le  cavalier 
désactive  /  active  les  affichages  de  détection,  en  gardant  activés  les 
affichages relatifs aux mémoires. 
 

 

 

 

 

FONCTIONS AVEC ENTREE INHIBIT 

Ces fonctions sont activées/désactivées à travers la mise sous/hors tension 
de l’installation. A ce propos, l‘on considère :

 

  12V sur l’entrée INHIBIT =  installation hors tension 

  0V sur l’entrée INHIBIT =  installation sous tension 

HABILITATION LED A DISTANCE - 

CONDITION REQUISE : LED OFF

 

Lors de la mise hors tension de l’installation, le détecteur se prépare pour 
le rétablissement des signalisations de détection. Les signalisations seront 
rétablies dès la première détection effectuée et elles demeureront actives 
pendant 30 s.

 

MEMOIRES

 

Lors  de  la  mise  hors  tension  de l’installation,  la  mémoire  de  la  première 
alarme  intervenue  sera  affichée,  comme  indiqué  dans  le    TAB.1 
(

AFFICHAGES D’ETAT MEMOIRE)

. La mémoire sera réinitialisée lors de 

la mise sous tension successive de l’installation.

 

DELAI 

DE 

MEMOIRE 

POUR 

L’UTILISATION 

D’ENTREES 

TEMPORISEES 

 

Temps de sortie :

 les alarmes qui surviennent au cours des 30 premières 

secondes après l’activation de l’installation, sont effacées. 

 

Temps  d’entrée :

  les  alarmes  qui  surviennent  30  secondes  avant  la 

désactivation de l’installation, sont effacées.

 

 
DECLARATION UE DE CONFORMITE SIMPLIFIEE  

Le soussigné, URMET S.p.A., déclare que l’équipement radioélectrique du 
type  DÉTECTEUR  À  DOUBLE  TECHNOLOGIE  DT15  est  conforme  à  la 
directive 2014/53/UE. Le texte complet de la déclaration UE de conformité 
est disponible à l’adresse internet suivante: 

www.elkron.com

LES  BONS  GESTES  DE  MISE  AU  REBUT DE  CE  PRODUIT

 

(Déchets 

d’équipements électriques et électroniques) 

Ce  symbole  apposé  sur  le  produit,  ses  accessoires  ou  sa 
documentation  indique  que  ni  le  produit,  ni  ses  accessoires 
électroniques  usagés  (chargeur,  casque  audio,  câble  USB, 
etc.), ne peuvent être jetés avec les autres déchets ménagers. 
La  mise  au  rebut  incontrôlée  des  déchets  présentant  des 

risques  environnementaux  et  de  santé  publique,  veuillez  séparer  vos 
produits et accessoires usagés des autres déchets. Vous favoriserez ainsi 
le  recyclage  de  la  matière  qui  les  compose  dans  le  cadre  d’un 
développement durable. 

RUS  

SVK 

UK 

TAB. 1 

VISUALIZZAZIONI IN STATO DI MEMORIA 

ALLARME 

VERDE 

BLU 

GIALLO 

PIR+MW 

SPENTO 

ACCESO 

SPENTO

 

TAB. 1 

MEMORY STATE VIEWS 

ALARM 

GREEN 

BLUE 

YELLOW 

PIR+MW 

OFF 

ON 

OFF

 

TAB. 1

 

AFFICHAGES D’ETAT MEMOIRE 

ALARME 

VERT 

BLEU 

JAUNE 

PIR+MW 

ETEINT 

ALLUME 

ETEINT

 

RIVELATORE A DOPPIA 
TECNOLOGIA  

DUAL TECHNOLOGY 
DETECTOR  

DÉTECTEUR À DOUBLE 
TECHNOLOGIE 

 

 

C

O

PE

R

TU

R

 

C

O

VE

R

 

C

O

U

VE

R

TU

R

GB 

FR 

JU

M

PE

R

 

LE

D

 P

IR

 

LE

D

 A

LL

LE

D

 M

W

 

MW

 

TR

IM

M

ER

 

PIR

 

LED ON 

 

Spostando il 
Jumper a destra 
o rimuovendolo 
si seleziona  
LED ON.  

 

LED OFF

 

Spostando il 
Jumper a sinistra 
si seleziona  
LED OFF.  

 

LED ON 

 

Moving the 
Jumper to the 
right or removing 
it, it is selected 
LED ON.  

 

LED OFF

 

Moving the 
Jumper to the left 
it is selected LED 
OFF.  

 

LED ON 

 

Déplacer le 
cavalier vers la 
droite ou le 
supprimer pour 
sélectionner LED 
ON.  

 

LED OFF

 

Déplacer le 
cavalier vers la 
gauche pour 
sélectionner LED 
OFF.  

 

Отзывы: