background image

ERPB2-8C, ERPB2-8RAC, ERPBV2-8C, ERPBV2-8RAC, LRPB2-8C, LRPB2-8RAC

97924C  (Rev. A - 03/03)

Page 1

SWIRLFLO   Refrigerated fountains with FLEXI-GUARD

INSTALLATION, CARE & USE MANUAL

T M

T M

!

CAUTION:

Review these instructions before beginning installation. Be sure that installation
conforms to all plumbing, electrical and other applicable codes.

!

WARNING:

When installation is complete, ensure these instructions are left in the plastic bag
provided inside the installed unit for future reference.

!

WARNING:

Service to be performed by authorized service personnel only.

INSTALLER

NOTE: It is common practice to ground electrical hardware such as telephones, computers and other devices

to available water lines. This can, however, cause electrical feedback in the plumbing circuit, which

results in an “electrolysis” effect occurring in the fountain. This may result in water which has a metallic

taste to it or has a noticeable increase in the metallic content of the water.

When inspecting plumbing circuit, remember the line may be grounded some distance from the

installation, and may occur outside the building or area in which the unit is being installed.

This condition can be avoided (in most cases) by using recommended materials during installation. Any

drain fittings provided by the installer should be made of 

plastic

 which will 

electronically isolate

 the

fountain from the remainder of the building’s plumbing circuits.

      ERPB2-8C                                                     ERPB2-8RAC

Содержание SWIRFLO ERPB2-8C

Страница 1: ...dware such as telephones computers and other devices to available water lines This can however cause electrical feedback in the plumbing circuit which results in an electrolysis effect occurring in the fountain This may result in water which has a metallic taste to it or has a noticeable increase in the metallic content of the water When inspecting plumbing circuit remember the line may be grounde...

Страница 2: ...8RAC ERPBV2 8C ERPBV2 8RAC LRPB2 8C LRPB2 8RAC Page 2 LEGEND A 1 4 O D Tube Water Outlet Connection B 3 8 O D Tube Water Inlet Connection C 1 1 4 Waste Tube D ELECTRICAL INLET Figure 1 Rough in Dimensions Model LRPB2 8C Model LRPB2 8RAC ...

Страница 3: ...iller by pushing it until it reaches a positive stop approximately 3 4 19mm on the marked chiller inlet port Connect building supply line to strainer See Figure 3 Caution DO NOT SOLDER tubes inserted into the strainer as damage to o rings may result 4 LRPB Models Mount filter head assembly to side of chiller See Figure 4 Make connections between filter and building supply line 3 8 O D tube not por...

Страница 4: ...a 1 4 x 1 4 tee provided on the marked chiller outlet port Insert the 1 4 poly tubing coming from the fountain into the union CAUTION DO NOT SOLDER tubes inserted into the strainer as damage to o rings may result 9 These products are designed to operate on 20 105 PSIG supply line pressure If inlet pressure is above 105 PSIG a pressure regulator must be installed in the supply line CAUTION Any dama...

Страница 5: ...RAC 97924C Rev A 03 03 BUBBLERDETAIL VANDALRESISTANT BUBBLER DETAIL NOTE When installing replacement bubbler and pedestal tighten nut Item 7 only to hold parts snug in position Do Not Overtighten Basin Figure 8 Bubbler Details 1 2 3 4 5 6 7 8 9 10 Basin Page 5 ...

Страница 6: ... 3 5 Figure 9 Filter Assembly Water Sentry Filter Detail DESCRIPTION 1 2 3 4 5 6 7 ITEMNO PARTNO 51294C 70792C 70823C 70822C 51299C 70818C 22490C Filter Head Assy Screw 8 18 x 75 PH Fitting Superseal 3 8 10 mm Fitting Superseal 3 8 6 mm Filter Assy Elbow 3 8 10mm Bracket WATER SENTRY FILTER PARTS LIST See Fig 9 ...

Страница 7: ...8RAC ERPBV2 8C ERPBV2 8RAC LRPB2 8C LRPB2 8RAC 97924C Rev A 03 03 Page 7 Figure 10 Fountain Body Assembly Figure 11 Push Button Assembly 15 16 17 18 19 20 33 34 23 38 See Fig 8 11 21 See Fig 8 12 24 31 13 22 29 14 34 ...

Страница 8: ...bbler VR Gasket Black 68 x 1 03 VR Nipple Bubbler VR Basin Swirlflow Lower Shell Fountain Body Cover Plate Sleeve Pin Push Button Push Button Holder Regulator Regulator Retaining Nut Gasket Drain Assy Drain Tailpipe Assy Strainer Ferrule Poly Tubing Cut To Length Tee 1 4 Strainer Provided with Chiller Back Panel RH ADA Back Panel LH ADA Lower Panel Screw 10 24 x 62 HHSM Screw 8 32 x 38 THSM Screw ...

Отзывы: