2000000556 (Rev. B - 06/22)

HAC8BLWFN_2A

Combination Refrigerated Drinking Fountain (Cooler) and Bottle Filling Station delivers chilled, clean potable drinking water. Top Bottle  

Filling section offer touchless activation to dispense water for bottles. While the bottom Water Cooler section, which houses the refrigeration and         

filtration systems, delivers a steady stream of water for direct drinking at the press of front and sidebars.

•  Electrical: 220-240 Vac, 50/60 Hz, (See Nameplate for Amperage), 

1 phase

•  Ambient Air Temperature: 50-89.6 °F (10-32 °C)
• 

Water Pressure: 20-105 psig (0.14-0.72 MPa)

• 

Maximum Water Temperature: 90 °F (32 °C)

• 

Sound Pressure level (A-weighted): < 70 dBA

•  Refrigerant: R290
•  Ingress Protection: IP20
• 

For Indoor Commercial Use only

• 

Water Inlet: 3/8”O.D. unplated copper tube

• 

Waste Water Outlet: 1-1/4” O.D. tube

DANGER

 

– Indicates death or serious injury will result if proper precautions are not taken.

WARNING

 – Indicates death, serious injury or property damage can result if proper precautions are not taken.

CAUTION

 – Indicates some injury or property damage may result if proper precautions are not taken.

Definitions

Authorized Service Personnel

 – Factory trained personnel or personnel having working knowledge of electrical, plumbing and 

machine (appliance) maintenance procedures. Service personnel must have specialized training for flammable refrigerants.

Safety

DANGER

• 

Please read these instructions completely before starting the installation or performing any service. Failure to follow the instructions                                       

and safety precautions in this manual can result in serious injury or death.

•  After installation, keep these instructions in a safe location for future reference.
• 

Electric supply must be identical in voltage, cycle, and phase to that specified on nameplate.

• 

Electrical supply may require Ground Fault Circuit Interrupter (GFCI) protection. Consult specific application and local codes. 

• 

A means for disconnecting electrical supply to the unit must be incorporated in the fixed wiring in accordance with wiring rules. This is to 

allow electrical disconnection of the unit from electrical supply after installation.

WARNING

Description

Ratings

Notice: 

Coolers that use flammable refrigerants, such as R-600a (isobutane), R-290 (propane) will be marked with a 

 

specific symbol that notifies the servicer of the presence of these refrigerants. A service provider should review this marking 

and follow all instructions from the original equipment manufacturer.

•  Keep clear of obstructing all ventilation openings in the appliance enclosure or in the structure for building-in.
•  Place in a well ventilated area to prevent accumulation of refrigerant.
• 

No open flame or sparks during service or repair.

• 

For use with clean, clear potable drinking water only. Do not use with water that is microbiologically unsafe or of unknown quality without 

adequate disinfection before the system.

•  Installation and connection to water and electrical mains must be in compliance with local and national laws. 
• 

All Installation and Service work must be performed by trained / authorized service personnel. 

Original Instructions

Hydroboost

®

 Bottle Filling Station and Cooler

Installation / Care / Use Manual

Содержание Hydroboost HTHBHAC8BLSSWF25N

Страница 1: ...o follow the instructions and safety precautions in this manual can result in serious injury or death After installation keep these instructions in a safe location for future reference Electric supply...

Страница 2: ...rap Remove the slip nut and gasket from the trap and install them on the cooler waste line making sure that the end of the waste line fits into the trap Assemble the slip nut and gasket to the trap an...

Страница 3: ...Filler Mounting 1 Remove two 2 mounting screws with 5 32 4mm Allen wrench holding top cover to Bottle Filler see Fig 3 Remove top cover Note Do not discard mounting screws they will be needed to reins...

Страница 4: ...aks found corrected plug Bottle Filler and unit into wall Be sure to reinstall fuse to the circuit or switch the circuit breaker back to the ON position 15 Once power is applied to Bottle Filler the G...

Страница 5: ...14 14 COOLER BACK HANGER BRACKET Figure 9 CORRECT STREAM HEIGHT Figure 10 Water Valve Mechanism ADJUSTMENT PROCEDURE Turn adjustment screw Counter Clockwise until water flow from bubbler starts Turn a...

Страница 6: ...lt back to bottle count and be back in run mode 2 When the display changes to SETTINGS depress the button again The display will change to show RNG SET Range set for IR sensor UNIT TYP Type of unit RE...

Страница 7: ...ng Kit Fan Motor Assy Blade Motor Shroud Screws Nut Kit Hardware Kit Bubbler Nipple Gasket Kit Condenser Drier Kit Compr Mtg Hdwe Grommets Clips Studs Kit Heat Exchanger Drier Kit Bottle Filler Drain...

Страница 8: ...y Manufacturing Co 1333 Butterfield Road Suite Downers Grove IL 60515 U S A 630 574 8484 www elkay com Uses R290 refrigerant 3 5 18 25 4A 15 6 18 27 37 21 4B 18 36 28 18 26 20 17 8 7 See Fig 2 for Pus...

Отзывы: