background image

Page 1

1000004299  (Rev. B - 04/2018)

LVRC8WS_2AWR, LVRCWS_2AWR

Combination Vandal Resistant Refrigerated Drinking Fountain (Cooler) and Bottle Filling Station delivers chilled, clean potable drinking water. 

Top Bottle Filling section dispenses water for bottles at the press of the top button. While the bottom Water Cooler section, which houses the 

refrigeration and filtration systems, delivers a steady stream of water for direct drinking at the press of the front button.

•  Electrical: 220Vac, 50Hz, (See nameplate for Amperage), 1 phase.
•  Ambient Air Temperature: 50-100.4°F (10-38°C).
•  Water Pressure: 20-100 psig (0.14-0.69 MPa).
•  Maximum Water Temperature: 90 °F (32 °C).
•  Refrigerant: HFC-R134a

•  Ingress Protection: IP21
• 

For Indoor Commercial Use only.

•  Water Inlet: 3/8”O.D. unplated copper tube.
•  Waste Water Outlet: 1-1/4” O.D. tube

DANGER

 – Indicates death or serious injury will result if proper precautions are not taken.

WARNING

 – Indicates death, serious injury or property damage can result if proper precautions are not taken.

CAUTION

 – Indicates some injury or property damage may result if proper precautions are not taken.

Definitions

Authorized Service Personnel

 – Factory trained personnel or personnel having working knowledge of electrical, 

plumbing and machine (appliance) maintenance procedures.

Safety

DANGER

• 

Please read these instructions completely before starting the installation or performing any service. Failure to follow the instructions and safety 

precautions in this manual can result in serious injury or death.

•   After installation, keep these instructions in a safe location for future reference.
• 

Electric supply must be identical in voltage, cycle, and phase to that specified on nameplate.

• 

Electrical supply must have Ground Fault Circuit Interrupter (GFCI) protection. 

• 

 A means for disconnecting electrical supply to the unit must be incorporated in the fixed wiring in accordance with wiring rules. This is to allow 

electrical disconnection of the unit from electrical supply after installation.

WARNING

• 

For use with clean, clear potable drinking water only. Do not use with water that is microbiologically unsafe or of unknown quality without        

adequate disinfection before the system.

•  Installation and connection to water and electrical mains must be in compliance with local and national laws. 
• 

All Installation and Service work must be performed by an authorized service personnel.

CAUTION

• 

This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory, or mental capabilities 

or lack of experience and knowledge if they have been given supervision or instructions concerning use of the appliance in a safe way and                

understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children 

without supervision.

• 

To prevent a metallic taste or increased metal content in the water due to an electrolysis process caused by electrical feedback from the 

grounding of electrical equipment to water supply and water waste mains, connect to these mains using non-conductive materials. The          

provided filter meets this requirement.

            

Ratings

Description

Installation & Use Manual

Original Instructions

Model: LVRC8WS2KWR ezH2O

®

 Bottle Filling Station and Cooler

Содержание ezH2O LVRC8WS2KWR

Страница 1: ...ep these instructions in a safe location for future reference Electric supply must be identical in voltage cycle and phase to that specified on nameplate Electrical supply must have Ground Fault Circu...

Страница 2: ...o wall bracket and secure to wall Installation Water Line connection 1 Ensure Mains Water Supply has Water Shut off Valve with 3 8 9 5mm compression outlet 2 Connect loose end of supplied 3 8 9 5mm un...

Страница 3: ...MOUNTING HOLES 3 PL 1 4 X 1 2 6mm X 13mm OBROUND HOLE 5 PL HANGER BRACKET 7 178mm 7 178mm 16 5 16 414mm 1 1 4 32mm 1 1 4 32mm HTHBHVR8 25WR ROUGH IN REDUCE HEIGHT BY 3 FOR INSTALLATION OF CHILDREN S A...

Страница 4: ...ugh the hole on top of water cooler place Bottle Filler on to mounting bracket on basin NOTE Make sure bottle filler is installed properly on the basin gasket 6 Once Bottle Filler is installed on basi...

Страница 5: ...ue Can be REFRIG or NON RFRG Push button once to change value Once value is selected the display will show the new value Can be REFRIG or NON RFRG REFRIG stands for refrigerated product In this settin...

Страница 6: ...t For best adjustment stream should hit basin approximately 6 5 165mm from bubbler 3 Water coming out of Bubbler continuously When this occurs at the end of the compressor cycle turn the cold control...

Страница 7: ...creen and rinse thoroughly with water Insert screen back into solenoid valve and screw cap on Make sure the o ring is placed properly 45392C Bubbler Nipple Basin 1000004123 1000004123 Inspect Bottle F...