background image

Page 5

  98980C  (REV. K - 08/17)    

LVRCDWS*A, *2A   LVRCTLDDWSC*A, *2A   LVRC8WS*1A, *2A, *3A   LVRCTL8WSC*1A, *2A, *3A

Fig. 4

 

Note:  Screw the locknut hand tight to seal

Fig. 5

BOTTLE  FILLER  INSTALLATION

1)   

Remove wall mounting plate(s)

 from Cooler(s). Install Wall Mounting Plate(s) as per rough-in diagrams on sheet 2 or 3 of this instruction.

      

NOTE:

 Mounting plate(s) 

MUST

 be supported securely. Add fixture support carrier if wall will not provide adequate support. 

2)   

For Single Model Installations:

 Install water cooler onto wall bracket and secure to wall. Connect drain and water inlet to cooler as required (See rough- 

      in on page 2). 

DO NOT

 connect power to cooler at this time or turn water supply on.

2a) 

 For Two Level Model Installations:

 Install lower water cooler only at this time onto bracket as per rough-in diagram on  sheet 3.

3)   

Remove VRC Bottle Filler

 from carton. Remove 3/8” to 1/4” reducing union from end of waterline, (do not throw away it will be needed later). Lay Bottle Filler 

      on water cooler basin and cut insulation from tube even with bottom of unit, remove this insulation from the 3/8” tube, but do not discard.  Feed the power 

      cord, and waterline through the hole on top of water cooler. Feed the Reset Button wire from circuit board down through the hole in the basin.  

      

NOTE:

 To prevent scratching the basin place a towel or soft cloth over the entire basin when working above it.

4)   

With the power cord,

 waterline and reset button wires through the hole on top of water cooler place Bottle Filler on to mounting bracket on basin.

      (See Fig. 3). Make sure bottle filler is installed properly on the basin gasket.

5)   

Once Bottle Filler

 is installed on basin mounting bracket, tighten the two screws (supplied) one on each side of the bottle filler.  Install Top Cover on Bottle 

      Filler (See FIG. 3) with two mounting screws (supplied) . Caution do not over tighten screws.

6)   

For Two Level Model Installations:

 Secure non-refrigerated unit to wall, connect drains and water inlet. Connect black reset button wires from 

      non-refrigerated unit to the black wires on the refrigerated unit (see step 4).

7)   

For Single Model Installations:

 Install remaining tube insulation to the water line from bottle filler, connect Bottle Filler waterline inside of the water cooler

      by connecting the 3/8” water line with the 3/8” to 1/4” union and short piece of poly tube that was previously installed to the tee at the evaporator outlet. 

7a) 

For Two Level Model Installations: 

Install the 1/4” poly tubing and insulation from the outlet of the filter to the union on top of the evaporator. Install the 

      1/4” poly tubing and insulation from the regulator in the non-refrigerated cooler to one of the tees at the evaporator outlet. Install remaining tube insulation  

      to the water line from bottle filler, connect Bottle Filler waterline inside of the water cooler by connecting the 3/8” water line with the 3/8” to 1/4” union and

      short piece of poly tube that was previously installed to the tee at the evaporator of the refrigerated cooler.

8)   

Install filter cartridge,

 remove filter from carton, remove protective cap, attach filter to filter head by firmly inserting into head and rotating filter clockwise.

       

NOTE: 

If existing plumbing rough-in locations (Drain, Water In, Electric Supply) do not allow the filter to be mounted inside the cooler cabinet 

       the filter can be installed horizontally below the unit.  A retrofit kit is available to mount the filter beneath the cooler.

9)   

Turn water supply on

 and inspect for leaks. Fix all leaks before continuing.

10)  

Once unit has been inspected

 for leaks and any leaks found corrected, plug Bottle Filler and LVRC unit into wall. Be sure to reinstall fuse to the circuit 

       or switch the circuit breaker back to the “ON” position.

11)  

Once power is applied to Bottle Filler,

 the GREEN LED light should illuminate showing good filter status along with the LCD Bottle Counter.

12)  

Verify proper dispensing

 by depressing the button at the top of the Bottle Filler and verify water dispenses.  Note: the first initial dispenses   

       might have air in line which may cause a sputter.  This will be eliminated once all air is purged from the line.

14)  

Once unit tests out

, install Lower Panel back on LVRC water cooler(s).  Unit is now ready for use.

MOUNTING BRACKET

FOR  FASTENING UNIT

TO WALL

TOP COVER

MOUNTING 

SCREWS

Fig. 3

MOUNTING SCREWS

DO NOT REMOVE

MOUNTING SCREWS

DO NOT REMOVE

BOTTLE FILLER

WATER COOLER

NOTE: TRIM PLATES MUST 

BE INSTALLED ON THE 

INSIDE OF THE BOTTLE 

FILLER SIDE PANEL SLOTS.

B

C

A

SIMPLY PUSH IN

TUBE TO ATTACH

TUBE IS SECURED

IN POSITION

PUSH IN COLLET

TO RELEASE TUBE

OPERATION OF QUICK CONNECT FITTINGS

PUSHING TUBE IN BEFORE

PULLING IT OUT HELPS TO

RELEASE TUBE

OPERATION OF QUICK CONNECT FITTINGS

SIMPLY PUSH IN

TUBE TO ATTACH

TUBE IS SECURED 

IN POSITION

PUSH IN COLLET

TO RELEASE TUBE

PUSHING TUBE IN BEFORE 

PULLING IT OUT HELPS TO 

RELEASE TUBE

A

B

C

Содержание GreenSpec LVRC8WS

Страница 1: ...LVRCTL8WSC 1A 2A 3A LVRC8WS LVRC8WSJO LVRCTL8WS LVRCTL8WSJO Factory Prep ezH2O Bottle Filling Station and Cooler INSTALLATION and USE MANUAL IMPORTANT THIS IS AN INDOOR APPLICATION ONLY ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON Model LVRCTL8WS Model LVRC8WS ...

Страница 2: ...N THE BUILDING OR MAY OCCUR AWAY FROM THE BUILDING THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM ...

Страница 3: ...mm 5 1 8 131mm 48 1219mm O 5 16 8mm MOUNTING HOLES 3 PL 1 4 X 1 2 6mm X 13mm OBROUND HOLE 5 PL HANGER BRACKET 7 178mm 7 178mm 16 5 16 414mm 1 1 4 32mm 1 1 4 32mm Single Rough In Fig 1 LVRC8WS REDUCE HEIGHT BY 3 FOR INSTALLATION OF CHILDREN S ADA COOLER LEGEND A RECOMMENDED WATER SUPPLY LOCATION 3 8 O D UNPLATED COPPER TUBE CONNECT STUB 1 1 2 38mm OUT FROM WALL SHUT OFF VALVE NOT FURNISHED B RECOMM...

Страница 4: ...298mm 31 15 16 811mm RIM HEIGHT 8 203mm 18 1 16 459mm 7 178mm 7 178mm 1 1 4 32mm 1 1 4 32mm 16 5 16 414mm O 5 16 8mm HOLES 3 PL 5 3 4 146mm 5 3 4 146mm 1 3 8 35mm 1 3 8 35mm 18 1 2 470mm 3 1 2 89mm 4 1 2 114mm 6 1 4 159mm Single Rough In Fig 1 LVRCTL8WS REDUCE HEIGHT BY 3 FOR INSTALLATION OF CHILDREN S ADA COOLER LEGEND A RECOMMENDED WATER SUPPLY LOCATION 3 8 O D UNPLATED COPPER TUBE CONNECT STUB ...

Страница 5: ... was previously installed to the tee at the evaporator outlet 7a For Two Level Model Installations Install the 1 4 poly tubing and insulation from the outlet of the filter to the union on top of the evaporator Install the 1 4 poly tubing and insulation from the regulator in the non refrigerated cooler to one of the tees at the evaporator outlet Install remaining tube insulation to the water line f...

Страница 6: ...s from the sides of the Bottle Filler Remove the two 2 Pinned Torx Head Screws from the Top Cover remove the Top Cover The Bottle Filler may then be lifted up and off the Water Cooler The water line and Remote Reset Button Wires will still be connected from the Water Cooler to the Bottle Filler 3 For Two Level Model Installations Loosen but DO NOT remove the Pinned Torx Head Screw from the outer s...

Страница 7: ...ount and be back in run mode 2 When the display changes to SETTINGS depress the button again The display will change to show RNG SET Range set for IR sensor UNIT TYP Type of unit REFRIG or NON REFRIG RST BCNT Reset bottle count 3 When display shows UNIT TYPE push program button once the display will show current value Can be REFRIG or NON REFRIG 4 Push button once to change value Once value is sel...

Страница 8: ... again the display will scroll through the two messages above for three cycles and then default back to bottle count and be back in run mode Continued from below 2 When the display changes to SETTINGS depress the button again The display will change to show RNG SET Range set for IR sensor UNIT TYP Type of unit REFRIG or NON RFRG FLT SIZE Select filter capacity RST BCNT Reset bottle count 3 When di...

Страница 9: ...ment Kit Hardware Waterway Parts Kit Retro Filter Mounting Kit Electrical Package 220V Kit Solenoid Valve Replacement 220V Kit Filter Mounting Cover Kit Drain Pad Kit Button Assembly Kit Top Cover Replacement Kit Gasket VR BF Tower Basin Kit Reset Switch Kit Micro Switch REPLACEMENT PART KITS PART NO DESCRIPTION 1 2 3 ITEM NO PART NO 51300C_12PK 98926C 000000746 Filter Assy 3000 Gallon 12 Pack Kit...

Отзывы: