 Owners Manual

4595 Freeze Resistant Pedestal Barrier Free Stone Fountain

4595FR Fountains are among the easiest to install Fountains on the market today. To assure
you install these models easily and correctly, PLEASE READ THESE SIMPLE INSTRUCTIONS
BEFORE STARTING THE INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE
WITH PLUMBING, ELECTRICAL, AND OTHER APPLICABLE CODES. After installation, leave
these instructions with the Fountain for future reference.

IMPORTANT

ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON

IMPORTANT

THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER LINES IS A
COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE BUILDING. THIS
GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREATING AN ELECTROLYSIS WHICH CAUSES A
METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING
THE PROPER MATERIALS AS INDICATED. ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE OF
PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM.

INSTALLER

STOP!

PLEASE READ THE FOLLOWING

INFORMATION.

• INSTALLATION INSTRUCTIONS FOR THE 4595FR FTN.

WITH 97482C DUAL VALVE CONTROL ASSEMBLY ARE
LOCATED ON PAGES 2 - 5.

• INSTALLATION INSTRUCTIONS FOR THE 4595FR FTN.

WITH SANITARYFR2 VALVE ARE LOCATED ON PAGES
6 - 12.

Содержание 4595FR

Страница 1: ...UNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE COMPUTERS ETC TO WATER LINES IS A COMMON PROCEDURE THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE BUILDING THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTOAFOUNTAIN CREATINGAN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE ORAN INCREASE IN THE METAL CONTENT OF THE WATER THIS CONDITION ISAVOIDABLE BY USING THE PROPER MATERIALS AS INDIC...

Страница 2: ...ible cap may be removed for servicing the valve 5 We recommend that the top of the column be flush or slightly above the top height of the concrete pad 6 You should test the unit before you backfill Simply blow on the clear small diameter tubing A steady stream should flow from the braided tubing line When air pressure is removed from the clear tubing the water stream should stop 7 Once you have t...

Страница 3: ... PANEL B REMOVABLE BOTTOM COVER C 1 PVC DRAIN D PRESSURE FITTING 1 1 4 x 3 4 E CONNECTOR 1 1 4 TO 1 1 4 F 1 1 4 DRAIN TUBE G AIR CONTROL LINE H 1 4 WATER LINE J CONNECTOR FOR AIR CONTROL LINE SITE PREPARATION DETAIL FOR THE 4595FR FTN WHEN USING 97482C DUAL VALVE CONTROL ASSY FIG 1 ...

Страница 4: ...STRUCTIONS FOR INSTALLING 97482C DUAL VALVE CONTROL ASSY 1 Prepare trench for water supply and waste drain lines if required by local codes The hole should be deep enough to accommodate the PVC column and 5 cubic feet of porous fill large broken rock Additional porous fill may be required due to local ground conditions See Site Preparation Detail below 2 Lay drain lines and water supply lines Prov...

Страница 5: ...1 8 Cut To Length To Actuator Allen Wrench 1 2 3 4 5 6 7 8 9 10 A 10 B 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 NS NS NS FOR PARTS CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1 800 323 0620 PRINTED IN U S A Includes items 30 31 32 100147140560 100322740560 101449542550 101570540560 15013C 110544942550 110868642550 160270508640 170705042830 400942308640 98287C 40250C 45403C 4547...

Страница 6: ...onditions Cut the PVC column to fit desired bury depth Set PVC column in excavating pit 2 Lay drain lines and water supply lines Provide service shut off valve for maintenance Flush the water supply line before attaching to the shut off valve Other Notes The details on the attached pages show a suggested installation method Depending on the climate and environmental conditions the suggested instal...

Страница 7: ...PAGE 7 97461C Rev SIC 1 11 4595FR_FTN LK4595FR_FTN LK4595SFR_FTN SUGGESTED SITE PREPARATION DETAIL FOR THE 4595FR FTN WHEN USING THE SANITARYFR2 VALVE FIG 1 ...

Страница 8: ...SFR_FTN SUGGESTED SITE PREPARATION DETAIL FOR THE 4595FR FTN WHEN USING THE SANITARYFR2 VALVE LEGEND A ACCESS PANEL B REMOVABLE BOTTOM COVER FIG 2 1 1 2 DRAIN TUBE SUPPLIEDWITHFTN AIR GAP ASSY SUPPLIED WITH VALVE 1 1 2 DRAIN TUBE SUPPLIEDBYINSTALLER Detail A ...

Страница 9: ...o the air Step 3 Insert the 1 4 O D tube s Labeled E F into the 1 4 union s provided with valve assembly Insert the 1 4 O D water lines coming from the fountain s into union s Trim any excess length Step 4 Insert the 1 4 O D tube Labeled G into the air gap assembly Step 5 Secure the 1 4 O D tube Labeled H to the waste line assembly This line is a vent line and should be open to the air FOUNTAINCON...

Страница 10: ...PAGE 10 97461C Rev SIC 1 11 4595FR_FTN LK4595FR_FTN LK4595SFR_FTN FIG 6 16 6 3 2 4 12 15 7 17 7 14 7 5 13 7 SEE DETAIL B DETAIL B 8 8 8 8 15 17 FIG 4 FIG 5 Stream Height Adjustment ...

Страница 11: ...2C 75653C 70683C 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 NS PARTNO Hex Nut 3 8 16 Bracket Regulator Holder Hex Nut 1 5 16 Dual Valve Regulator Holder Regulator Nut Poly Tubing 1 4 Cut To Length Poly Tubing 1 8 Cut To Length Canister Trap Adaptor 1 1 2 Air Gap Assy Fitting 1 2 Union w Strainer Regulator Fitting Elbow 1 4 Stem x 1 4 Tube Fitting Connector 1 4 x 1 4 NPTF Fitting Elbow 1 4 x 1...

Страница 12: ...d double check that the valve is positioned fully at the bottom of the PVC column Cap the PVC column Continuous Bubbler Flow Insure that push button is not obstructed and springs back to normal position Remove four screws which secure plastic diaphragm block to valve body Pull plastic and rubber diaphragm assembly out of valve body Locate tiny hole in rubber diaphragm just under lip of plastic par...

Отзывы: