background image

ELK-319PIRC  Wireless Ceiling Mount PIR Sensor

Description

The ELK-319PIRC is a Supervised, Wireless 360° degree 

PIR (passive infrared) Motion Sensor designed specifically for 

ceiling mount applications.

When  motion  is  sensed  in  the  field  of  view  the  sensor  will 

transmit  a  violation  (trip)  signal  to  the  panel.   Additionally  

transmitted signals include: tamper, hourly supervisory, and 

low battery (as needed). The sensor is powered by two (2) 

replaceable 3VDC lithium batteries.

This sensor is compatible with Elk’s 319MHz Receivers/Panels 

as well as many other panels that operate on the 319.5MHz 

Frequency and adhere to the ITI/Interlogix protocol.  

Specifications

RF frequency:  319.5 MHz 

Compatibility: 

ELK-319 Receivers/Panels & other panels  

 

that operate on the 319.5MHz Freq. and 

   

adhere to the ITI/Interlogix protocol 

Battery type:  

Two (2) 3VDC lithium battery

   

(Panasonic CR123)

Tamper Switch:  Sealed dome-contact

Sensitivity: 

Selectable 2 event or 3 event

Operating Temp: -40 to 131°F (0 to 49°C) 

Storage Temp:  -30 to 140°F (-34 to 60°C) 

Max. Humidity:   90% Relative Humidity non-condensing 

Dimensions      2.95” Diameter x 1.39” depth

Programming (Enrollment)

The following is a general guideline for programming (enrolling) 

a  sensor  into  the  receiver  or  panel.  For  more  extensive 

instructions please refer to the receiver or panel instructions. 
1.  Place the panel into the Program mode. 

2.  Proceed to the WIRELESS SETUP menu. 
3.  Select the appropriate zone/sensor location number. 
4.  When the panel prompts to trip the sensor do the following: 

•    Separate sensor from the mounting base
•    Remove battery pull tabs (if present) to power the sensor
•    The panel should acknowledge sensor has been learned 

by a display on the keypad and/or audio alert (depending 

on the panel).  If enrollment does not succeed repeat the 

process by removing and reinstalling the battery OR try 

pressing and releasing the tamper plunger.

5.  For additional sensors of this type repeat the above process.  

Proceed to the zone programming to assign each sensor’s 

zone definition.  

IMPORTANT: Set the Zone Loop as “1” for 

this sensor.

6.  Exit the panel Program mode when finished.

Coverage Pattern and Mounting Height

Coverage pattern is dependent on the mounting height of 

the sensor.  If required areas can be masked off to prevent 

unwanted detection in the 360° field of vision.  

Mounting Height

Detection Area

8 ft

14 ft

10 ft

25 ft

12 ft

40 ft

TM

  Interlogix is a registered trademark belonging to United Technologies.

Lo Sensitivity - 3 event - place jumper on top two pins
Hi Sensitivity - 2 event - place jumper on bottom two pins
LED - jumper installed across pins for visual walk test

Installation Guidelines

Sensor is designed for ceiling mount applications that provide 

a 360° field of view. 

•   Do not install on a sloped ceiling/surface.
•   Maximum mounting height is 12ft.
•   Do not mount outdoors

20

 

(6)

    

12.5

 

(4)

   

6.5

 

(2)

    

0

   

6.5

 

(2)

   

12.5

 

(4)

   

20

 

(6)

                              

Diameter

   

ft

  

(m)

Height

  

ft

 

(m)

     

8

 

ft

 

(2.4m)

      

10

 

ft

 

(3m)

   

12

 

ft

 

(3.6m)

Dia.

  

ft

 

(m)

20

 

ft

 

(6m)

12.5

 

ft

 

(4m)

6.5

 

ft

 

(2m)

0

6.5

 

ft

 

(2m)

12.5

 

ft

 

(4m)

20

 

ft

 

(6m)

Tamper

Sensitivity

J70

S2

LED

Lo
Hi

All manuals and user guides at all-guides.com