background image

97296C (REV. L - 4/05)

EDFP220RC       EDFPVR220RC

Installation/Care/Use Manual

Composite Fountain with FLEXI-GUARD

®

To assure you install this model easily and correctly,
PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE
INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH
PLUMBING, ELECTRICAL AND OTHER APPLICABLE CODES. After installation, leave
these instructions inside the fountain for future reference.

IMPORTANT! INSTALLER PLEASE NOTE.

THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO
WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY
OCCUR AWAY FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK
INTO A FOUNTAIN, CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN
INCREASE IN THE METAL CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING
THE PROPER MATERIALS AS INDICATED. ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER
SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING
PLUMBING SYSTEM.

IMPORTANT

ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON

FIG. 2

FIG. 1

NOTE: WATER FLOW

DIRECTION

BUILDING WATER

INLET

SERVICE STOP
(NOT FURNISHED)

1/4" O.D. TUBE
WATER INLET
TO COOLER

3/8" O.D. UNPLATED
COPPER TUBE CONNECT
COLD WATER SUPPLY

Installer

Содержание EDFP220RC

Страница 1: ...MMON PROCEDURE THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCURAWAY FROM THE BUILDING THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTOAFOUNTAIN CREATINGAN ELECTROLYSIS WHICH CAUSESAMETALLIC TASTE ORAN INCREASE IN THE METAL CONTENT OF THE WATER THIS CONDITION ISAVOIDABLE BY USING THE PROPER MATERIALSAS INDICATED ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO ELECTRICAL...

Страница 2: ...97296C REV L 4 05 EDFP220RC EDFPVR220RC FIG 3 PAGE 2 LEGEND A 3 8 O D UNPLATED COPPER TUBE CONNECT SHUT OFF VALVE BY OTHERS B WATER OUTLET 1 1 4 O D DRAIN STUB OUT FROM WALL 1 25mm ...

Страница 3: ...adjustment will raise stream height and counter clockwise will lower stream height For best adjustment stream should hit basin approximately 6 1 2 165mm from bubbler 8 Replace bottom access panel to fountain using the screws provided Tighten securely CAREANDMAINTENANCEOFELKAYCOMPOSITEFOUNTAINS 1 Elkay composite fountains provide an extremely durable nonporous surface which resists staining Care is...

Страница 4: ...8 18 VR MODEL ONLY NUT REGULATORMOUNTING NIPPLE ASSEMBLY POLYTUBING CUTTO LENGTH 40322C 55998C LK464 15005C 27635C 40045C 45391C 45662C 45738C 50986C 56011C 56087C 55996C 56046C 61313C 75672C 70682C 75534C 75553C 75554C 98118C 75575C 70012C 45736C 15029C 56092C 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 NS DESCRIPTION FIG 6 NOTE WHENINSTALLINGREPLACEMENT BUBBLERANDPEDESTAL T...